Different versions of the MPC4 card
There are different versions of the MPC4 card, including “Standard”, “Circuit Independent”
and “Secure” (SIL) versions.
In addition, some versions have a conformal coating applied to the card's circuitry to provide additional
environmental protection against chemicals, dust, moisture and temperature extremes.
Both the “Standard” version and the “Safety” (SIL) version of the MPC4 card are certified to
IEC 61508 and ISO 13849 for use in functional safety environments such as SIL 1 according
to IEC 61508 and ISO 13849-1 for PL c.
The “standard” MPC4 card is the original version and supports all functions and processing modes.
The “standard” MPC4 is suitable for safety systems using the VM600 rack.

Processed dynamic (vibration) and velocity signals are available as analog outputs
at the rear of the rack (on the front panel of the IOC4T).
Voltage signals (0 to 10 V) and current signals (4 to 20 mA) are available.
The MPC4 performs self-tests and diagnostic procedures at power-up.
In addition, the card's built-in “OK system” continuously monitors the signal level provided
by the measurement chain (sensors and/or signal conditioners) and indicates any problems
caused by broken transmission lines, faulty sensors or signal conditioners.
An LED on the front panel of the MPC4 indicates whether a processing or hardware error has occurred.
A further six LEDs, one for each input channel, indicate whether the OK system has detected
a fault and whether an alarm has occurred on the channel.
There are three versions of the MPC4 card: the “standard” version, the “circuit independent” version,
and the “safe” (SIL) version, all of which use the appropriate IOC4T input /output cards as card pairs.
Features
System isolation
The VM600Mk2 uses a single type of card (MPC4Mk2) for monitoring and condition monitoring.
However, these functions are tightly segregated to ensure API 670 compliance and reduce costs.
A separate (optional) XMV16 condition monitoring card is available for applications
with a large number of channels.
High channel density
The standalone VM600Mk2 protection card has 4 input channels, but each VM600 can be expanded
to a maximum of 48 input channels Mk2 racks, allowing vibration protection to be
extended to the most demanding rotating machinery.
Advanced Monitoring
The stand-alone VM600Mk2 condition monitoring card offers 16 dynamic channels and 4 tachometer channels,
which can all be independently configured to provide unrivaled accuracy and reliability.
| TRICONEX AI3351S2 Analog Input Module |
| UNIOP ETT-VGA-0045 | Operator Interface Panel |
| UNIOP ETT-VGA Touchscreen Human-Machine Interface Monitor |
| UNIOP TCM08A Data Transmission Communication Card |
| ETOP306 UniOP eTOP 300 Series HMI touch panel |
| Vibro-meter vmf-IOCN 200-566-101-013 200-566-000-112 communication interface card |
| Vibro-meter 204-040-100-012 VM600 system rack |
| Vibro-meter VM600-ABE040+204-040-100-011 measurement module |
| Vibro-meter VM600 CMC16 PNR200-530-022-014 Communications Management Controller |
| Vibro-meter VM600 RPS6U PN200-582-500-013 Power Supply Module |
| Vibro-meter VM600 IOC16T PNR200-565-000-013 Industrial Control Module |
| Vibro-meter VM600 IOCN PNR200-566-000-112 Industrial Control Module |
| Vibro-Meter VM600 PNR200-570-000-111 Industrial Monitoring Module |
| Vibro-meter VM600 IOC4T | PNR200-560-000-111 | input/output card |
| Vibro-meter MPC4 200-510-078-115 Meggitt Sensing Systems |
| Vibro-meter 200-510-111-035 MPC4 mechanical protection card |
| vibrom-meter MPC4 200-510-076-115 Four-channel machine protection controller |
| vibrom-meter VM600 MPC4 machinery protection and condition monitoring module |
| Vibro-meter MPC4 200-510-071-113 machinery protection card |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved