The Quik-Spec Coordination Panelboard (QSCP) makes selective
coordination easy. Now available with up to 600 A mains and up
to 200 A branch disconnects as well as advanced and integrated
surge options.
Overview
Core features
Easy-to-Spec
• Eaton's Bid Manager makes specifying, pricing and ordering
simple, fast and virtually error free. Just log in, select the ratings,
features and options you want, and instantly get back pricing for
any Coordination Panelboard possible. Contact your Bussmann
series products representative for access.

Saves Time
• Enclosure ships within one week of order so installation can start
fast. Interior with fuses ships later for jobsite installation. Spare fuses
included with chassis shipment so replacements are always on hand.
• Specify Quik-Ship when you order and your product will ship within
10 business days. Available on all NEMA 1 enclosure configurations -
just make sure your Bussmann series product representative knows
you want Quik-Ship.
Flexible Configurations – Up to 600Vac/600 Amp/200kA SCCR,
or 125Vdc/600 Amp/100kA SCCR. 125Vdc rating applicable on
MLO panels only, up to 80A.
• 30. 60. 100. 200. 225. 400 and 600 A main ratings
• 125 Vdc rating ideal for utility and petro-chem control circuits or UPS
circuits
• 1 to 100 A fuse ratings to closely match loads
• Available in fused or non-fused main disconnect switch, or MLO (Main
Lug Only) configurations with a choice of 18. 30. 42. 60. 72 and 84 branch
positions, up to 200 A, in NEMA 1 or 3R enclosures to easily meet branch
or service panel installation needs
• Feed through lugs or fused loadside disconnect available
• Same size footprint as traditional circuit breaker panelboards
• 20” W x 5” D x various heights (depending on configuration), See data
sheet for specific dimensions/configurations
Addresses NEC® Selective Coordination Requirements
• This cULus Listed panelboard makes it easy to provide systems that
comply with NEC® Selective Coordination Requirements for Emergency,
Legally Required Standby, Healthcare Essential Electrical and Critical
Operation Power Systems (COPS) per 700.27. 701.18. 517.26 and 708.54
• Full fuse-system selective coordination is easy from source to branch.
Just follow published fuse selective coordination ratios – no need for
plotting time-current curves or expensive studies
Increases Safety
• The QSCP uses the Bussmann series Compact Circuit Protector Base
(CCPB) for its branch circuit disconnect up to 100 amps and the Compact
Circuit Protector (CCP) for its 200 amp branch circuit disconnect. Both are
used with Bussmann series Class CF CUBEFuse fuses
• Both CCP and CCPB are disconnect rated to provide a means for load
isolation. Ampacity rejections at 15. 20. 30. 40. 50. 60. 70. 90. 100 and
200 A coincide with standard conductor sizes to help prevent overfusing
• Local open fuse indication on branch circuit device and optional indicating
CUBEFuse
• Lockout/tagout provision eases OSHA compliance
• Lock-On provision helps meet requirements for emergency circuits
• High fuse interrupting rating and up to 200 kA assembly SCCR ratings
easily exceed most available fault current levels to help ensure compliance
with NEC® 110.9 and 110.10. Current-limitation of a fused solution also
reduces arc-flash hazards and minimizes damage to equipment and circuits.
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com