Introduction

The GE Multilin 515 Blocking and Test Module has the following features:

• 14 Pole switchbank

• CT inputs short when current switches are opened

• Current injection for each phase

• Ground terminal

• Ability to visually isolate (open) trip relay output circuits

• Cover provided

• Suitable for utility and industrial use

• 515 test plugs available

Description

The 515 Blocking and Test Module provides an effective means of trip blocking,

relay isolation and testing of GE Multilin relays. By opening the switches and inserting test plugs,

phase and residual currents from the primary CTs can be monitored.

Currents can be injected into the relay from a secondary injection test set during commissioning.

Prior to testing, the trip and auxiliary circuits must first be opened to prevent nuisance tripping;

CTs can then be shorted. Conversely, when the test is complete and the relay put back into operation,

the CT switches should be closed first to ensure normal operation of the relay, prior to closing the trip and auxiliary circuits.

Installation

Shorting switches are provided for connection of 3 phase CTs (current transformers) and

a separate core balance ground fault CT or 3 phase CTs connected for residual ground fault sensing.

When each CT switch is opened, the CT is shorted. It is essential that the CT is connected to the

shorted side of the switch as shown in the following figure,

otherwise dangerously high voltages would be present from the open circuited CTs.

When the switches are open, test plugs can be inserted to either inject signals into the

relay wired to the switches or monitor signals such as CT current from the switchgear.

The 515 Blocking and Test Module consists of a metal chassis attached to the 515 test switches that slides into the panel.

A single cutout in the panel, as per the dimensions shown in Figure 3, is required to mount the 515 test switches.

Slide the metal chassis attached to the 515 test switches into the cutout from the front of the panel.

While firmly applying pressure from the front of the 515 module to ensure the chassis fits snugly,

bend out the retaining tabs as shown in Figure 3. Usually the retaining tabs will be sufficient

to hold the 515 module securely in place. If additional fastening is desired bend out the clamping

screw tabs at both ends of the chassis at right angles.

Insert the #8 screws provided in the accessory pouch into the tapped holes with the vibration

proof nut between the tab and the panel. Tighten each screw until the end of the screw butts firmly against the front panel.

Ensure the nut is installed tightly against the bent tab. Nylon inserts in these nuts prevent them from vibrating loose.

The 515 test switch module should now be securely mounted to the panel with no movement ready for rear terminal wiring.

When completed, place the front cover over the mounted 515 test module and turn

the fasteners at both ends ¼ turn to lock it in place, as shown in Figure 3.

As a safety precaution, a ground screw located on the bottom-right of the

rear side of the module is available to be connected to panel chassis ground.

Operation

To put the 515 Blocking & Test Module into operation, additional parts have been provided:

• 1 package containing at least 28 terminal nuts

• 14 white tags for identification of each of the switches

The 515 provides a means of trip blocking, relay isolation, and testing of GE Multilin relays.

The 515 accomplishes this with a total of 14 switches. There are 6 single pole throw

switches for use with the output relays, and 4 groups of 2 switches each for use with the

current transformers as illustrated in Figure 1: Typical Wiring.

Isolation or opening of the relay’s output circuits is accomplished with the six switches

at terminals 1 through 6 and 15 through 20. These switches can be used to simply open

the protection relay's output contacts and thus provide a means of blocking trips.

The 4 remaining groups of 2 switches at terminals 7 through 14 and 21 through 28 are

used for shorting of the CT inputs, injection of test current, and measuring of CT current.

The four groups correspond to Phase 1 Current, Phase 2 Current, Phase 3 Current, and Ground Current.

