Description
The NGC8206 analyzes each sample utilizing established
chromatographic techniques. The resulting information
consists of mole percent values for the following:
• “Air” (Contains N2, Ar, CO and O2 but not CO2)
• C1 CO2 C2 C3 IC4 NC4
• NeoC5 IC5 NC5 C6+
Using process chromatographic techniques, the columns are
back flushed so that the NGC8206 measures a C6+ peak. Users
may input the results of a comprehensive lab analysis that
reflects the split or ratio of C6 through C10 components. This
ratio can be used in subsequent analysis and energy
calculations. Calculated values include:
• Gas compressibility per AGA 8
• Real Relative Density (Specific Gravity)
• Btu/CV Value
• GPM (gallons of liquid per thousand cubic feet)
• Wobbe Index
• Methane Number
• Optional calculations can include: AGA 10 speed of sound,
Hydrocarbon Dew Point
Installation
The NGC8206 is a weatherproof device designed for
installation “on the pipe” near to the sampling point. This
means it is acceptable to mount outside - in a temperature
range of 0°F to 130°F (–18°C to 55°C) [provides reliable
operation for –20°F to 130°F (–29°C to 55°C) with low
temperature option] onto a pipeline with 2" to 12" pipe sizes or
with an optional pole mount configuration. A cold weather
enclosure is also available if ambient conditions are below
either the sampled gas dew point or the operational
specifications of the unit