Description
The NGC8206 analyzes each sample utilizing established
chromatographic techniques. The resulting information
consists of mole percent values for the following:
• “Air” (Contains N2, Ar, CO and O2 but not CO2)
• C1 CO2 C2 C3 IC4 NC4
• NeoC5 IC5 NC5 C6+
Using process chromatographic techniques, the columns are
back flushed so that the NGC8206 measures a C6+ peak. Users
may input the results of a comprehensive lab analysis that
reflects the split or ratio of C6 through C10 components. This
ratio can be used in subsequent analysis and energy
calculations. Calculated values include:
• Gas compressibility per AGA 8
• Real Relative Density (Specific Gravity)
• Btu/CV Value
• GPM (gallons of liquid per thousand cubic feet)
• Wobbe Index
• Methane Number
• Optional calculations can include: AGA 10 speed of sound,
Hydrocarbon Dew Point
Installation
The NGC8206 is a weatherproof device designed for
installation “on the pipe” near to the sampling point. This
means it is acceptable to mount outside - in a temperature
range of 0°F to 130°F (–18°C to 55°C) [provides reliable
operation for –20°F to 130°F (–29°C to 55°C) with low
temperature option] onto a pipeline with 2" to 12" pipe sizes or
with an optional pole mount configuration. A cold weather
enclosure is also available if ambient conditions are below
either the sampled gas dew point or the operational
specifications of the unit.
Sample conditioning system
The integral stream selector for the NGC8206 allows sampling
up to four (4) different natural gas streams. Up to two of these
sample streams can be designated as the “calibration/
validation sample”. Optional sample conditioning modules are
available to address natural gas streams that need additional
filtering and “speed loops” to reduce sample transport lag times.
Operator interface
Functional setup and operation of the NGC8206
is accomplished by using a graphical user’s interface software
package called PCCU 32 (supplied with each unit) operating on
a laptop PC in a Microsoft® Windows® environment. The
“Windows®” utilities, combined with software designed
specifically for the NGC8206, provide a powerful tool for
operations, diagnostics, and downstream data handling.
The PC can be directly connected to the NGC8206 via an
RS-232, USB, or Ethernet connection, or indirectly by remote
telemetry (phone modem, radio, cell phone, satellite, etc.).
The user is prompted through push-buttons, drop-down
boxes, wizards, and dialog boxes for setup, operations, data
collection and monitoring.
In addition, the unit has an optional ¼ VGA interactive display
screen allowing the user access to basic analysis data. The
user can also accomplish most of the “operator” functions
from the front panel display with out the use of a laptop PC.
The “Run-Hold-Calibrate” functions can be done via a magnet
interface through the explosion proof glass in the display