Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

GE Grid Solutions 515 Blocking and Test System

From:GE | author:Mr.Chen | Time :2025-01-17 | 536 view: | 🔊 Click to read aloud ❚❚ | Share:

Introduction

The GE Multilin 515 Blocking and Test Module has the following features:

• 14 Pole switchbank

• CT inputs short when current switches are opened

• Current injection for each phase

• Ground terminal

• Ability to visually isolate (open) trip relay output circuits

• Cover provided

• Suitable for utility and industrial use

• 515 test plugs available

Description

The 515 Blocking and Test Module provides an effective means of trip blocking,

relay isolation and testing of GE Multilin relays. By opening the switches and inserting test plugs,

phase and residual currents from the primary CTs can be monitored.

Currents can be injected into the relay from a secondary injection test set during commissioning.

Prior to testing, the trip and auxiliary circuits must first be opened to prevent nuisance tripping;

CTs can then be shorted. Conversely, when the test is complete and the relay put back into operation,

the CT switches should be closed first to ensure normal operation of the relay, prior to closing the trip and auxiliary circuits.

Installation

Shorting switches are provided for connection of 3 phase CTs (current transformers) and

a separate core balance ground fault CT or 3 phase CTs connected for residual ground fault sensing.

When each CT switch is opened, the CT is shorted. It is essential that the CT is connected to the

shorted side of the switch as shown in the following figure,

otherwise dangerously high voltages would be present from the open circuited CTs.

When the switches are open, test plugs can be inserted to either inject signals into the

relay wired to the switches or monitor signals such as CT current from the switchgear.

The 515 Blocking and Test Module consists of a metal chassis attached to the 515 test switches that slides into the panel.

A single cutout in the panel, as per the dimensions shown in Figure 3, is required to mount the 515 test switches.

Slide the metal chassis attached to the 515 test switches into the cutout from the front of the panel.

While firmly applying pressure from the front of the 515 module to ensure the chassis fits snugly,

bend out the retaining tabs as shown in Figure 3. Usually the retaining tabs will be sufficient

to hold the 515 module securely in place. If additional fastening is desired bend out the clamping

screw tabs at both ends of the chassis at right angles.

Insert the #8 screws provided in the accessory pouch into the tapped holes with the vibration

proof nut between the tab and the panel. Tighten each screw until the end of the screw butts firmly against the front panel.

Ensure the nut is installed tightly against the bent tab. Nylon inserts in these nuts prevent them from vibrating loose.

The 515 test switch module should now be securely mounted to the panel with no movement ready for rear terminal wiring.

When completed, place the front cover over the mounted 515 test module and turn

the fasteners at both ends ¼ turn to lock it in place, as shown in Figure 3.

As a safety precaution, a ground screw located on the bottom-right of the

rear side of the module is available to be connected to panel chassis ground.

Operation

To put the 515 Blocking & Test Module into operation, additional parts have been provided:

• 1 package containing at least 28 terminal nuts

• 14 white tags for identification of each of the switches

The 515 provides a means of trip blocking, relay isolation, and testing of GE Multilin relays.

The 515 accomplishes this with a total of 14 switches. There are 6 single pole throw

switches for use with the output relays, and 4 groups of 2 switches each for use with the

current transformers as illustrated in Figure 1: Typical Wiring.

Isolation or opening of the relay’s output circuits is accomplished with the six switches

at terminals 1 through 6 and 15 through 20. These switches can be used to simply open

the protection relay's output contacts and thus provide a means of blocking trips.

The 4 remaining groups of 2 switches at terminals 7 through 14 and 21 through 28 are

used for shorting of the CT inputs, injection of test current, and measuring of CT current.

The four groups correspond to Phase 1 Current, Phase 2 Current, Phase 3 Current, and Ground Current.

  • Prosoft PLX82-EIP-61850 EtherNet/IP™ Server to IEC 61850 Client Gateway
  • PROSOFT TECHNOLOGY PROLINX 5604-RIO-PDPMV1
  • 5201-104S-MCM ProSoft Technology IEC 60870-5-104 Server to Modbus
  • 5104-MCM-PDPMV1 ProSoft Modbus Master/Slave to PROFIBUS DPV1 Master Gateway
  • Prosoft AN-X2-AB-DHRIO Gateway
  • Prosoft RLX2-IFH24E Industrial Wireless Ethernet Radio
  • Prosoft ICX35-HWC Industrial Cellular Gateway
  • Prosoft 5202-DFNT-MCM4 EtherNet/IP to Modbus Master/Slave Gateway
  • Prosoft PLX35-NB2 Network Bridge
  • ProSoft 4204-DFNT-PDPM ProLinx Gateway Ethernet/IP to Profibus-Master V2.45
  • Prosoft 6105-WA-PDPS Wireless PROFIBUS Gateways
  • Prosoft 6104-WA-PDPM Wireless PROFIBUS Gateways
  • Prosoft PTQ-PDPMV1 Master module
  • Prosoft MVI56-LTQ Limitorque Valve Network Interface Module
  • Prosoft 4301-MBP-DFCM Modbus Plus to DF1 Master/Slave Gateway
  • Prosoft 5201-MNET-MCM-WEB Modbus Plus to DF1 Master/Slave Gateway
  • Prosoft 5304-MBP-PDPMV1 Modbus Plus to DF1 Master/Slave Gateway
  • Prosoft 5302-MBP-MCM4 Modbus Plus to DF1 Master/Slave Gateway
  • Prosoft 5301-MBP-DH485 Modbus Plus to DF1 Master/Slave Gateway
  • PROSOFT ANC-100E Ethernet connectivity module
  • Prosoft 5304-MBP-PDPM Modbus Plus to DF1 Master/Slave Gateway
  • ProSoft 1452-25M Transfer Module
  • Prosoft MVI56-MNETR Modbus TCP/IP Interface Module
  • Prosoft MVI69L-MBS Modbus TCP/IP Interface Module
  • Prosoft PLX32-EIP-SIE Ethernet Communication Gateway
  • 5602-RIO-MCM4 ProSoft Rockwell Automation Remote I/O
  • Prosoft MVI56-PDPS Modbus TCP/IP Interface Module
  • Prosoft PMF1327205 Network Interface Module
  • Prosoft PMF1216D61 Network Interface Module
  • Prosoft MVI56-GSC Modbus TCP/IP Interface Module
  • PROSOFT 5601-RIO-MCM Communication Gateway Brand
  • Prosoft MVI56-MDA4 input/output module
  • Vibro-meter VM600-RPS6U 113-40060 Industrial Control Module
  • Vibro-meter MPC4 200-510-071-113 machinery protection card
  • vibrom-meter VM600 MPC4 machinery protection and condition monitoring module
  • vibrom-meter MPC4 200-510-076-115 Four-channel machine protection controller
  • Vibro-meter 200-510-111-035 MPC4 mechanical protection card
  • Vibro-meter MPC4 200-510-078-115 Meggitt Sensing Systems
  • Vibro-meter VM600 IOC4T | PNR200-560-000-111 | input/output card
  • Vibro-Meter VM600 PNR200-570-000-111 Industrial Monitoring Module
  • Vibro-meter VM600 IOCN PNR200-566-000-112 Industrial Control Module
  • Vibro-meter VM600 IOC16T PNR200-565-000-013 Industrial Control Module
  • Vibro-meter VM600 RPS6U PN200-582-500-013 Power Supply Module
  • Vibro-meter VM600 CMC16 PNR200-530-022-014 Communications Management Controller
  • Vibro-meter VM600-ABE040+204-040-100-011 measurement module
  • Vibro-meter 204-040-100-012 VM600 system rack
  • Vibro-meter vmf-IOCN 200-566-101-013 200-566-000-112 communication interface card
  • 4000094-310 | Triconex | External Output Cable Aassembly
  • TRICONEX AO3482 | Analog Output Safety Module
  • TRICONEX AT-2701FX 843-000844-00 REVD Ethernet Fiber Optic Network Interface Card
  • TRICONEX D28799-005 Power Interface Module
  • Triconex DI3361 Digital Input Module Brand
  • Triconex AI2361 7400210-020 Analog Input Card Module
  • Triconex AI3351 Analog Input Card Module
  • Triconex 4351A TCM Communication Module
  • TRICONEX RO3451 Digital Input Module Brand
  • TRICONEX 4000093-320 communication module
  • TRICONEX 2071H 7400313-100 Data Acquisition Module