  • Eaton 1023843 Power Board B20098140711 A5
  • Eaton PDG23F0125VFFJ Power Defense molded case circuit breaker
  • Eaton 9130 1KVA Marine Filter Pn 1029424 Rev 002 220/230/240VAC 50/60Hz 1603
  • Eaton/Dynamatic 15-871-6 AF5000+ Power Supply Board P-CTR 158716
  • EATON D80JE22A PNEUMATIC TIMER SER.A2
  • Eaton - Cutler Hammer PXM1000MB15-1 PXM 1000 METER; DISPLAY; 5A; 100-415AC/1
  • Eaton Cutler Hammer IQDP-4000 IQ DP-4000 66D2040G03
  • Eaton F801 8 Segment Redundant Fieldbus Power Supply
  • Eaton PXM-4KUPG Power Xpert Meter 4000 to 6000 license upgrade key
  • Eaton PX-PMBC Panel mounting bracket assembly required for reduced graphic display rear clearance
  • Eaton PX-PMBB Panel mounting bracket assembly for retrofitting a graphic display to an IQ analyzer cutout
  • Eaton PX-PMBA Panel mounting bracket assembly for back-to-back meter to graphic display mounting
  • Eaton PXMCE-B Communications expansion card: Ethernet 100FX, 10/100T, RS-485, RS-232
  • Eaton PXMIO-B Digital I/O card: 8 digital input, 2 solid-state output, 3 relay output
  • Eaton PXD-MMG Graphic display module
  • Eaton PXM4051A1AB Power Xpert meter 4000
  • Eaton / Cutler Hammer PXM4000 PXM4051A1BB
  • Basler Electric BE1-59-A4E-E1C-A0N0F / BE159A4EE1CA0N0F Over Voltage Relay
  • Basler Electric SR4A-2B05A3E Static Voltage Regulator SR4A2B05A3E
  • Basler Electric 9-0723-00-130 / 9072300130
  • Basler Electric BE1-79MA10A6JC0L0F / BE179MA10A6JC0L0F
  • Basler Electric CBS-377 CURRENT BOOST SYSTEM PART NO 91096001
  • Basler Electric SR4A1B05A3A Static Voltage Regulator 480v-ac 62.5v-dc 10va
  • Basler Electric BE159N A7ED1JC0S0F Solid State BE159N-0 Protective Relay
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K2EW6MB1N0F
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50 Style G4EA1RG0N0F
  • Basler Electric BE1A-25-M1G-A6T-N4V1F Sync-Check Relay
  • Basler Electric SR8A2B10B1A STATIC VOLTAGE REGULATOR
  • BASLER TIME OVERCURRENT RELAY BE1-51A SOLID STATE 1 PH
  • Basler Electric SSR 125-12 STATIC VOLTAGE REGULATOR 9185900102
  • Westinghouse 2374A07G03 Power Supply Basler Electric 90-73900-102
  • 9400200117 - Basler Electric - CONTROL POWER UNIT - 12/24VDC 20WATT
  • Basler Electric Static Voltage Regulator SR32A2B05B3E
  • Basler Electric SR8A2B06B3A Static Voltage Regulator / SR8A2BO6B3A
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY B1EZIPB1N0F
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50-51B-219
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EW6MB0N0F
  • Basler Electric SBO226 Excitation Support System
  • Basler Electric SBO225 Excitation Support System
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EZ1PA0N0F
  • Basler Electric MOC3502 | 90-72300-116 MOTOR POTENTIOMETER
  • Woodward 1751-6058 4 Channel MPU Transformer Module
  • Basler Electric 2D80367G23 DXCB De-Excitation Module 1200V 5000A Excite
  • Basler Electric SSR 63-12-9185900101 Static Voltage Regulator
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EW5MB0N0F
  • Basler Electric MODEL SSR 125-12NF STATIC VOLTAGE REGULATOR 9 1859 00 106
  • Basler Electric Breaker Protection Relay BE1-BPR 9272000315
  • Basler Electric SBO224 Excitation Support System
  • Basler Electric SSR 63-12 Static Voltage Regulator 9 1859 00 101 46534AB
  • Basler Electric AEM-2020 ANALOG EXPANSION MODULE
  • Basler Electric BE 25231-001 Transformer BE25231001
  • Basler Electric PSS-100-Y5 Power Sys Stabilizer dampening oscillations 0.1-5.0Hz
  • Basler Electric BE1-87G-S1A-A1C-A0N0 Variable Percentage Differential Relay
  • Basler Electric SR8A-2B06B3E Static Voltage Regulator SR8A2B06B3E
  • Basler Electric SOLID STATE FREQUENCY CONTROLLER SCP-210 /SCP210 P/No:9095400100
  • Basler Electric BE1-59-A3E-A1J-N1N3F / BE159A3EA1JN1N3F Over Voltage Relay
  • Basler Electric SBO223 Excitation Support System
  • Basler Electric P/N 9 2011 11 100 BRACKET MOUNTED TERMINAL UNIT
  • Basler Electric P/N 9 2011 11 100 BRACKET MOUNTED TERMINAL UNIT
  • Basler Electric voltage regulator P/n: 9 1606 00 101
  • Basler Electric Current Boost System | Model No. CBS-377 P/N 9109600102
  • Basler Electric 8650C72 Exciter Control Module Pcb Board Rev 5
  • Basler Electric 9252000258 Be1-50/51b Overcurrent Relay
  • Basler Electric SR8A-2B01B3A Static Voltage Regulator SR8A2B01B3A
  • Basler Electric SR4A-2B01B3E Static Voltage Regulator SR4A2B01B3E
  • Basler Electric 9017709102 PC Board
  • Basler Electric 9066800102 Excitation Support Systems 9066800-102
  • Beckhoff ELX3152-0090 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELX3158 | EtherCAT Terminal, 8-channel analog input, current, 4…20 mA
  • Beckhoff ELX3152 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3704-1001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0020 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3702-0101 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3702-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3604-0002 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3604-0000 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0032 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0030 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0002 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0000 | EtherCAT Terminal, 2-channel analog input
  • Beckhoff ELM3544-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3542-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • ENOTEC GAS ANALYZER SYSTEM OXITEC 5000 SME-53310000
  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch