Emerson Ethernet I/O Card (EIOC) Supported Industrial Ethernet Protocols

From:Emerson | author:Mr.Chen | Time :2024-12-18 | 2431 view: | 🔊 Click to read aloud ❚❚ | Share:

Supported Industrial

Ethernet Protocols:

Modbus TCP Interface

The Modbus TCP interface will support Modbus data

sources such as PLCs, MCCs, analyzers and similar devices

communicating Modbus TCP. The Modbus TCP interface is a

Modbus Client reading and writing data from/to Modbus Server

devices. The Modbus server devices can be Modbus TCP devices

or Modbus serial devices using a Modbus TCP gateway.

The Modbus TCP interface supports the following types of

data access:

„ Reading input data from Modbus Coils, Discrete Input,

Holding Registers, and Input Registers.

„ Writing output data to Coils and Holding registers.

All reads will be performed periodically and outputs will be

sent when they are written.

EtherNet /IP

The EtherNet/IP protocol allows data sources such as

PLCs, Intelligent Field Devices (IFDs), variable-speed drives,

MCCs, and analyzers; as well as other devices communicating

EtherNet/IP to connect directly in to DeltaV via the EIOC.

The EtherNet/IP interface will support connections for

both implicit and explicit messaging to allow access to both

Class 1 and Class 3 EtherNet/IP I/O adapters. Redundancy with

EtherNet/IP Class 1 Implicit and Class 3 Explicit messaging

for control (sending outputs to the devices) require special

considerations due to exclusive owner communications defined

by the protocol. Please refer to the DeltaV System Planning

Guide for more information. Class 3 PCCC and UCMM with

Logix tags message classes are also supported.

IEC 61850 (MMS)

The IEC 61850 MMS interface will allow data from Intelligent

Electronic Devices (IEDs) such as motor protection relays,

motor starters, motor control centers, switchgear, and similar

MMS-based devices to be integrated into DeltaV. The MMS

interface will be a client reading and writing data from/to the

Intelligent Electronic Device which acts as the server.

The EIOC only supports reading and writing of real time

signals using this protocol. Reading historical data or

Goose applications are not supported.

OPC UA Client

The OPC UA Client in the EIOC provides native client

implementation of a Data Access profile (real time data)

compliant with OPC UA version 1.03. The OPC UA client will

read and write up to 30,000 real time signals coming from

up to 64 OPC UA servers.

EtherNet/IP Control Tag Integration protocol

The EtherNet/IP Control Tag Integration protocol utilizes

EtherNet/IP Class 3 messaging to provide integration with

tag-based PLC data sources. Referencing data by tag name

eliminates the need for register mapping. Read or write up

to 10 signals per tag, and up to 2000 tags per EIOC for a total

of 20,000 signals. The EtherNet/IP Control Tag Integration

protocol supports reading string type signals and read/write

of arrays up to 64 elements each (max 100 arrays per EIOC).

The EtherNet/IP Control Tag Integration protocol supports

integration with ControlLogix and CompactLogix PLCs

utilizing tags.

Parallel Redundant Protocol (PRP)

PRP is a network protocol standard for Ethernet that provides

seamless failover against failure of any network component.

Therefore, it is a great solution when high availability and short

switchover time is required (e.g. electrical monitoring using

IEC 61850 MMS). PRP allows for communications in Primary and

Secondary ports of the Ethernet Device Network in the EIOC to

happen at the same time. This means that a device connected

to the Ethernet Device network is getting the same information

at the same time, through different network paths. In case of

failure in one of the networks it basically provides a zero-time

to recovery (no time to switchover) and eliminates any single

point of failure in a redundant Ethernet Device Network.

PRP is independent of the application-protocol and can be

used by most Industrial Ethernet protocols. In the EIOC,

PRP is an optional feature than can be enabled at the port level

and is available with all the protocols supported in the EIOC.

When enabled, PRP runs on top of the protocol that is selected

at that time.

For PRP to work properly, the Ethernet Devices connected to

the redundant network needs to support PRP natively as well.

If the devices do not support PRP natively, then a RedBox must

  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch
  • Eaton 5884-1400 6-Digit Dual Preset Control W/ Batch Control
  • Eaton 1023843 Power Circuit Board 94V
  • EATON ES4P-221-DRXD1 24VDC NSMP
  • Eaton DH222NWK heavy duty fusible safety switch
  • Eaton Touch Panel 10.1 inch XV-303-10-C00-A00-1C
  • Eaton RDF200J-3 Bussmann series RDF fused rotary disconnect switch
  • EATON CORPORATION A200M2CACD A200 NEMA Motor Control
  • Eaton SPD160208Y3J Surge Protection Device
  • EATON CORPORATION SPD160208Y3K SURGE SUPPRESSOR
  • EATON DILM400/22 (RA250) 200KW Coil Voltage/Coil 110-250V 40-60Hz/DC
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • EATON CORPORATION D820MPM HMI
  • EATON PXG900 Power Xpert Insight Gateway 900
  • Eaton Durant 5882-7 Digital Counter loc2D3
  • EATON AXCELIS 1220-0012-0002 DISK VACUUM DI CONTROLLER
  • Eaton 1383B-6501 80 Series Photoelectric Sensor Head
  • Eaton FDC2100L Series C molded case switch
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • Eaton FD3200L circuit breaker
  • Eaton Touch Screen Control Panel X-152-D6-10TVRC-10
  • EATON VICKERS EEA-PAM-523-A-32 02-326001 POWER AMPLIFIER
  • Saacke Seavis HMI 03 EATON XV-102-B6-35TQR-1AL-PLC HMI Touch Panel
  • EATON MTL E05016 DIGITAL INPUT EUROCARD E05516-2134
  • Eaton HFD3150 3P 150A 600VAC Circuit Breaker
  • Eaton HMIVU06CUNB1 HMi Operator Interface, RS-232, 5.6"
  • Cutler-Hammer/ Eaton Panelmate PowerPro 5785 with cables LCD monitor
  • Eaton D100CA40 40 I/O Micro PLC 115VAC Input Triac Output
  • EATON CUTLER HAMMER 66D2032GX1 MP-3000 PROTECTION RELAY
  • EATON R9L3200FJ Rotary Disconnect Switch
  • EATON CORPORATION E51CLT16PCU Switch
  • Aerotech Modular System Control Console
  • Aerotech TV Series Transformers
  • Aerotech TM5 Transformer Module (500 watts)
  • Aerotech TM3 Transformer Module
  • Aerotech UFM Noise Filter Module
  • Aerotech MFM10-2 Motor filter module
  • Aerotech MFM10-1 Motor filter module
  • Aerotech MPG Handwheel Pendant
  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3246-0000 | EtherCAT Terminal, 6-channel analog input, temperature
  • Beckhoff ELM3244-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3148-0000 | EtherCAT Terminal, 8-channel analog input, multi-function
  • Beckhoff ELM3146-0000 | EtherCAT Terminal, 6-channel analog input, multi-function
  • Beckhoff ELM3144-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckwith Electric M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-3919A Graphic Display Unit/ Human Machine Interface
  • Beckwith Electric M-4172 Digital Motor Bus Transfer System
  • Beckwith Electric M-3904B Remote Monitoring Module
  • Beckwith Electric M-3410A Intertie/Generator Protection Relay
  • Beckwith Electric B-1612 Adapter
  • Beckwith Electric B-1652 Adapter
  • Beckwith Electric B-1685 Adapter
  • Beckwith Electric M-2035 Analog to Digital Interface Module
  • Beckwith Electric B-2291 Digital Input Guard
  • Beckwith Electric M-2406 Recloser Control Adapter Chassis
  • Beckwith Electric M-3908 Universal Contact Input Adapter
  • Beckwith Electric M-3801D IPS Plot Software
  • Beckwith Electric M-7651A D-PAC
  • Beckwith Electric M-2979 Recloser Control Cabinet
  • Beckwith Electric M-0359 SYNCROCLOSER MOD512
  • Beckwith Electric M-2001C-6ELFA Tap Changer Controller Voltage Regulator Control
  • Beckwith Electric M-0124 TERMINAL BOARD ADAPTER PLATE 13 POS
  • Beckwith Pride M-0296C 3ph Programmable Relay
  • Beckwith Electric M-0388 Syncrocloser Check Relay
  • M-0170A AC Current Relay Beckwith Electric
  • Beckwith Electric Intertie Protection M-3520 Instruction Manual
  • M-3311 M-3311 7113 BECKWITH ELECTRIC TRANSFORMER PROTECTION RELAY
  • Pride M-0296b 3 phase Programmable Relay Beckwith Electric Co
  • Beckwith Electric M3310 Integrated Transformer Protection Panel
  • Beckwith M-0145 First Customer Protector
  • Beckwith Electric M-0296C 3 phase Programmabel Relay
  • Beckwith Electric M-0389 VOLTAGE VERIFIER
  • M-3425 M-3425-A1DE BECKWITH ELECTRIC GENERATOR PROTECTION RELAY SL
  • Beckwith Electric M-0420 Multifunction Relay Protection Module 48VDC
  • M-3430 M-3430M0D515 BECKWITH ELECTRIC GENERATOR PROTECTION RELAY
  • Beckwith Electric Tapchanger Control M-0067E
  • Beckwith M-2001D-6L4S20C0S0X Tap Changer Control Surplus
  • BECKWITH ELECTRIC M3425A-STD1 Generator Protection 85-280VDC
  • Beckwith Electric High Speed Sync-Check Relay #M-0245C Mod #22 (NIB)
  • Beckwith Electric M-7679 R-PAC