  • TRICONEX T8800C PD8800 PCB130100 RISC Processor
  • TRICONEX 4000093-316 communication module
  • TRICONEX 4000094-313 communication module
  • TRICONEX 4000093-306 communication module
  • TRICONEX 4000103-513 communication module
  • TRICONEX 4000093-145 communication module
  • Triconex 4000066-025 9000011-000 I/O Communication Bus Cable
  • Triconex 4000056-025 I/O Communication Bus Cable
  • TRICONEX 4000093-110N Main Processor Module
  • Triconex 4352AN Tricon Communication Module
  • Triconex T8830 Control Module
  • Triconex 3008N Control Module
  • TRICONEX TCM 4355X Control Module
  • Triconex MP3009X/TCM 4355X Industrial Control Module
  • TRICONEX PLM 3900N Safety Redundant I/O Module
  • TRICONEX DI 3506X Digital Input Interface Board
  • TRICONEX IMSS 4701X I/O bus interface module
  • TRICONEX 7400212-100 Safety I/O Module
  • TRICONEX 2000418 Three-Channel Redundancy Module
  • TRICONEX 2000417 Three-Channel Redundancy Module
  • TRICONEX 3625C1 | Digital Output Module
  • TRICONEX TM11-5L-88 Industrial Control Module
  • TRICONEX 09031647921 | TMR Digital Output Module
  • TRICONEX JWA600-24 Digital Input Module
  • TRICONEX 9753-1 Redundant I/O Module
  • TRICONEX FTA-554 Process Control Module
  • TRICONEX 9853-610 Analog Output Module
  • 9662-1 TRICONEX terminal block
  • TRICONEX 2290614 Analog module
  • 3625A | Triconex | Digital 24VDC Output Module
  • T8850C | ICS Triplex Expander Interface Module
  • TRICONEX 8311N Power Module
  • TRICONEX 3708EN High-Precision Redundant Analog Input Module
  • TRICONEX 8609-396-7113755 Triple Modular Redundancy
  • TRICONEX 0905-148-6921 16-Channel Digital I/O Module
  • TRICONEX 0903-164-7921 16-Channel Digital I/O Module
  • TRICONEX 0923-141-6957 Triple Modular Redundancy
  • Triconex 8110 High Density Main Chassis
  • TRICONEX PM6301A analog output module
  • GE Converteam P111-6052 Advanced Micro Controller
  • AI6700 - Triconex Analog Input Module
  • TRICONEX ICM6211 Industrial Control Module
  • DI6503 TRICONEX Digital Input Module
  • TRICONEX 1600071-001 Terminal Board
  • 9662-910 | TRICONEX | Digital Input Terminal Panel
  • 9661-610 | TRICONEX | Digital Input Terminal Panel
  • Triconex 7400206-100 CM2201 Communication Module
  • Triconex 4000056-002 I/O Communication Bus Cable
  • TRICONEX 7400213-100 Digital signal Hardware execution unit
  • TRICONEX | HCU3700/3703E | Isolated Analog Input suppliers
  • Triconex 7400209-010 AO2481 Analog Output Module
  • TRICONEX 3005 Pulse Input Terminal Board
  • TRICONEX 3002 Pulse Input Terminal Board
  • QY68A - I-O Units (Mitsubishi Electric) - Mitsubishi Electric
  • QH42P | Mitsubishi Electric | I/O Combined Module
  • Mitsubishi Q Series Cc-Link Ie Qj71gp21s-Sx PLC Controller
  • Mitsubishi Electric QJ61BT11 Sequencer (MELSEC-Q) CC-Link system master local unit
  • Q68DAIN - Mitsubishi Analog Input Module
  • QJ71C24N-R2 | Mitsubishi Electric | Interface Module
  • Digital Input Module Mitsubishi RX10-TS
  • Mitsubishi PLC CPU Module Q Series Q13UDEHCPU
  • Mitsubishi Q12HCPU Series CPU Module
  • Mitsubishi Electric Q02HCPU Q Series High Speed Q CPU Module
  • Mitsubishi NP1S-22 POWER SUPPLY MODULE
  • Q61P-A1 Power Supply Systems by MITSUBISHI
  • Q63P Mitsubishi Electric | Mitsubishi Electric Q63 Series PLC Power Supply
  • Q64P Power Supply Systems by MITSUBISH
  • Q61P-A2 MITSUBISHI Power Supply PLC
  • Melsec-q Series Mitsubishi Q61P Power Supply PLC
  • Q38B - Mitsubishi Base Rack at Rs 12000