• For Foundation™ fieldbus networks in hazardous areas
• Pre-assembled system components for up to 5 intrinsically
safe spur connections
• For assembly into user-specified field enclosure
• Spurs compatible with FISCO and “Entity-certified”
fieldbus instruments
• Ergonomic mechanical design
• Pluggable system components without “gas free” constraints
• Optional, integrated surge protection for trunk and spurs

The 9387-FB-R (5-spur) Open-frame redundant fieldbus barrier
provides intrinsically safe spur connections from a high-energy trunk, for
connection to suitably certified Foundation™ fieldbus H1 instruments.
The unit comprises pre-wired and assembled system components on
a stainless steel baseplate, for installation into a suitably certified field
enclosure. Connection facilities are provided for the trunk and spur
wiring, as well as all electronic modules needed to support a fully
working Fieldbus Barrier. In a typical application, an Ex e (increased
safety) certified field enclosure will be selected to allow installation
in a Zone 1 hazardous area; third-party approval of the enclosure and
contents is normally required.
The assembly uses duplicated fieldbus barrier modules in
a redundant configuration to achieve significantly higher system
availability than equivalent ‘simplex’ units. The 9387-FB-R may
therefore be selected for critical process applications where failure
of the Fieldbus Barrier would otherwise result in unacceptable
downtime or lost production. It is also ideal for use in Fieldbus Safety
Instrumented Function (SIF) networks in which nuisance trips cannot
be tolerated. Failure annunciation to the host control system is
provided by means of an integrated Foundation™ fieldbus device with
Digital Input Function Block capability.
In common with conventional fieldbus barriers, each intrinsically
safe spur is capable of supporting a FISCO or ‘Entity’ certified fieldbus
device located in a Zone 0 or 1 hazardous area. The short-circuit
protected spurs are galvanically isolated from the trunk and require no
protective ground connection in the field.
The 9387-FB-R redundant fieldbus barrier assembly is based on
the 9370-FB range of products, which are supplied as complete,
factory-assembled systems that do not require additional wiring or
complex ancillary components. The electrical and mechanical aspects
of this design have been integrated to provide the industry’s first
complete, ergonomic solution for ‘High Energy Trunk’ applications in
hazardous areas.
Uniquely, the key modular components of the system (Fieldbus
Barrier, Terminator and Surge Protectors) may be ‘hot-plugged’ by
design and without gas-clearance procedures or separate isolating
switches. This virtually eliminates the risk associated with hazardous
area maintenance activities, speeds module replacement and avoids
the need for specialist operator training. Further optional features
include pluggable surge protection components for the fieldbus trunk
and individual spurs.
The 9387-FB-R Fieldbus barrier assembly is bus powered and
requires no additional power supply in the field. When used with a
fieldbus host control system, power for the trunk may be provided by
redundant MTL power supplies.