Products

The Bulletin 1402 Line Synchronisation Module (LSM) is designed to meet the needs of manufacturers of three-phase AC generators and power generation systems,

system integrators and users, or for applications where two three-phase systems need to be synchronised with each other.

The module provides the means for automatic synchronisation, load sharing and high-speed power system monitoring.

The Line Synchronisation Module (LSM) is a two-slot 1771 form factor module that fits into a standard Allen-Bradley 1771 I/O chassis.

It has three functions:

1. measures appropriate parameters from two three-phase systems and provides control and error signals for synchronised control of the engine governor.

2. provide an analogue output representing the ratio of the power supplied by the alternator to the alternator output rating;

To read an analogue input representing the ratio of the total system load to the total system capacity;

and provide an error signal to adjust the alternator for proper load sharing based on instantaneous load requirements.

3. act as a multi-function digital power monitor for the system.

These functions provide data and control signals that are transmitted to the PLC-5 through the 1771 backplane.

Synchronisation and Load Sharing Errors

In order to synchronise two three-phase systems without high transient energy transfer, the voltages, frequencies and phase differences of the two systems must match.

Kilowatt load sharing can be achieved by matching the ratio of the power system load to the system capacity to the ratio of the actual alternator power to the alternator power rating.

The LSM provides the following information so that the customer's system can achieve the necessary control operations.

- Voltage matching error (in units of 0.05%)

- Frequency matching error or slip (in 0.01 Hz)

- Synchronising bus and reference bus phase matching error (in 1 degree)

- Load sharing error (scalar between 0.000 and 1.000)

- Synchronisation status

- Frequency within limits

- Voltage within limits

- Phase within limits

- Synchronisation mode conflict fault

- Phase rotation mismatch fault (3-phase synchronisation mode only)

- No reference bus voltage fault

- No synchronised bus voltage present fault

- Reference bus overvoltage fault

- Synchronous bus overvoltage fault

Module Configuration

Before the LSM can perform its intended function, it must be configured by the user. The module is configured by providing the required data via a module block transfer.

Block transfer data can be entered manually into the PLC-5 or by using the 6200 version 4.4 I/O configuration software.The 6200 software can also be used to monitor module operation.

Installation

The Bulletin 1402 Line Synchronisation Module (LSM) should be installed in a Bulletin 1771 I/O chassis.

The chassis should be located in a dry, dirt-free environment, away from heat sources and extremely high electric or magnetic fields.

The module operates in an ambient temperature of 0 to 60 degrees C. The LSM is typically mounted in a local rack to maximise data transfer rates.

The device is classified as an open device and must be mounted in an enclosure to provide security during operation.

The enclosure selected should protect the LSM from atmospheric contaminants such as oil, moisture, dust, corrosive vapours or other airborne hazardous substances.

A steel enclosure is recommended to protect against EMI (Electromagnetic Interference) and RFI (Radio Frequency Interference).

The enclosure should be mounted in a position that allows the door to open fully. This allows for easy access to the LSM and associated component wiring.

When selecting an enclosure size, allow additional space for associated application equipment such as transformers, fuses, disconnect switches, master relays, and terminal blocks.

The LSM mounts in two slots in the Bulletin 1771 series B I/O chassis.

Mounting dimensions vary depending on the size of the chassis selected.

The LSM backplane power requirement is 1.1A (5V DC).

For proper and reliable performance, grounding recommendations specified by the Allen-Bradley PLC system must be followed.

  • A-B 20G11BC1K1JN0NNNNN PowerFlex Air Cooled 755 AC Drive
  • A-B 20P41AF452RA0NNN PowerFlex 452 A DC Drive
  • A-B 20GHAJC540JN0NNNNN PowerFlex Extra Tough 755 AC Drive
  • EPRO MMS6823 9100-00001-05 Displacement Monitor Module
  • GE LP-33 SERIES UPS DISPLAY & CONTROL PANEL LP33
  • GE CL06A300M IEC Contactor (50 Amp)
  • GE CR2962F2D Plugging Switch NIB
  • General Electric IC500A411DG2 Electrical Rectifier Semiconductor
  • GE IS200BICLH1AFE Interface Module 259B2431DB-G01 BICLH1A
  • General Electric 1253-0003-C4 Multilin Analog & I/O Board 369-A200
  • Ge Panametrics Crs-10-Mb Ultrasonic Flow Converter
  • GE PROPRIETARY IS215WEPAH2BB With IS210BPPCH1AD CONTROL BOARD
  • GE MULTILIN / 12P0-0001-P2 / Powerr Supply Board, 870500.DWG, 870501.DWG
  • GENERAL ELECTRIC PL19A129393G4 Auxiliary Receiver in Wall-mount Cabinet
  • GE CR306F002XAAA Nema-4 Coil 115-120V 60Hz 110-50Hz 600Vac Magnetic Contactor
  • General Electric 193x190bag02 ISOL P/S Board I93XI90BAG02 Computer board GE
  • GE Multilin / G6P3CH / Front Panel, G60 Generator Management Relay
  • GE MMY30-R1D26 DewPro MOISTURE TRANSMITTER
  • GE Drive Control Board 531X302DCIBDG2
  • General Electric SKLA36AT1200B Industrial Circuit Breaker 3Pole 600V / SRPK1200
  • GE CR2962E1A4 Plugging Switch 1600 RPM Max Speed Flange Mount
  • GE IS210AEACH1ABB Platine Card Sealed
  • GE EVEREST XLG3 Industrial Videoscope Sit 100-240V 50-60 Hz
  • GE DS215DMCBG1AZZ03B / DS200DMCBG1ALG board
  • 2H400489-0 REV 0 GE STATIC SENCITIVE BOARD A72 RPVM3
  • GE DM4E 1PC GE DM4E Ultrasonic Thickness Gauge Equipped with DA301 probe
  • GE DS200TCQAG1BED / DS200TCQAG1BED Analog IO Board
  • GE ENERGY PIB101C ANALOG I/O PIB MODULE PIB-101C
  • GE IC200CPUE05-HK VersaMax CPU Module IC200CPUE05
  • Ge Multilin F60 F6P3LA Feeder Protection System Brand
  • GE Intelligent IC695ALG112-DA RX3i 12 channel isolated analog input module
  • GE IS200WETBH1BBA Wind Turbine Control Panel PCB
  • GE Mark VI IS200HSLAH3A Genuine High-Speed Serial Link Interface Board
  • GE IS200TRLYH1BFD TERMINATION RELAY BOARD FOR MARK VI SYSTEM/JUA1221
  • GE XAMP-1-1-2-0 Adapter Converter With Enclosure
  • General Electric 1253-0002-C2 Multilin Upper Control Board 369-C100
  • GE Multilin 350 Feeder Protection Relay Controller Monitor Industrial Power
  • UR RHH / 12A0-0101-B4 GENERAL ELECTRIC MULTILIN POWER MODULE URRHH
  • GE MULTILIN / 12P0-0042-A5 / High-Density Input Board
  • GE MULTILIN / 12P0-0039-A1 / Digital Output Board
  • GE IS220UCSAH1A UCSA PWA Embedded Controller Mark VIe Gas Turbine Processor
  • GE RX3i PLC MODULE IC694MDL754-ED IC695MDL754
  • GE Multilin C60 Breaker Management Relay C60K03HKHF8LH6NM8LP6UUXXW7H
  • F31X139APMALG2 | GE Fanuc | Micro Application Board
  • GE HORNER ELECTRIC HE670ADC810D ANALOG INPUT MODULE
  • GE TRANSPORTATION LOCOTROL 7000069-910 REV. ZAE/D
  • GE Multilin / M6P3KH / Front Panel, M60 Motor Management Relay
  • GE 5CD124TP001B 2HP DC Motor 1750RPM 180V TEFC CD149ATC-PM
  • General Electric Ge RCC48 Lighting Controller Card
  • GENERAL ELECTRIC CR306F002XABA MAGNETIC STARTER
  • HE697THM160 GE Fanuc Series 90-70 Thermocouple Input Module, 16 Channel
  • GE 2298332 Digital Receiver and Filter II DRF2 2298333
  • GENERAL ELECTRIC DS3800NMEA1P1J CIRCUIT BOARD
  • GE 961529800 AVR Utilities Card S961529800 Prismic A30-M Controller
  • GE VMIVME 4140-000 VMEbus Analog Input I/O Module
  • GE VMIVME 3215-000 Computer module
  • GE IS215UCVFH2BB VMIVME-7650-83H 350-007650-83H C Control Module
  • GE VMIVME-7750 VMIVME-7750-834 350-027750-834 D Single Board Computer
