Basler Electric BE1-BPR Breaker Protection Relay

From:Basler Electric | author:Mr.Chen | Time :2026-08-19 | 195 view: | 🔊 Click to read aloud ❚❚ ▶ | Share:

Introduction

BE1-BPR Breaker Protection Relays are three-phase and neutral, 

microprocessor based relays designed to provide power systems 

with protection and security against monitored breaker failure or

to initiate multiple shot breaker reclosings.

These relays incorporate a powerful means of programming internal

relay logic to satisfy a wide range of user requirements without making

any relay hardware changes. Microprocessor-based design provides

the basic features of a programmable logic controller (PLC) combined

with an instantaneous overcurrent module.

Cased in a 19 inch rack-mount or a vertical panel mount, the relay offers

installation versatility. A wide temperature, 2 lines by 16 character display

provides diagnostic and setup information. Two RS-232 serial ports (one

each front and rear) and one RS-485 serial port (rear) provide remote

communication and relay control.

Built-in diagnostics and monitoring features provide information for both

the health of the relay and the health of the breaker being monitored.

Relay diagnostics include continuous background monitoring of the

power supplies, analog-to-digital (A/D) converter, random-access memory

(RAM), read-only memory (ROM), and electrically-erasable programmable

ROM (EEPROM). A dedicated alarm (ALM) relay output provides power 

supply, microprocessor, and software alarm status. Breaker diagnostics

include a timing diagnostic log, breaker contact duty monitoring, breaker

resistor protection, and breaker arc detection.

Other monitoring features include oscillographic fault records and fault

summary logs. BE1-BPR relays use the Inter-Range Instrumentation Group

(IRIG), Format B for high timing accuracy and resolution.

Application - Standard Models

Breaker Failure

BE1-BPR relays are intended to provide a preprogrammed solution for most

breaker failure relaying applications. Breaker failure relaying is the use of a

current monitoring relay to determine whether or not current continues to

flow into a faulted circuit after a breaker has been instructed to interrupt the

circuit. If current continues to flow into the faulted circuit after a defined

period of time has elapsed (sufficient for the breaker to have interrupted the

current), the circuit breaker is considered to have failed. Steps must then be

taken to trip the next set of breakers in the power system to prevent system

damage. Breaker failure schemes must be designed to isolate both the faulted

circuit and the failed breaker.

Several reasons why a breaker fails to clear a fault are:

• Trip circuit is open (broken wire, blown fuse, open trip coil).

• Interrupting mechanism stuck, leaving a single phase of a three-phase circuit

connected.

• Interrupter flash-over due to the loss of dielectric strength through

contamination or damage.

• Operating mechanism failed to operate.

Breaker failure relays detect these conditions and initiate backup procedures.

Breaker failure relays are applied on a per breaker basis. That is, one breaker

failure relay for each breaker in the substation. BE1-BPR relay outputs must be

arranged to initiate the tripping of all the circuit breakers necessary to isolate

the fault if the protected circuit breaker fails to operate. The relay may also

need to initiate transfer tripping of remote breakers to accomplish this task.

Transfer tripping of the remote line end for a breaker failure should also block

reclosing of the remote circuit breakers. External lockout  relays are typically

used to trip and block reclosing of the backup breakers because they normally

require a positive operator action to reset them.

Typically, breaker failure protection is applied to transmission and sub-transmission

systems. However, breaker failure protection may be applied to any portion of the

power system where failure of a circuit breaker to operate properly could result in

severe system damage or instability. Breaker failure protection can also be used to

selectively clear a failed breaker in a station with multiple buses without clearing

the entire station.

Breaker Reclosing

BE1-BPR relays can be configured as multiple shot reclosing relays that operate in

parallel and independently from the breaker failure function.

Three major factors should be considered when establishing a reclosing philosophy.

• Desired number or reclosure attempts.

• Time delay between breaker opening and reclosure.

• Supervisory control.

The first major factor is the desired number of reclosure attempts. Where most

faults are attributable to heavy tree exposure, as in distribution networks, multiple

reclosure attempts are common. This is possible because of low voltage levels and

is desirable considering customer inconvenience during outages. BE1-BPR relays

are programmable for up to three reclosure attempts per sequence. This allows

tailoring of the reclosing sequence to the specific needs of the circuit.

The second major factor is the time delay between breaker opening and reclosure.

On sub-transmission and distribution networks, it is necessary to ensure that motors

are no longer running and that local generation is off-line prior to attempting reclosure.

At the same time, a rapid reclosure minimizes damage, ionization, and system shock

in transmission networks. After the first reclosure attempt, additional attempts are

generally delayed to allow for de-ionization of the interrupter. BE1-BPR relays have

three reclosing shots and each shot has a programmable time delay. 

Three outputs are available. They are CLOSE, RECLOSE FAIL, and LOCKOUT.

A third major factor to be considered in reclosing is supervisory control. Supervisory

control allows the operator to maintain control of the system at all times. BE1-BPR

relays have two supervisory inputs (WAIT and LOCKOUT). WAIT stops the reclose

sequence at any point and allows the sequence to continue when the WAIT input is

removed. LOCKOUT drives the reclose function immediately to lockout status and

takes precedence over all other inputs.

