Unpacking Modules
Each Ultra5000 ships with the following:
• One Ultra5000 drive
• One screwdriver
• One instruction manual (publication 2098-IN001B-EN-P)
• Two I/O connector plugs (14 and 28 pin)
Remove all packing material, wedges, and braces from within and around the
components. After unpacking, check the item(s) nameplate catalog number
against the purchase order.
System Mounting Requirements
There are several things that you need to take into account when preparing to
mount the Ultra5000:
• The Ultra5000 must be enclosed in a grounded conductive enclosure
offering protection as defined in standard EN 60529 (IEC 529) to IP55
such that they are not accessible to an operator or unskilled person. A
NEMA 4X enclosure exceeds these requirements providing protection to IP66.
• The ambient temperature of the location in which you will install the
Ultra5000 must not exceed 55° C (131° F).
• You must install the panel on a flat, rigid, vertical surface that won’t be
subjected to shock, vibration, moisture, oil mist, dust, or corrosive vapors.
• You need to maintain minimum clearances (refer to Figure 1.1) for proper
airflow, easy module access, and proper cable bend radius.
Refer to Appendix A for mounting dimensions, power dissipation, and
environmental specifications for the Ultra5000.
IMPORTANT If the cabinet is ventilated, use filtered or conditioned air to
prevent the accumulation of dust and dirt on electronic
components. The air should be free of oil, corrosives, or
electrically conductive contaminates.
Transformer Sizing
The Ultra5000 does not require isolation transformers. A transformer may be
required, however, to match the voltage requirements of the controller to the
available service. To size a transformer, the power output (KVA) of each axis
must be known. This can be derived by calculating the horsepower for each
axis and converting that horsepower into units of watts. If you are supplying
power to more than one motor and an Ultra5000. simply add the KW ratings
together from each calculation to get a system KW total.
Definitions:
KW = power or real power
KVA = apparent power
Mounting Your Ultra5000
Drive
The procedures in this section assume you have prepared your panel and
understand how to bond your system. For installation instructions regarding
other equipment and accessories, refer to the instructions that came with each
of the accessories for their specific requirements.
To mount your Ultra5000 drive:
1.Layout the positions for the Ultra5000 and accessories in the enclosure.
Mounting hole dimensions for the Ultra5000 are shown in Appendix A.
2. Attach the Ultra5000 to the cabinet, first using the upper mounting slots
of the drive and then the lower. The recommended mounting hardware is
M5 metric (1/4-20) or #10 MS bolts. Observe bonding techniques as
described in Bonding Your System.
3. Tighten all mounting fasteners.