  • GE V7668A-1310B0 350-9310007668-131020 Single Board Computer
  • GE IS220PRTDH1A 336A4940CSP6 Resistance Temperature Device
  • GE IS220PSCAH1A 336A4940CSP9 Serial Modbus Communication Interface Pack
  • GE SR745-W2-P1-G1-HI-A-L-R 745 Transformer Management Relay
  • GE SR745-W2-P1-G1-HI-A-L-R-E 745 Transformer Management Relay
  • GE WES13-3 2508-21001 Control Board Module
  • GE SR489-P5-H1-A20 Advanced Generator Protection
  • GE SR489-P5-LO-A20 Advanced Generator Protection
  • GE V7865-23003 350-9300007865-230003 M VMEbus Module
  • GE VME7865RC V7865-23003 350-9300007865-230003 M VMEbus Module
  • KEBA CU312/E Customized Controller
  • KEBA K2-200 CP253/W Input/Output Module
  • KEBA CU313 Large-Scale Complex Control Module
  • KEBA AR281 Industrial Control Module
  • KEBA CP450 Driver module
  • KEBA OP341/Y-1400 | Operator Panel
  • KEBA CP033/Y | Control Panel / Operator Interface
  • KEBA SI232 International Standard Field-Level Controller
  • KEBA PS244 Power Supply Module
  • KEBA DO321 | Digital Output Module
  • KEBA IP706 Industrial Control Module
  • KEBA CU313/B-SI/58626/09 Custom Processed Control Module
  • KEBA CU313A Large-Scale Complex Control Module
  • KEBA FB201 I/O modules
  • KEBA CP450/C Driver module
  • KEBA PS244/A Power Supply Module
  • KEBA EC100S High-Precision Industrial Controller
  • KEBA DI325 | Digital Input Module
  • Honeywell XNX-UTAV-RNIF1 XNX Universal Transmitter
  • Honeywell 51305896-200 NIM MODEM
  • HONEYWELL LG1093AA24 261A1812P012 FLAME SENSOR
  • HONEYWELL CC-TUIO41 Universal Input Output Module
  • Honeywell J-DIM00 Industrial Control Module
  • HONEYWELL 51403892-100 Carrier Channel Assy Assembly CC-MCAR01 Module
  • HONEYWELL 82408217-001 Analog Input Module
  • Honeywell J-MSC10 Output Circuit Control Module
  • Honeywell 51202329-606 I/O Link Header Cable
  • 51403519-160 K4LCN-16 Honeywell 16M LCN Processor Board
  • Honeywell 05704-A-0146 5704F Fire Card
  • Honeywell SC-UCMX01 51307195-175 Controller Module
  • Honeywell FC-PUIO01 TUIO11 Universal Safety I/O
  • Honeywell CC-TCNT01 51308307-175 Input/Output Module
  • Honeywell 51196655-100 ACX633 Switchmode Power Supply
  • Honeywell Fc-psu-uni2450U V1.0 Power Supply 24Vdc
  • Honeywell SC-UCMX01 51307198-175 Remote Terminal Unit
  • Honeywell 51196653-100-RP Controller Module
  • Honeywell FTA-T-14 Digital Input Module Brand
  • HIMA X-AI 32 02 32 channels 4 ... 20 mA Analog input module
  • HIMA X-D1 32 03 32 channels 48 VDC SlL 3 Digital input module
  • HIMA X-D1 32 02 32 channels 8.2 VDC Digital input module
  • HIMA X-D1 64 01 64 channels 24 VDC SlL 3 Digital input module
  • HIMA X-D1 32 04 32 channels 24 VDC SOE SIL 3 Digital input module
  • HIMA X-A1 32 51 32 channels 0/4 ... 20 mA Analog input module
  • HIMA F3 DI0 8/8 01 Remote l/Os HIMatrix systems
  • HIMA F2 DO 8 014 Extended Temperature Range
  • HIMA F3 A10 8/4 014 Extended Temperature Range
  • HIMA F35 034 Extended Temperature Range
  • HIMA AO 8 01 I/O modules HIMatrix systems
  • HIMA DI 32 014 Extended Temperature Range
  • HIMA 80107 Communication module for Ethernet (OPC server)
  • HIMA X-CPU 31 Processor module with system bus connection
  • HIMA X-BLK 01 Empty module
  • HIMA X-D1 32 05 32 channels 8.2 VDC Digital input module
  • HIMA X-D0 24 01 24 channels 24 VDC 0.5 A Digital output module
  • HIMA X-A0 16 01 16 channels 4 .. 20 mA Analog output module
  • HIMA C10 2/4 014 Extended Temperature Range
  • HIMA C10 2/4 01 I/O modules HIMatrix systems
  • HIMA GEH 014 Extended Temperature Range
  • HIMA D10 24/16 01 I/O modules HIMatrix systems
  • HIMA D124 01 I/O modules HIMatrix systems