Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

Euresys Coaxlink Quad CXP-12 Value

From:Euresys | author:Mr.Chen | Time :2024-10-31 | 326 view: | Share:

Advantages

PCIe 3.0 (Gen 3) x8 bus

- 7,800 MB/s peak bus bandwidth

- 6,700 MB/s sustained bus bandwidth

Connect the fastest, highest resolution cameras to capture images

- Highest data acquisition rate in the industry

- 50 Gbit/s (5,000 MB/s) bandwidth (from camera to host PC memory)

Long cable support

- 40 metres at CXP-12 speed (12.5 Gbps)

- 72 metres at CXP-6 speed (6.25 Gbps)

- 100 metres at CXP-3 speed (3 Gbps)

Power over CoaXPress

- Power over CoaXPress: The camera delivers up to 17 W per channel with 24 VDC and provides automatic device detection, measurement and overload protection.

- Total voltage and current as well as voltage and current per channel can be measured for verification and performance deviation monitoring.

Uses standard coaxial cable

- Data transfer, camera control, triggers and power supply with a single, inexpensive cable

- Top-notch reliability and flexibility for implementation in harsh environments

Micro-BNC (HD-BNC™) connectors provide reliable connections

- Trusted push-to-turn snap ring positive locking

- For quick and easy connection and disconnection

Connects up to 4 cameras to a single Coaxlink card

Memento Event Logging Tool

- Memento is an advanced development and debugging tool for Coaxlink and Grablink cards.

- Memento records an accurate log of all events related to the camera, the frame grabber card and its driver, and the application.

- For times containing timestamps, it provides developers with accurate timelines, as well as contextual information and logic analyser views.

- It can provide valuable collaboration during application development and debugging, as well as during machine operation.

Direct GPU Transfer

- Sample programs are available for AMD DirectGMA and NVIDIA (CUDA).

- GPU Direct Transfer eliminates unnecessary copies of system memory, reduces CPU overhead, and decreases latency, resulting in significant improvements in application data transfer times.

- Use AMD's DirectGMA to capture image data directly to GPU memory. Compatible with AMD FirePro W5x00 and higher and all AMD FirePro S series products.

Universal I/O Cable

- Compatible with a wide range of sensors and motion encoders

- Eight isolated current sense inputs (up to 30V, signalling up to 200kHz, individually galvanically isolated up to 250VDC and 170VAC RMS)

- Four high-speed differential inputs (quadrature motion encoder support up to 5 MHz)

- Four isolated tactile outputs (up to 30V, 100 mA, signalling up to 100 KHz)

- Four high-speed 5V-compatible TTL inputs/LVTTL outputs (signalling up to 5 MHz)

High performance DMA (Direct Memory Access)

- Direct transfers to user-allocated memory and hardware boards displaying PCI addresses

- Hardware Dispersal - Aggregation Support

- 64-bit addressing capability

Area Scan Trigger Function

- Triggers are used to initiate acquisition when a part is in place. Hardware triggers come from Coaxlink's I/O lines. Software triggers are from the application.

- Controllable delay triggers to control the point at which image acquisition is delayed.

- Trigger extraction feature allows certain triggers to be skipped.

- Camera exposure control allows the application to control the exposure time of the camera.

- When the system starts to acquire images, the Coaxlink capture card generates a signal at an appropriate point in time to control the lighting equipment connected to the output.

Line Scan Trigger Capability 1/2

Coaxlink supports both continuous roll scanning (to inspect infinite, continuously moving surfaces without losing lines) and discrete target scanning (to capture images of targets moving in front of the camera).

(to capture images of targets moving in front of the camera).

- Triggers are used to initiate acquisition when the part is in position. Hardware triggers are from the motherboard I/O lines. Software triggers come from the application.

- Once initiated, the acquisition will continue indefinitely (for rolling the network):

- Continue indefinitely (for rolled-net monitoring applications)

- continue for a programmable number of lines (to acquire a target image of known length)

- continue until an end trigger signal is received (to acquire variable length target images)

  • Emerson PMCSPANA/IH PMC Carrier Installation and Use Manual
  • Emerson PMCSPAN26E-010 Secondary PMC expansion
  • Emerson PMCSPAN26E-002 Primary PMC expansion
  • Emerson PMCSPAN16E-010 Secondary PCI expansion
  • Emerson PMCSPAN16E-002 Primary PCI expansion
  • A-B 1783-HMS4C4CGN Stratix 5400 Ethernet Managed Switches
  • A-B 1783-RA5TGC4G Stratix 4300 Remote Access Routers
  • A-B 1783-CMS10DP Stratix 5200 Ethernet Managed Switches
  • A-B 1783-CMS20DP Stratix 5200 Ethernet Managed Switches
  • A-B 1783-CMS20DP Stratix 5200 Ethernet Managed Switches
  • A-B 1783-HMS8S4CGN Stratix 5400 Ethernet Managed Switches
  • A-B 1783-CMS6B Stratix 5200 Ethernet Managed Switches
  • A-B 1783-RA5TGW Stratix 4300 Remote Access Routers
  • A-B 1783-RA2TGWC4G Stratix 4300 Remote Access Routers
  • A-B 1783-US8T/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US5TG/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-RA2TGW Stratix 4300 Remote Access Routers
  • A-B 1783-US8T/A Stratix 2000 Ethernet Unmanaged Switches—Series A
  • A-B 1783-US6T2F/A Stratix 2000 Ethernet Unmanaged Switches—Series A
  • A-B 1783-US4T1F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US5TG Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US4T1H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2TG2H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US5T/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US6T2TG2F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2H/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US4T1H/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US14T2S Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US7T1H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US16T2S Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-RA2TGC4G Stratix 4300 Remote Access Routers
  • A-B 1783-US16T/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US7T1F/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-RA2TGB Stratix 4300 Remote Access Routers
  • A-B 1783-LMS5 Stratix 2500 Ethernet Lightly Managed Switches
  • A-B 1783-US7T1F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US4T1F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US16T Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US8T Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2H/A Stratix 2000 Ethernet Unmanaged Switches—Series A
  • A-B 1783-US4T1F/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US8TG2GX Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US5T 5 Port Unmanaged Switch
  • MOOG D138-002-002 Industrial Control Module
  • MOOG D138-003-001 Industrial Control Module
  • MOOG CA98502-001 Accessories for Ruggedized Motion Controller
  • MOOG D691-078D servo valve
  • MOOG CA65866-001 MSD Motion Controller
  • MOOG C43148-001 QD10 16/16 Digital l/0 module
  • MOOG D138-002-012 Main control unit
  • MOOG CA94286-001 Accessories for Ruggedized Motion Controller
  • MOOG D136-001-008 MSCI MSD Motion Controller
  • MOOG B95906-001 MSCI Motion Controller
  • MOOG B95865-001 CAN Termination Resistors
  • MOOG QEBUS-CAN Module
  • MOOG D136-003-001 Interfaces of Ruggedized Motion Controller
  • MOOG RDI0 16/16 Digital Module
  • MOOG D136-003-004 Interfaces of Ruggedized Motion Controller
  • MOOG D391-001-003 MSD MOTION CONTROLLER
  • MOOG D138-002-003 Industrial Control Module
  • MOOG MSC-R-10 16/8 Digital and PT100 Module
  • MOOG CB08987-001 Ruggedized Motion Controller
  • MOOG RDISP 22 Operator Panel DISPLAYS
  • MOOG D136-003-002 Interfaces of Ruggedized Motion Controller
  • MOOG CA65865-001 MSCl Motion Controller
  • MOOG B95863-001 CAN Connection Cables
  • MOOG QA10 16/4 Analog Module
  • MOOG D136-006-001 EtherCAT slave interface
  • MOOG D391-001-001 MSD MOTION CONTROLLER
  • MOOG D136-003-005 Interfaces of Ruggedized Motion Controller
  • MOOG D137-004-003 TFT Touch screen display
  • MOOG D138-002-003 Industrial Control Module
  • MOOG D138-003-010 Industrial Control Module
  • MOOG CB03223-001 Accessories for Ruggedized Motion Controller
  • MOOG B95864-001 CAN Termination Resistors
  • MOOG QD10 16/16 Digital Module
  • MOOG D391-001-002 MSD MOTION CONTROLLER
  • MOOG D138-001-010 Industrial Control Module
  • MOOG D138-001-005 Industrial Control Module
  • MOOG D138-001-002 Industrial Control Module
  • MOOG D138-001-001 Industrial Control Module
  • MOOG D137-002-001 Digital I/O modules
  • MOOG QEBUS-CAN Extension module
  • MOOG D137-001-010 Connection modules
  • MOOG D137-001-004 Digital I/O modules for E-Bus
  • MOOG D137-001-007 Digital extension module
  • MOOG G391-001-001 MSD Motion Controller
  • MOOG D138-002-001 Motion Controller
  • MOOG D137-004-004 TFT Touch screen display
  • MOOG D136-002-005 Ruggedized Motion Controller Interface
  • MOOG D137-001-006 Digital extension module
  • MOOG D136-002-004 Ruggedized Motion Controller Interface
  • MOOG D137-004-006 TFT Touch screen display
  • MOOG G391-001-002 MSD Motion Controller
  • MOOG D137-004-005 TFT Touch screen display
  • MOOG D137-001-005 Digital extension module
  • MOOG D136E001-001 Programmable Processor Module
  • MOOG D138-006-001 operation panel
  • MOOG G122-829-001 Programmable Processor Module
  • MOOG G761-3002B Industrial servo valves
  • MOOG T161-902A-00-B4-2-2A Servo Controller
  • MOOG M128-010-A001B DC Power Module
  • MOOG G391-001-003 MSD Motion Controller
  • MOOG D138-002-002 Motion Controller
  • MOOG D137-001-011 Digital extension module
  • MOOG D136-002-003 Ruggedized Motion Controller Interface
  • MOOG D136-002-002 Ruggedized Motion Controller Interface
  • MOOG D136-001-008a Ruggedized Motion Controller Interface
  • MOOG D136-001-007 Ruggedized Motion Controller Interface
  • MOOG D136-001-001 Ruggedized Motion Controller Interface
  • MOOG 914-GBE Gigabit Ethernet (GbE) Media Converter
  • MOOG 914-0300-00 ADVANCED MODULAR MULTIPLEXER SYSTEM
  • ABB UCD224A103 digital input/output module
  • ABB PDD205A0121 power distribution device
  • ABB PDD205A1121 power distribution device
  • ABB DSDX453 Digital input/output (DIO) expansion card
  • ABB DSPC454 Processor Board
  • ABB 81EU01E-E Input Module
  • ABB TK457V050 Temperature Controller
  • ABB DSRF197K01 Ethernet communication module
  • ABB TK802F power supply cable
  • ABB 3BHE039203R0101 IGCT module board
  • ABB 3BHB004027R0101 IGCT module board
  • ABB 3BHB003154R0101 IGCT module board
  • ABB PM864AK01-eA Processor Unit
  • ABB CI868K01-eA high-performance communication module