The Honeywell ControlEdge™ HC900 Process and Safety System is a fully field-proven system for process control and safety applications,
with over 15,000 installations throughout the world.
Its SIL-2 certification means it can be used in a variety of safety application such as burner management systems (BMS),
emergency shutdown systems (ESD), fire & gas monitoring, pipeline monitoring, spill prevention, tunnel ventilation, etc.
Failsafe
All ControlEdge 900 Platform I/O modules support a user specified failsafe value (analog) or
state (digital) that the module outputs or inputs will assume if communication
between the controller and the module is interrupted.
Output modules are also disabled if the controller fails to start.
Module diagnostics are not initiated if the control strategy does not call for the inputs or outputs on the modules to execute.
Failsafe is restricted to de-energize in safety applications.
Overview
The Honeywell ControlEdge HC900 Controller is an advanced loop and logic controller offering a modular
design sized to satisfy the control and data acquisition needs of a wide range of process equipment.
Insert and Removal of I/O under Power
For ease of maintenance, the ControlEdge HC900 controller supports removing and inserting I/O modules
from the module rack without removing power from the controller.
Each module is sensed for validity by the controller and auto-configured on insertion.
Other Modules
In addition to I/O, the following modules are available.
Scanner 1 module, single port (p.31)
Scanner 2 Module, dual port (p.32)
Universal AC Power Supply, 60W (p.4)
Power Supply 24VDC, 60W (p.4)
Redundant Switch Module (p.33)
Power Status Module (p.33)
Remote Terminal Panels
Optional DIN rail mounted Remote Terminal Panels (RTPs) are available for use with pre-wired cables to reduce installation time and labor expense.
Four types of RTPs are available: analog inputs, relay outputs, redundant I/O and other I/O modules.
Three cable lengths are also available to match hardware to installation variations.
Analog inputs RTPs include transmitter shunt resistors and transmitter power terminals with individual circuit fuses.
The Relay Output RTP includes a fuse and power disconnect switch for each output.
All the three types of RTP panels also switch power to allow module removal and installation under controller power.
Introduction
The New 900 Control Station (900CR series) operator interface from Honeywell compliments the
ControlEdge HC900 Process & Safety Controller with a unique combination of predefined display
features and custom display development tools to deliver ease of use and high flexibility in an efficient and affordable package.
The color display and finger touch user interface enhances process monitoring while simplifying online controller changes.
The Station Designer software used to configure the interface works in conjunction with
the ControlEdge HC900 Controller configuration software to automatically build a Control
Station database that exactly matches the unique, user configured, controller database.
This highly integrated operation eliminates the time-consuming task of assigning controller communication
register addresses to the operator interface parameters used to build displays.
The standard database of the Control Station allows all available controller tags to be
imported without restriction or costly price adders, eliminating the risk of running out of tag resources in the middle of your project.
The hardware of the 900 Control Station is designed to handle tough industrial environments
with polycarbonate case design and water tight, type 4X/IP66, front bezel assembly. and active alarm status.
The new 900CR is the perfect solution for applications that require the operator to monitor and control more than just a single device.
With up to four serial ports and two Ethernet ports,
these HMI displays can connect to multiple serial and Ethernet devices simultaneously, including variable frequency drives, bar code scanners, etc.
Terminal Blocks
20-screw Barrier style and Euro style terminal blocks are available for use with all ControlEdge HC900 I/O Modules.
Red terminal blocks are used for high voltage connections for added safety while black terminal blocks are used for low voltage connections.
A 36-terminal Euro style block is available with the 16 AI, the 8 and 16 AO as well as the 32 DC DI and 32 DC DO module types.
Other advantageous products on sale are listed below:
Honeywell Low Votage RTP Cable (5.0M 16.4ft.) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-L150
Honeywell High Voltage RTP Cable (1.0M 3.28ft.) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-H110
Honeywell Digital In 120/240VAC 125VDC (16ch Iso) 900TCK-0001
Honeywell Digital Output Relays ( 8 channel) 900TER-0001 900TBR-0001
Honeywell Digital Output 24VDC (16 Channel) 900TEK-0001 900TBK-0001
Honeywell LV RTP Cable (32/16 channel) (2.5M 8.2ft) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-3325
Honeywell LV RTP Cable (32/16 channel) (5.0M 16.4ft) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-3350
Honeywell 8 ch A/O RTP Cable (1.0M 3.3ft) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-B910
Honeywell 8 ch A/O RTP Cable (2.5M 8.2ft) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-B925
Honeywell 8 ch A/O RTP Cable (5.0M 16.4ft) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-B950
Honeywell Filler Block Terminal Cover 900TNF-0101
Honeywell Shield Terminal Strip (package of 2) 900TSS-0001
Honeywell Terminal board jumpers (10 two pos jumpers) Note 4 900J02-0001
Honeywell Terminal board jumpers (10 ten pos.jumpers) Note 4 900J10-0001
Honeywell Analog Input (8 channel) 900TEK-0001 900TBK-0001
Honeywell Analog Output 0 to 20mA (4 channel) 900TEK-0001 900TBK-0001
Honeywell Analog Output 0 to 20mA (8 channel) 900TCK-0001
Honeywell Analog Output 0 to 20mA (16 channel) 900TCK-0001
Honeywell Digital Input Contact type (16 channel) 900TEK-0001 900TBK-0001
Honeywell Digital Output 120/240 VAC (8 channel) 900TER-0001
Honeywell 900RTC-L010 Remote Terminal Low Voltage Cable Assembly 1.0 meters long
Honeywell High Voltage RTP Cable (2.5M 8.2ft.) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-H125
Honeywell High Votage RTP Cable (5.0M 16.4ft.) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-H150
Honeywell LV RTP Cable (32/16 channel) (1.0M 3.28ft) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-3310
Honeywell Digital Input 24VDC (16 channel) 900TEK-0001 900TBK-0001
Honeywell Digital Input 120/240 VAC (16 channel) 900TER-0001 900TBR-0001