Measures Optical Wavelength with High Accuracy of 2 ppm
and High Resolution of 0.001 nm.
● Fast sampling: Five measurements/sec.
● Frequency and deviation displays
Wavelength Meter Using He-Ne Laser as Reference Wavelength
The Q8326 is an optical wavelength meter that
measures an emission center wavelength with high resolution.
The Q8326 uses a He-Ne laser for the reference
wavelength and uses the Michelson interference
method to enable high accuracy measurement.
This wavelength meter achieves
fast sampling (five per second) which is optimum
for oscillation wavelength adjustment of
LD for DWDM. With the deviation display
function, wavelength fluctuations can also be
measured with high resolution and accuracy.
Applications
•Optimum for LD wavelength adjustment for DWDM due to
fast sampling measurement.
•Can be used as a wavelength standard for spectroscope calibration
due to high accuracy.
•Can be automated to measure the LD wavelength temperature
characteristics and wavelength current characteristics.
High Resolution
The Michelson interference method allows high resolution
measurements of up to 0.001 nm/100 MHz.
High Accuracy Measurements
Use of a He-Ne laser for the reference wavelength enables high
accuracy measurements of up to 2 ppm. In addition, since the
He-Ne laser oscillates with high stability, a 2 ppm measurement
accuracy is guaranteed over a long time period without recalibration.
Wide Bandwidth
The measurement range covers short wavelengths of 480 to
1000 nm and long wavelengths of 1000 to 1650 nm and is
selectable via a single switch operation.
High-speed Sampling
The Q8326 can measure wavelengths at a sampling speed of
five per second so that wavelength fluctuations caused by temperature
variations can be captured precisely.
Frequency and Deviation Displays
The Q8326 can not only display the wavelength but can also
be switched to display the frequency of the beam under measurement,
which is convenient for adjusting the oscillation
wavelength to the ITU-T grid. Since the deviation is displayed
using the keyed entry as the reference, wavelength fluctuations
of the LD caused by temperature variations can be viewed with
high resolution and high precision.
GPIB Provided as Standard
Standard provision of GPIB allows the Q8326 to be used as a
component for an automated measuring system utilizing fast sampling.