Encoder Interface
The Ultra5000 main encoder feedback connector is CN2. The motor encoder
interface circuitry features include:
• 2.5 MHz maximum line frequency
• RS-485 serial channel for communicating with intelligent encoders
• Hall input for start-up commutation only
• Interpolation of sine/cosine encoders
All encoder signals are filtered using analog and digital filtering. The inputs
also include illegal state change detection. Refer to Figure 2.5 for a schematic
of the motor encoder inputs.
Hardware latches can be used for latching the encoder position based on an
index input or a digital input transition.
Auxiliary Encoder Interface
All encoder input signals (CN1B) are filtered using analog and digital filtering,
including illegal state change detection.
The input circuitry includes pull-up and pull-down resistors for compatibility
with single-ended and open collector signals, in addition to differential signals.
A single channel schematic of the auxiliary encoder interface is shown in the
figure below.
Understanding Serial Interfaces
The Ultra5000 contains two identical serial port connectors (Main Serial Port
CN3A and Auxiliary Serial Port CN3B) that implement the standard NRZ
asynchronous serial format, and support RS-232. RS-422. and RS-485
communication standards.
Standard baud rates include 1.200. 2.400. 4.800. 9.600. 19.200. and 38.400
baud. Data lengths of 7 and 8 bits are supported.
The connector pinout dedicates separate pins for the RS-232 and RS-422/
RS-485 signals, so that the communication standard can be changed by just
using a different cable. Refer to Figure 2.7 for the serial interface hardware
configuration.
Routing High and Low Voltage Cables
Be aware that when you connect and route power and signal wiring on a
machine or system, radiated noise from nearby relays (relay coils should have
surge suppressors), transformers, and other electronic drives can be induced
into motor or encoder feedback, communications, or other sensitive, low
voltage signals. This can cause system faults and communication problems. To
minimize the levels of radiated noise, route machine power and signal lines
separately.