Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

GE IC697PCM711 Programmable Coprocessor Module

From:GE | author:Mr.Chen | Time :2025-03-26 | 267 view: | 🔊 Click to read aloud ❚❚ | Share:

Features

• Single slot Coprocessor

• Dual Tasking

• MegaBasic

• CCM2 Protocol

• 12 Mhz, 80C186 microprocessor

• 90% of an IBM AT performance

• Up to 96 Kbytes battery-backed CMOS logic and

data memory on board

• Supports up to 512 Kbytes optional expansion memory

• Programmed by IC647. IC640 or IBM-compatible

Personal Computer

• Two RS-422/RS-485 or RS-232 serial ports

• High performance access to PLC memory

• Real time calendar clock synchronized to PLC

• Reset pushbutton

• Three Status LEDs

• Soft Configuration (No dip switches or jumpers)

with MS-DOS or Windows based programming

software configuration function

• Simultaneous communications on both ports at up

to 9.6 Kbaud, or up to 19.2 Kbaud individually.

Functions

The Programmable Coprocessor Module (PCM) is a

Coprocessor to the PLC CPU.  It can be programmed

to perform operator interface, real time computations,

data storage, data acquisition and data communica

tions functions.  It communicates with the PLC CPU

over the backplane and can access user and system

data using extensions to the powerful MegaBasic lan

guage.  No application program support is required in

the PLC CPU.

Many PCMs can be supported in a single IC697 PLC

system and each can accommodate an optional ex

pansion memory up to 512 Kbytes.

Dual tasking allows running a MegaBasic program at

the same time the PCM is used as a communications

interface.  Operation of the module may be initialized

by a pushbutton or by an attached PCM development

system.  The status of the PCM is indicated by three

green LEDs on the front of the module.

Installation

• Installation should not be attempted without refer

ring to the applicable Programmable Controller

Installation Manual (see reference 5).

• Make sure rack power is off.

• Install expansion memory if required.

• Connect the battery to either of the battery con

nectors on the module. (See figure 2)

• Install in the rack. (See figure 1)

• Turn on power.

The module should power up and blink the top LED.

When the diagnostics have completed successfully the

top LED stays on.

Expansion Memory

The PCM can operate with or without an expansion

memory daughter board.  The base memory on the

PCM board has up to 95 Kbytes user memory.  The ex

pansion memory daughter board permits expansion of

program/data memory by 64. 128. 256 or 512 Kbytes.

The battery which supports this memory is located on

the base board housing as shown in figure 2.

