Introduction
The Ethernet I/O Card (EIOC) provides a platform to access data
from Ethernet devices in the DeltaV™ system. Ethernet Devices
capable of talking Modbus TCP, EtherNet/IP, IEC 61850 MMS
(Manufacturing Message Specification), OPC UA client and
EtherNet/IP Control Tag Integration protocols are supported.
The EIOC provides monitoring and control of Ethernet Devices
on the Ethernet Device Network via control modules assigned
to and executed in the EIOC. Ethernet Devices like PLCs,
Motor Control Centers, drives, switchgear and others can be
controlled directly by the EIOC, independent of a controller.
Benefits
Ability to communicate directly to Ethernet Device
Networks. Use the EIOC to monitor and control
Ethernet Devices.
Powerful and Scalable. The EIOC allows a huge amount of
data coming from Ethernet Devices to be accessed in DeltaV,
and is scalable to fit your needs with licensing based on the
number of devices you connect. The EIOC can bring:
• Up to 32,000 signals from 256 Ethernet Devices when
using Modbus TCP, EtherNet/IP, or IEC61850 MMS.
• Up to 30,000 signals from 64 Ethernet Devices when
using OPC UA client protocol.
• Up to 2000 tags (10 signals per tag) from 256 Ethernet
Devices when using EtherNet/IP Control Tag
Integration Protocol.
Monitoring. Data values integrated into the EIOC can
be used in Control Modules running inside the EIOC.
These control modules allow alarm generation,
history collection, and viewing by the operator,
as with control modules running in a Controller
using traditional DeltaV native I/O.
Supports control functionality. In addition,
function blocks allowing for discrete control and limited
PID control are supported for the EIOC. No assignment to a
controller is required. Motors, switchgear, variable frequency
drives; or any device that communicate via Ethernet
protocols can be controlled directly from the EIOC.
Easy to connect to Ethernet Devices using Modbus TCP,
EtherNet/IP, IEC61850 MMS, OPC UA client and EtherNet/
IP Control Tag Integration protocols. Use the EIOC Ethernet
protocols to connect your DeltaV system to your Ethernet
Device Networks.
Huge processing capacity. Each EIOC is capable of handling
a huge amount of Data in up to 2000 Control Modules.
EIOC is part of the DeltaV Control Network. 60 EIOC’s
can be added directly to the DeltaV Control Network,
allowing maximum freedom in segregating your networks.
Flexible networking. User configurable IP addressing for
the Ethernet Device Network allows the EIOC to be used in
almost any plant environment regardless of the networking
scheme. When designing a simplex Ethernet Device Network,
consider that the EIOC and the Ethernet Devices must be on
the same IP subnet to communicate. Also, when designing
a redundant Ethernet Device Network, consider that the
primary and secondary ports in the EIOC must be in different
subnets to follow best engineering practices.
Easy to use. The EIOC is easy to use as it provides a native
way to bring Ethernet protocol data into the DeltaV system.
Specific ease of use features include:
• You can choose between the 5 different Ethernet
protocols supported in the EIOC. Only one protocol is
supported at a time and requires the proper licensing.
• Updates for the EIOC and drivers are included
within DeltaV.
• Configured in DeltaV Explorer. All needed configuration
for the Ethernet Devices is done in DeltaV Explorer and
DeltaV Control Studio, just like Traditional I/O signals.
The data can be configured in DeltaV Control Modules,
displayed on DeltaV Live and DeltaV Operate graphics,
and stored in the DeltaV Continuous Historian.
Modular and Easy to add Redundancy. The dual horizontal
carrier hosts all the needed components for a redundant
setup (redundant Power input Terminals and redundant
Ethernet Isolation ports). The EIOC becomes redundant
wechat/whatsapp: