From:Hitachi | author:Mr.Chen | Time :2024-07-23 | 658 view: | Share:

- Integrated Managed Layer 2 Switch

- 24... 60 VDC supply voltage

- 4x 10/100 BaseT (RJ45. auto-negotiation)

- 2x SHDSL ports (for copper)

- Redundant topology via Spanning Tree Protocol (STP/ RSTP/ MSTP)

- 1x RS-232/ RS-485 and 1x RS-232 interfaces for tunneling of serial protocols

Applications

The DIN-rail mountable 500NMD02 is a managed plug-and-play Layer 2 switch offering

- 4 Fast Ethernet auto-negotiating RJ45 ports with automatic MDI/X (automatic cross detection and correction)

- Two 2-wire SHDSL ports for dedicated copper cabling

- 1 RS-232/ RS-485 interface and 1 RS-232 interface for serial protocol tunneling

The switch provides redundant topology via Spanning Tree Protocol (STP/ RSTP/ MSTP). It supports VLAN framing and serial data tunnelling.

Ethernet can be distributed within the station via the switch's four RJ45 ports.

The SHDSL port can be used for interstation interconnections up to a maximum distance of 25 km (0.8 mm diameter copper cable).

The SHDSL interface connects to any EDS500 SHDSL-compatible device, including the 560NMS24 and 560NMS34. as well as any EFM-based SHDSL device.

Features

For documentation purposes, the Ethernet ports are labelled 1 to 4 and there are no specific uplink ports.

All ports are functionally identical, and the SHDSL port is connected via a pluggable threaded connector.

The link and speed status of each Ethernet port and SHDSL port is indicated by status indicators (see ‘Connectors and Indicators’).

The switch learns the Ethernet address by analysing incoming frames and stores it in a lookup table (up to 2048 entries).

used to forward frames only to the correct port. If it is a broadcast or multicast, or if the destination address is not found in the lookup table, the

then the received frame is forwarded to all ports other than the receiving port. If an incoming frame with a specific source address does not refresh the entry in the lookup table, the

entry with a specific source address is not refreshed, the entry will age out in a maximum of 304 seconds (by default, this value is configurable).

For IEEE 802.1Q VLAN frames, the switch can be configured in VLAN or transparent mode.

In transparent mode, the switch does not change any frames or frame TAGs; in VLAN mode, the switch can be configured to support multiple applications.

In VLAN mode, the switch can be configured to support multiple applications, such as trunking or access ports.

The switch can support quality of service if it uses IEEE 802.1p-compliant frame formats.

The switch can divide frames into up to four queues, which can be configured as priority-based or weighted fair queues.

The 500NMD02 uses a wide-range power supply and operates from 24 to 60 V. The 500NMD02 can be configured to operate on a wide-range power supply.

The components themselves, the Ethernet ports, the SHDSL connections, the RS-232 interface, and the Extended Bus Interface (Ext) are all hot-swappable.

Topology

The 500NMD02 offers a total of six ports for use with end devices, switches, bridges, hubs and routers.

The switches can be easily built into star, ring, or line topologies.

Management and Configuration

Management and configuration of the 500NMD02 can be performed via Telnet, Secure Shell (SSH), SNMP, RS-232. or a network interface.

All methods can be used to read or write device parameters.

In addition, the interface and alarm status of the device can be monitored via IEC 60870-5-101 or -104.

Existing configurations can be saved and restored. The configuration can also be stored in an external configuration stick (500NMA01).

This makes it simple to swap devices without trained personnel.

By default, the 500NMD02 switch is configured with an IP address of 10.0.0.2. a subnet mask of 255.0.0.0. and a gateway of 10.0.0.1.

Connections for configuration purposes can be accepted through any interface. All Ethernet ports are in the default state.

The RS-232 interface is preconfigured with baud rate 57600. 8 data bits, no parity, 1 stop bit (57600.8N1), 8N1).

The command line interpreter configured via this interface can be accessed by any terminal software (e.g. HyperTerminal).

Rapid Spanning Tree Protocol (RSTP) or Multiple Spanning Tree Protocol (MSTP) automatically detects and handles redundant topologies.

  • Alstom 029.232 446 Central Unit VME A32/D32 | COP 232.2
  • ABB REF610B11LCNP Feeder Protection and Control
  • A-B 1794-IN106 Input/Output Analog Modules
  • General Electric 029.381208 Converteam Controller Module
  • Eaton XIOC-BP-3 Moeller 3-Signal Module Backplane
  • ETON XVS-460-57MPI-1-1E Industrial-grade Embedded Touch Screen
  • EATON XVS-430-57MPI-1-10 Touch Panel
  • EATON XV-430-12TSB-1-10 Touch Panel
  • EATON XV-440-12TSB-1-10 Touch Panel
  • Eaton MP-3010 66D2205G01 Motor Protection Relay
  • Eaton CS-TX3-3.81X2.54-64TW Terminal Block
  • XIOC-BP-XC1 | Eaton XC modular programmable logic controller
  • EATON XVS-430-10MPI-1-10 Touch Panel
  • Eaton 8922-RB-IS Isolated Signal Isolator
  • Eaton XV-442-57CQB-1-10 Touch Panel
  • Eaton DPM-MC2 Communication Module
  • Eaton MPB2-TP Communication module
  • DEIF DM-4 hydro Delomatic 4 hydro
  • DEIF DU-2/MKIII | DEIF Multi-instrument
  • DEIF PCM4.3 DEIF PCM4.3 Power Control Module
  • DEIF DM-4 marine Integrated systems
  • DEIF TAS-331DG AC transducer for active or reactive power
  • DEIF TAC-311DG Single-function transducer
  • DEIF IOM4.2 DEIF IOM4.2 Input/Output Module
  • DEIF PSM-1 Power System Management Module
  • DEIF D45, E45 & B45 Meters for DIN rail mounting
  • DEIF DPS-1 DC Power Supply
  • DEIF CIO 208 CAN bus-based I/O module
  • DEIF DPR Edgewise moving coil
  • DEIF DM 400 gas Integrated systems
  • DEIF DCP2 (24V) DC power supply
  • DEIF DIM-Q Insulation monitor
  • DEIF CIO 308 CAN bus-based I/O module
  • DEIF OPM-1 DELOMATIC-MULTI-FUNCTION SYSTEM
  • DEIF SCM4.1 DEIF SCM4.1 Control Module
  • DEIF DELOMATIC-3 DGU2 Control Module
  • DEIF LSU-112DG Load sharing, paralleling & operation
  • DEIF DLQA series Illuminated 360° azimuth indicators
  • DEIF DLQ series Illuminated marine bridge instrument
  • DEIF DCF-Q96 DC integrator, pulse transmitter
  • DEIF CSQ-2 Check synchronising relay
  • DEIF LSU-113DG Load sharing, paralleling & operation
  • Deif IPM-1 Delomatic Input Module
  • DEIF PCM4.4 Differential Current Relay
  • DEIF CM-2 Deif Cm-2 Control Module
  • DEIF DM-4 gas Delomatic 4 gas
  • DEIF DM-3 Multi-function system
  • DEIF DLQW series Watertight marine instruments with Illumination
  • DEIF CSQ-3 Multi-function synchroscope
  • DEIF CIO 116 CAN bus-based I/O module
  • DEIF PPU 3 paralleling & protection unit (PPU)
  • DEIF RMV-112D Voltage Relay
  • DEIF GPU 2 GS Multi-line 2/version
  • DEIF SCM-1 Smart Communication Module
  • Studer Communicator A8600 Controller
  • Bently 3500/42M 140734-99 Proximitor Seismic Monitor
  • Bently 3701/55 289761-01 ADAPT (ESD) Emergency Shutdown Device
  • Bently 3701/55 323174-01 ADAPT (ESD) Emergency Shutdown Device
  • Bently 3500/15 114M5330-01 AC and DCPower Supplies
  • Bently 3500/42M 140734-02 Proximitor Seismic Monitor
  • Bently 1900/65A 172323-01 Vibration Monitoring Controller
  • Bently 1900/65-00-01-03-01-01 General Purpose Equipment Monitor
  • Bently 3500/93 135785-02C Backlit Display Unit
  • Bently 1900/65A-01-01-03-00-01 General Purpose Equipment Monitor
  • Bently 3500/54-03-00 Dual channel overspeed detection module
  • Bently 1900/65A-00-01-01-01-01 General Purpose Equipment Monitor
  • Bently 3300/16-11-01-03-00-00-01 XY/Gap Dual Vibration Monitor
  • Bently 3300/20-12-01-03-00-00 Proximitor Monitor
  • Bently 330103-00-03-05-02-05 Proximity Transducer System