  • KEBA AR 281 ANALOGE INPUT BOARD
  • Engel Keba EC100 PLC Rack with PS244 CU211 PD242 AR181 TT081 DO321 DI325 (19821)
  • KEBA CU 313 Central Unit CU 313/C-SI/63036 Card 128MB
  • KEBA TM-240/A PLC MODULE
  • Keba D1633C E-Cpu-186B Cpu Control Circuit Board W/ D1630D
  • Keba Engel E-CON-CC100/A/22178 HMI Operator Control Display Panel
  • KEBA K2-200 CP 242/B controller module
  • KEBA KEVIEW V2 341/C-4400 HMI TOUCHSCREEN UNIT 84494 24 VDC
  • KEBA E-8-THERMO 1770B-1 Thermocouple circuit board
  • KEBA 3HAC12929-1 TEACH PENDANT
  • Keba KETOP C50 R/73810/06 KEBA PANEL OPERATOR DISPLAY
  • KEBA Kemro K2-400 DO 470/B 059707 Module
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Beckhoff EL2502-0010 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2502 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 0.5 A
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protectio
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • SAACKE FSC-01V3.02/V3.00 Industrial Combustion Controller
  • GE Multilin 750-P5-G5-S5-HI-A20-G 750 Management Relay
  • GE Multilin 750-P5-G5-D5-HI-A20-R 750/760 Feeder Mgmt Relay Series
  • GE Multilin 750-P5-G5-D5-HI-A20-G Management Relay
  • GE Multilin 750-P5-G1-D5-HI-A20-R Multilin 1A Zero Sequence Current Inputs
  • GE Multilin 750-P1-G1-S1-HI-A20-R-T-H Feeder Management Relays
  • GE Multilin 750-P1-G1-S1-HI-A20-R Feeder Management Relays
  • GE Multilin 750-P1-G1-D1-HI-A20-R Base Unit 750 Relay
  • GE Multilin 239-RTD-AN-H motor protection relay
  • GE Multilin 489-P5-HI-A20-T-H Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-T Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-E-H Relay Motor Management
  • GE Multilin 489-P1-LO-A20 489 Motor Management Relay Base Unit
  • GE Multilin SR469-P5-LO-A20-T Motor Management Relay
  • GE Relay from GE Grid Solutions SR469-P5-LO-A20-E
  • GE Multilin SR469-P5-LO-A20 Motor Management Relay with Case
  • GE Multilin SR469-P5-HI-A20-T 469 Series Relay
  • GE Multilin SR469-P1-HI-A1-E-H 469 Series Relay
  • GE Multilin SR469-P1-H1-A1-E 469 Series Relay
  • GE Multilin 469-P5-LO-A20-T Phase Current Input 5 A Phase CT Secondaries
  • GE Multilin 469-P5-LO-A20-E LO Control Power with 4-20mA Analog Outputs
  • GE Multilin 469-P5-LO-A20 Motor Management Relay
  • GE Multilin 469-P5-HI-A20-E-H Motor Management Relay
  • GE Multilin 469-P5-HI-A20 469 Motor Management Relay
  • GE Multilin 469-P1-HI-A1-E-H 469 Base Unit Motor Management Relay
  • GE Multilin 469-P1-H1-A1-E 469 Motor Mgmt Relay
  • Beckhoff ED2504 | EtherCAT Terminal, 4-channel PWM output
  • Beckhoff EL2262 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2258 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff EL2252 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A, timestamp
  • Beckhoff EL2212 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2202-0100 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2202 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A, push-pull, tristate
  • Beckhoff EL2124 | EtherCAT Terminal, 4-channel digital output, 5 V DC, 20 mA
  • Beckhoff EL2088 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, ground switching
  • Beckhoff EL2084 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, ground switching
  • Beckhoff EL2068 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, with channel diagnostics
  • Beckhoff EL2044 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with extended diagnostics
  • Beckhoff EL2042 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 x 4 A/1 x 8 A
  • Beckhoff ED2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, push-in, with channel diagnostics
  • Beckhoff EL2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with diagnostics
  • Beckhoff ED2032 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, push-in, with channel diagnostics
  • Beckhoff EL2032 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, with diagnostics
  • Beckhoff EL2024-0010 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2024 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2022 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2014 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, with extended diagnostics
  • Beckhoff ELX2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 30 mA, Ex i
  • Beckhoff ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in
  • Beckhoff EL2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A
  • Beckhoff EL2004 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A
  • Beckhoff ELX2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 45 mA, Ex i
  • Beckhoff EL2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A
  • TMEIC TM21-TG Series 2-Pole Generator
  • TMEIC TM21-TG Series 4-Pole Generator for Turbine Drive
  • TMEIC Air-Cooled Type Synchronous Generators
  • TMEIC TMdrive-XL85 Medium Voltage AC Drives
  • TMEIC TMdrive-30 Medium Voltage AC Drives
  • TMEIC TMdrive-MVG2 Medium Voltage AC Drives
  • TMEIC TMdrive-70 Medium Voltage AC Drives
  • TMEIC TMdrive-50 Medium Voltage AC Drives
  • TMEIC TMdrive-MVe2 Medium Voltage AC Drives
  • TMEIC TMdrive-XL80 Medium Voltage AC Drives
  • TMEIC TMdrive-XL75 Medium Voltage AC Drives
  • TMEIC TMdrive-XL55 Medium Voltage AC Drives
  • TMEIC TMdrive-70e2 Medium Voltage AC Drives
  • TMEIC TMdrive-Guardian Medium Voltage AC Drives
  • TMEIC TMdrive®-10e2 DP DC Drives
  • TMEIC TMdrive-DCe2 DC Drives
  • TMEIC Dynamic VAR Compensation – Dyna-VAR™
  • TMEIC PV Inverters SOLAR WARE 2500
  • TMEIC PV Inverters SOLAR WARE 2700
  • TMEIC PV Inverters SOLAR WARE 3200
  • TMEIC Power Plant Controller
  • TMEIC High-voltage motors 21-L series
  • TMEIC MV Motor & Drive Solutions for Power Generation
  • TMEIC AC Motors Rolling Mills
  • TMEIC TMdrive®-70 Medium Voltage 3-Level IEGT System Drive
  • TMEIC TMdrive®-70e2 Medium Voltage 3-Level IEGT System Drive
  • TMEIC TMdrive-MVe2 Reactive Power Control
  • TMEIC TMdrive®-30 Medium Voltage 3-Level IGBT System Drive
  • TMEIC Unified Controller nv Series
  • DEIF MVR-F215 Product description
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF PPM 300 Protection & power management
  • DEIF RMC-142D Current relay
  • DEIF GPU-3 hydro Generator protection unit
  • DEIF MVR-200 series Medium Voltage Relay