Managing operational risks with confidence
The Tricon fail-safe and fault-tolerant controller is used extensively in high-hazard industries
where safe operations are critical and reliable operation is paramount.
In particular, the Tricon system is the only commercial off-the-shelf controller approved by
the Nuclear Regulatory Commission for Nuclear 1E applications.
Our safety and critical control solutions are supported by a dedicated team of TÜV-certified FunctionalSafety Experts and Engineers,
deplo yed globally, ensuring that expertise is always available where and when required.
A powerful, scalable design with assurance of continuous operation,
the Tricon system complies with international standards such as IEC61508 and fulfills
the requirements for applications such as Emergency Shutdown (ESD), Fire and Gas Protection (F&G),
Burner Management (BMS),High Integrity Pressure Protection (HIPPS), and Turbo Machinery Control (TMC).
The redundant high-availability architecture provides a flexible,robust, reliable,
and powerful solution that is ideal for clients looking to achieve environmental and safety excellence.
Tricon Key capabilities
• TÜV-certified for SIL3 applications to international standard IEC61508
• High-availability architecture for continuous operation
• Fault-tolerant architecture for continuous operation even under fault conditions
• Choice of form factors
• Online module replacement ensures continuous operation and plant availability
• Online upgrade without process interruption
• Direct Integration with Foxboro®Evo process automation system
• Easily integrated with all major distributed control systems
• ISA Secure EDSA Level 1 right out of the box
• Works in both centralized and distributed applications
• HART protocol pass through to Asset Management Systems
• Fast program cycle time from 10 mS
• 1 mS SOE Digital Input
• Choice of termination options — Direct and ETP
• Expertise available from our TÜV-certified Functional Safety Experts and Engineers
• Continually current technology
• Comprehensive family of I/O modules
TRICONEX TRIPLE MODULAR REDUNDANCY
Tricon operation is based on the principle of safety and high plant availability, which identifies and
compensates for failed control system elements and allows on line replacement while continuing
its assigned task without interrupting the controlled process. Fault Tolerance is achieved through TMR technology.
TMR employs three isolated, parallel control systems and extensive diagnostics integrated into one
system. The Tricon system uses two-out-of-three (2oo3) voting to provide high integrity, error-free,
uninterrupted process operation with no single point of failure. Setting up applications is simplified
with the Tricon, because the TMR system operates as a single control system from the user’s point of
view. The extensive diagnostics are inherent and transparent to the programmer.
Use of the Tricon continues to expand into new industries and applications as customers require
increased system safety and/or high availability. Today, Invensys has delivered and installed Triconex
safety system solutions in over 70 countries, providing increased safety and high process uptime.
Operating principals
• Fail Safe — De-energize to trip
• Energize to trip
• Safe, available, secure
Communications
• SIL3 Peer to Peer (254 Nodes)
• OPC DA and A&E (embedded server)
• Modbus TCP/IP Master and Slave
• Modbus Serial Master and Slave
• TSAA
• Copper and Fiber Optic
• ISA Secure EDSA Level 1
Applications
• Emergency Shutdown (ESD)
• Burner Management Systems (BMS)
• Fire and Gas Systems (F&G)
• High Integrity Pressure Protection systems (HIPPS)
• Turbo Machinery Controls (TMC)
• Control of critical applications
A powerful, scalable design with assurance
of continuous operation, the Tricon system complies with international safety
standards such as IEC61508 and fulfils the requirements for applications such as
Emergency Shutdown (ESD), Fire and Gas Protection (F&G), Burner Management
(BMS), High Integrity Pressure Protection (HIPPS) and Turbomachinery Control
(TMC). The redundant high availability architecture provides a flexible, robust,
reliable and powerful solution that is ideal for clients looking to achieve
environmental and safety excellence.
The Tricon system is a must for clients who need to maximize the safety and
performance of their assets. If you are challenged with reducing investment and
lifecycle costs, meeting new safety standards, combating tough competitive
pressure in your markets as well as the welfare of your employees and the
environment, then the Tricon system is designed for you.
Related Items we have in stock
Triconex Model 3351 Analog Input Module
Triconex Model 2351Analog lnput Baseplate
Triconex Model 2352 Analog input External Termination Panel Baseplate
Triconex Model 9764-310 RTD/TCIAl Termination Panel
Triconex Analog Output Modules
Triconex Model 3481 Analog Output Module
Triconex Model 3482 High-Current Analog Output Module
Triconex Model 2481 Analog Output Baseplate
Triconex Digital lnput Module
Triconex Model 3301 Digital Input Module
Triconex Model 2301 Digital Input Baseplate
Triconex Digital Output Module
Triconex Model 3401 Digital Output Module
Triconex Model 2401 Digital Output Baseplate
Triconex Model 2402 Digital Output Baseplate
Triconex Pulse Input Module
Triconex Model 3381 Pulse Input Module
Triconex Model 3381 Pulse Input Module Specifications
Triconex Model 2381 Pulse Input Baseplate
Triconex Solid-State Relay Output Module
Triconex Model 3451 Solid-State Relay Output Module
Triconex Model 2451 Solid-State Relay Output Baseplate
Triconex LO Extender Modules
Triconex Model 2281 LOExtender Module Kit
Triconex Model 2291 lO Extender Module Kit
Triconex Model 2292 VO Extender Module Kit
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved