Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

Hitachi Energy 500NMD02 Managed Plug and Play Layer 2 Switch

From:Hitachi | author:Mr.Chen | Time :2024-07-23 | 1315 view: | 🔊 Click to read aloud ❚❚ | Share:

- Integrated Managed Layer 2 Switch

- 24... 60 VDC supply voltage

- 4x 10/100 BaseT (RJ45. auto-negotiation)

- 2x SHDSL ports (for copper)

- Redundant topology via Spanning Tree Protocol (STP/ RSTP/ MSTP)

- 1x RS-232/ RS-485 and 1x RS-232 interfaces for tunneling of serial protocols

Applications

The DIN-rail mountable 500NMD02 is a managed plug-and-play Layer 2 switch offering

- 4 Fast Ethernet auto-negotiating RJ45 ports with automatic MDI/X (automatic cross detection and correction)

- Two 2-wire SHDSL ports for dedicated copper cabling

- 1 RS-232/ RS-485 interface and 1 RS-232 interface for serial protocol tunneling

The switch provides redundant topology via Spanning Tree Protocol (STP/ RSTP/ MSTP). It supports VLAN framing and serial data tunnelling.

Ethernet can be distributed within the station via the switch's four RJ45 ports.

The SHDSL port can be used for interstation interconnections up to a maximum distance of 25 km (0.8 mm diameter copper cable).

The SHDSL interface connects to any EDS500 SHDSL-compatible device, including the 560NMS24 and 560NMS34. as well as any EFM-based SHDSL device.

Features

For documentation purposes, the Ethernet ports are labelled 1 to 4 and there are no specific uplink ports.

All ports are functionally identical, and the SHDSL port is connected via a pluggable threaded connector.

The link and speed status of each Ethernet port and SHDSL port is indicated by status indicators (see ‘Connectors and Indicators’).

The switch learns the Ethernet address by analysing incoming frames and stores it in a lookup table (up to 2048 entries).

used to forward frames only to the correct port. If it is a broadcast or multicast, or if the destination address is not found in the lookup table, the

then the received frame is forwarded to all ports other than the receiving port. If an incoming frame with a specific source address does not refresh the entry in the lookup table, the

entry with a specific source address is not refreshed, the entry will age out in a maximum of 304 seconds (by default, this value is configurable).

For IEEE 802.1Q VLAN frames, the switch can be configured in VLAN or transparent mode.

In transparent mode, the switch does not change any frames or frame TAGs; in VLAN mode, the switch can be configured to support multiple applications.

In VLAN mode, the switch can be configured to support multiple applications, such as trunking or access ports.

The switch can support quality of service if it uses IEEE 802.1p-compliant frame formats.

The switch can divide frames into up to four queues, which can be configured as priority-based or weighted fair queues.

The 500NMD02 uses a wide-range power supply and operates from 24 to 60 V. The 500NMD02 can be configured to operate on a wide-range power supply.

The components themselves, the Ethernet ports, the SHDSL connections, the RS-232 interface, and the Extended Bus Interface (Ext) are all hot-swappable.

Topology

The 500NMD02 offers a total of six ports for use with end devices, switches, bridges, hubs and routers.

The switches can be easily built into star, ring, or line topologies.

Management and Configuration

Management and configuration of the 500NMD02 can be performed via Telnet, Secure Shell (SSH), SNMP, RS-232. or a network interface.

All methods can be used to read or write device parameters.

In addition, the interface and alarm status of the device can be monitored via IEC 60870-5-101 or -104.

Existing configurations can be saved and restored. The configuration can also be stored in an external configuration stick (500NMA01).

This makes it simple to swap devices without trained personnel.

By default, the 500NMD02 switch is configured with an IP address of 10.0.0.2. a subnet mask of 255.0.0.0. and a gateway of 10.0.0.1.

Connections for configuration purposes can be accepted through any interface. All Ethernet ports are in the default state.

The RS-232 interface is preconfigured with baud rate 57600. 8 data bits, no parity, 1 stop bit (57600.8N1), 8N1).

The command line interpreter configured via this interface can be accessed by any terminal software (e.g. HyperTerminal).

Rapid Spanning Tree Protocol (RSTP) or Multiple Spanning Tree Protocol (MSTP) automatically detects and handles redundant topologies.

This is fully backward compatible with the widely used Spanning Tree Protocol (STP).

  • Basler Electric BE1-67 / BE167 DIRECTIONAL OVERCURRENT RELAY
  • Basler Electric BE1-25/79TR Reclosing Relay BE1 25 79TR
  • Basler Electric Contact Expansion Module CEM-2020
  • Basler Electric MVC-300 MANUAL VOLTAGE CONTROL UNIT 9121000106
  • Basler Electric KR2FF Voltage Regulator 9 1163 00 109
  • Basler Electric BE1-81O/UT3EE1YA9S0F / BE181OUT3EE1YA9S0F
  • Basler Electric BE1-87G-G1E-A1K-A0N0F / BE187GG1EA1KA0N0F
  • Basler Electric BE1-47NE3EA1PA0N2F / BE147NE3EA1PA0N2F
  • Basler Electric BE1-81-T1E-E1C-B0N1F / BE181T1EE1CB0N1F
  • Basler Electric BE1-25 SYNC-CHECK RELAY M1E A7P A5N3F
  • Basler Electric BE1-40Q Solid State Protective Relay/ Loss Of Excitation Relay
  • Basler Electric OVERCURRENT RELAY, BE1-50/51M-104
  • Basler Electric MVC 232 MANUAL VOLTAGE CONTROL 9037000103
  • Basler Electric SSE-N 250-9 KW Shunt Static Exciter-Regulator
  • Basler Electric, Solid State Protective Relay, BE1-60
  • Basler Electric SR4A-2B15B3A Static Voltage Regulator 120vac Includes U6250MKG1L
  • Basler Electric BE1-50BF Breaker Failure Relay
  • Basler Electric BE1A1HF1JD1S2F / BE1A1HF1JD1S2F
  • Basler Electric BE1-81O/UT3EE1JA7N2F / BE181OUT3EE1JA7N2F
  • Basler Electric EXCITER DIODE MONITOR EDM-200
  • Basler Electric DECS125-15-B2C5 DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric OVER CURRENT RELAY 9252000107
  • Eaton Sag Ride-Through power conditioner
  • Eaton Sag Ride-Through power conditioner
  • Eaton Power-Sure 800
  • Eaton Power-Sure 700
  • Eaton Power-Suppress 600
  • Eaton T100H-2500-5HC PWR SUPPRESS T100 HW 2.5KVA, 50 HZ, 55DEG C MAX
  • Eaton T100H-1800 PWR SUPPRESS T100 HW 1.8KVA
  • Eaton 9468-ET IS Ethernet Isolator
  • Eaton 9466-ETA IS Ethernet Managed Switch
  • Eaton 9466-ET IS Ethernet Managed Switch
  • Eaton 9465-ETA-S-SC IS Media Converter Single-mode
  • Eaton 9465-ET-M-ST IS Media Converter Multimode
  • Eaton 9465-ET-S-SC IS Media Converter Single-mode
  • Eaton 9465-ET-M-SC IS Media Converter Multimode
  • Eaton 9461-ET IS Serial to Ethernet Gateway
  • Beckwith Electric M-0067E Tapchanger Control
  • Beckwith Electric M-2001D Digital Tapchanger Control
  • Beckwith Electric M-2001C Digital Tapchanger Control
  • Beckwith Electric B-1500 Battery Backup Power
  • Beckwith Electric B-2083 SmartBank Three Phase Junction Box
  • Beckwith Electric M-2017 Capacitor Bank Discharge Tool
  • Beckwith Electric M-2980A Weatherproof Capacitor Control Cabinet
  • Beckwith Electric M-6283A Three Phase Digital Capacitor Bank Control
  • Beckwith Electric M-6280A Digital Capacitor Bank Control
  • Beckwith Electric M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-3420 Generator Protection Relay
  • Beckwith Electric M‑0193B Syncrocloser® Unit
  • Beckwith Electric M-3520 Intertie Protection Relay
  • Basler Electric BE1-25 Sync-check Protective Relay
  • Basler Electric RDP-110 REMOTE DISPLAY PANEL
  • Basler Electric SSR 125-12 VOLTAGE REGULATOR 9185900102 WITH MODULE 9261500101
  • Basler Electric BE1-851 OVERCURRENT PROTECTION RELAY MECHANISM G3A1S1N
  • Basler Electric 149D930G02 / 149D930G02
  • Basler Electric BE1-81O/UT3EE1LB7S1F / BE181OUT3EE1LB7S1F Digital Frequency Relay
  • Basler Electric BE1-51/27CA1EZ10A0N0F / BE15127CA1EZ10A0N0F Time Overcurrent Relay
  • Basler Electric 149D956G02 / 149D956G02
  • Basler Electric BE1-51A / BE151A Overcurrent Relay
  • Basler Electric BE1-40Q-F3E-E10-A0N0F / BE140QF3EE10A0N0F
  • Basler Electric RDP-110-S1 Generator Annuciator
  • Basler Electric DECS-300 DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric - DECS-200-1C - Digital Excitation Control System
  • Basler Electric DECS125-15 Digital Excitation Control System with Power Module
  • Basler Electric BE1-87G Variable Percentage Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric / Kohler BE1-11g Generator Protection Relay G5A3M2J2N0E000
  • Basler Electric BE1-81O/UT3ED1JA7N2F / BE181OUT3ED1JA7N2F
  • Basler Electric BE1-81O/UT3EE1YB7N1F / BE181OUT3EE1YB7N1F
  • Basler Electric DECS-200 -1L DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric DECS 125-15-B2C1 V.2.0.9 DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric 9507900205 SSR Retrofit Static Voltage Regulator
  • Basler Electric BE2000E Digital Volatge Regulator
  • BASLER DECS-250-CN1CN1N DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric DGC-2020 Digital Genset Generator Controller Panel Enclosure
  • Basler Electric BE1-81O/UT3ED1LA7N0F / BE181OUT3ED1LA7N0F
  • Basler Electric BE1-81O/UT3EE1YA9S0F / BE181OUT3EE1YA9S0F
  • Basler Electric BE1-81O/UT3EE1YA6N1F / BE181OUT3EE1YA6N1F
  • Basler Electric DECS125-15 DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric BE1-951 OverCurrent Protect System
  • Basler Electric BE1-700V Digital Protective Relay N3N2X1N
  • APR63-5 Basler Electric Automatic Voltage Regulator
  • Basler BE1-851 overcurrent relay
  • Basler Electric BE1-87T Transformer Differential Relay Module
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler Electric 9310300100 DECS-300 Digital Excitation Control System
  • Basler Electric SSE-N 125-4.5KW SHUNT EXCITER REGULATOR
  • Basler Electric DGC-2020HD-5NS1DNSBA Digital Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F / BE181OUT3EE1JB7N1F
  • Basler Electric BE1-81T1EE1WA0N1F / BE181T1EE1WA0N1F
  • Basler Electric BE1-25M1EA6PN5R1F / BE125M1EA6PN5R1F
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric DECS-250 - CN2CN 1N Digital Excitation Control System Unit
  • Basler Electric Relay BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 DIGITAL EXCITATION CONTROL SYSTEM
  • DECS-200-1C Digital Excitation Control System
  • Basler Electric DECS-200N-C1 Negative Forcing Digital Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250 DIGITAL EXCITATION CONTROL SYSTEM DECS-250-LN1CN1N
  • Basler Electric DECS-250 LN2SA1D Digital Excitation Control System Unit
  • Basler Electric BE1-87T-A1E-A1J-D0S1F / BE187TA1EA1JD0S1F
  • Basler Electric BE1-11-G6D1M0J2P0E000 / BE111G6D1M0J2P0E000
  • Basler Electric BE1-GPS100-E4N1H1N / BE1GPS100E4N1H1N
  • Eaton Omnex T300-000272 T300 Series Remote Controller
  • EATON ELPRO 450U-E Wireless Ethernet Modem Model: 450U-E-L-440-W
  • Eaton JD3225 Series C complete molded case circuit breaker
  • Eaton HMP-HM64 Crouse-Hinds series MTL HART backplane
  • EATON VICKERS EEA-PAM-523-A-32 02-326001 POWER AMPLIFIER
  • Eaton HTP-SC16M / MTL Hart Multiplexor Connection Unit
  • Eaton XV-152-D6-10TVR-10 150609 Touch Panel
  • Eaton S801+ soft starter S801+N66N3S-MA
  • Eaton Series C complete molded case circuit breaker EHD3015L
  • Eaton V200M4CJC NEMA starter, Space SVG reversing starter
  • EATON CORPORATION CAN-16DI/P / CAN16DIP
  • Eaton Soft Starter S801+N66N3S
  • Eaton Soft Starter S801+N66N3S
  • Eaton XV-303-70-B00-A00-1B Base HMI XV300 Single Ethernet
  • EATON XV-303-70-B00-A00S07 / XV-303-70-B00-A00S07
  • EATON CUTLER-HAMMER MP-3010 SAFETY RELAY 66D2205G01 MP-3000
  • EATON CUTLER HAMMER 92-02123-00 7600C OPERATOR INTERFACE PANELMATE BLIND NODE EP
  • EATON CORPORATION HMCP150T4CBP10 CIRCUIT BREAKER
  • Eaton 142531 XV-102-D6-57TVR-10 Touch Panel
  • EATON ELECTRIC CAN-16DO/0.5A-PK 140254 CanOpen digital output 0.5A
  • EATON XV-102-B5-35TQR-10-PLC 140021 XV102B535TQR10PLC
  • EATON MP-3000 66D2032GX1 NSNP
  • Eaton HFD3150 3P 150A 600VAC Circuit Breaker
  • Eaton Cutler-Hammer HFD3030 6639C86G87 3 Pole 30A 600V Circuit Breaker