  • Bently 330703-000-070-10-02-05 3300 XL 11 mm Proximity Transducer System
  • Bently 330104-00-05-10-02-CN 8 mm Proximity Probes
  • Bently 22810-01-05-50-02 Velomitor Piezoelectric Speed Sensor
  • Bently 330876-03-50-00-00 Proximity Probe / Armored High-Temperature FluidLoc Cable
  • Bently 330130-085-00-00 3300 XL 8 mm Proximity Transducer System
  • Bently 330901-05-32-05-02-00 Proximity Transducer System
  • Bently 330108-91-05 Vibration Monitoring Sensor
  • Bently 84152-01 Shielded Sensor Cable Assembly
  • Bently 330104-00-05-10-02-00 Proximity Transducer System
  • Bently 163179-02 2024 temperature module
  • Bently 330180-X1-CN 3300 XL 8 mm Proximity Transducer System
  • Bently 128277-01 Vibration Monitoring Module
  • Bently 1-536067-4 TE Connectivity AMP Connectors
  • Bently 1X35668 Vibration extension cable
  • Bently 330130-045-00-00 Standard Extension Cable
  • Bently 330980-51-00 3300 XL NSv Proximitor Sensor
  • Bently 9200-01-01-10-00 Seismoprobe Velocity Transducers
  • Bently 149986-01E 16-Channel Relay Module
  • Bently 3500/45 176449-04 Position Monitor
  • Bently 3500/53 133388-01 Overspeed Detection Module
  • Vibro-meter VM600-ABE042 204-042-100-011 Precision Control Module
  • Vibro-meter vmf-MPC4 200-510-111-034 200-510-070-113 Module
  • Vibro-Meter VM600 204-040-100-012 measurement module
  • VIBRO-METER VM600-CSA 204-040-100-211 PLC module
  • Vibro-meter 200-560-000-018 200-560-101-015 VM600 IOC4T Module
  • Vibro-meter VM600-ABE040 204-040-100-011 system racks
  • Vibro-meter VM600 RPS6U rack power supply
  • Vibro-meter VM600-RPS6U 200-582-200-011 cutting-edge monitoring module
  • Vibro-meter VM600 RLC16 relay card
  • Vibro-meter VM600 CMC16 Condition Monitoring Card
  • Vibro-meter 200-582-915-032 VM600 power supplies Module
  • Watlow PPC-TB50 Process/Temperature Controller
  • Watlow PPC-TB50 30280-00 terminal board
  • Watlow F4T | Integrated Process Controller
  • Watlow SERIES F4 Ramping Controller
  • Watlow CLS208 C10000CP Multi-zone Temperature Controller
  • Watlow CLS216‌ CLS200 series temperature controller
  • Watlow PPC-TB50 30280-00 CLS208 208-1200000 terminal board
  • WATLOW CAS 16CLS/CAS temperature controller
  • WATLOW CAS200 CLS216 Temperature Controller
  • 1SVR011732R1300 ABB - Converter: temperature
  • 1SVR011712R1700 ABB Control - Datasheet PDF & Technical Specs
  • ALSTOM NRD108033 8RDC44667G01 SA44667.C Interface Module
  • ALSTOM VOOB8-B 12004-106-04 VER:V1.0.0 8-channel digital output module
  • ALSTOM MFAC34N1AA0001A Auxiliary Speed Relay
  • ALSTOM I/OBE2 12004-104-00 V1.0.0 Safety I/O Module
  • ALSTOM POS1846 TRVC062333000 CP00000310 Vehicle control module
  • ALSTOM 42011-106-00 A01 ITC_VIOM_VIOC VER.A01 Industrial Control Module
  • ALSTOM NRD108028 8RDB43655 SA43655.E Interface Module
  • ALSTOM I/OBUS2 12004-103-01 VER:V1.2.0 Bus Interface Module
  • ALSTOM MCHN02D1AB0005A Controller
  • ALSTOM VIIB16-C 12011-105-00 V1.0.0 Digital Interface Module
  • ALSTOM N897092520B N897092057Y TRENO N897092500E Control System Module
  • ALSTOM CMP1838 TRVCO62345000 process control module
  • ALSTOM PIB101C Industrial-Grade PCB Module
  • ALSTHOM MCGG22D1CB0753C Controller
  • ALSTOM STO1726KO1 Safety Torque Off (STO) module
  • ALSTOM CMU 42015-115-00 Amplifier controller
  • ALSTOM 730475-D ELEMENTS-F2 Control Pulse Card