  • Eaton 1023843 Power Board B20098140711 A5
  • Eaton PDG23F0125VFFJ Power Defense molded case circuit breaker
  • Eaton 9130 1KVA Marine Filter Pn 1029424 Rev 002 220/230/240VAC 50/60Hz 1603
  • Eaton/Dynamatic 15-871-6 AF5000+ Power Supply Board P-CTR 158716
  • EATON D80JE22A PNEUMATIC TIMER SER.A2
  • Eaton - Cutler Hammer PXM1000MB15-1 PXM 1000 METER; DISPLAY; 5A; 100-415AC/1
  • Eaton Cutler Hammer IQDP-4000 IQ DP-4000 66D2040G03
  • Eaton F801 8 Segment Redundant Fieldbus Power Supply
  • Eaton PXM-4KUPG Power Xpert Meter 4000 to 6000 license upgrade key
  • Eaton PX-PMBC Panel mounting bracket assembly required for reduced graphic display rear clearance
  • Eaton PX-PMBB Panel mounting bracket assembly for retrofitting a graphic display to an IQ analyzer cutout
  • Eaton PX-PMBA Panel mounting bracket assembly for back-to-back meter to graphic display mounting
  • Eaton PXMCE-B Communications expansion card: Ethernet 100FX, 10/100T, RS-485, RS-232
  • Eaton PXMIO-B Digital I/O card: 8 digital input, 2 solid-state output, 3 relay output
  • Eaton PXD-MMG Graphic display module
  • Eaton PXM4051A1AB Power Xpert meter 4000
  • Eaton / Cutler Hammer PXM4000 PXM4051A1BB
  • Basler Electric BE1-59-A4E-E1C-A0N0F / BE159A4EE1CA0N0F Over Voltage Relay
  • Basler Electric SR4A-2B05A3E Static Voltage Regulator SR4A2B05A3E
  • Basler Electric 9-0723-00-130 / 9072300130
  • Basler Electric BE1-79MA10A6JC0L0F / BE179MA10A6JC0L0F
  • Basler Electric CBS-377 CURRENT BOOST SYSTEM PART NO 91096001
  • Basler Electric SR4A1B05A3A Static Voltage Regulator 480v-ac 62.5v-dc 10va
  • Basler Electric BE159N A7ED1JC0S0F Solid State BE159N-0 Protective Relay
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K2EW6MB1N0F
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50 Style G4EA1RG0N0F
  • Basler Electric BE1A-25-M1G-A6T-N4V1F Sync-Check Relay
  • Basler Electric SR8A2B10B1A STATIC VOLTAGE REGULATOR
  • BASLER TIME OVERCURRENT RELAY BE1-51A SOLID STATE 1 PH
  • Basler Electric SSR 125-12 STATIC VOLTAGE REGULATOR 9185900102
  • Westinghouse 2374A07G03 Power Supply Basler Electric 90-73900-102
  • 9400200117 - Basler Electric - CONTROL POWER UNIT - 12/24VDC 20WATT
  • Basler Electric Static Voltage Regulator SR32A2B05B3E
  • Basler Electric SR8A2B06B3A Static Voltage Regulator / SR8A2BO6B3A
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY B1EZIPB1N0F
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50-51B-219
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EW6MB0N0F
  • Basler Electric SBO226 Excitation Support System
  • Basler Electric SBO225 Excitation Support System
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EZ1PA0N0F
  • Basler Electric MOC3502 | 90-72300-116 MOTOR POTENTIOMETER
  • Woodward 1751-6058 4 Channel MPU Transformer Module
  • Basler Electric 2D80367G23 DXCB De-Excitation Module 1200V 5000A Excite
  • Basler Electric SSR 63-12-9185900101 Static Voltage Regulator
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EW5MB0N0F
  • Basler Electric MODEL SSR 125-12NF STATIC VOLTAGE REGULATOR 9 1859 00 106
  • Basler Electric Breaker Protection Relay BE1-BPR 9272000315
  • Basler Electric SBO224 Excitation Support System
  • Basler Electric SSR 63-12 Static Voltage Regulator 9 1859 00 101 46534AB
  • Basler Electric AEM-2020 ANALOG EXPANSION MODULE
  • Basler Electric BE 25231-001 Transformer BE25231001
  • Basler Electric PSS-100-Y5 Power Sys Stabilizer dampening oscillations 0.1-5.0Hz
  • Basler Electric BE1-87G-S1A-A1C-A0N0 Variable Percentage Differential Relay
  • Basler Electric SR8A-2B06B3E Static Voltage Regulator SR8A2B06B3E
  • Basler Electric SOLID STATE FREQUENCY CONTROLLER SCP-210 /SCP210 P/No:9095400100
  • Basler Electric BE1-59-A3E-A1J-N1N3F / BE159A3EA1JN1N3F Over Voltage Relay
  • Basler Electric SBO223 Excitation Support System
  • Basler Electric P/N 9 2011 11 100 BRACKET MOUNTED TERMINAL UNIT
  • Basler Electric P/N 9 2011 11 100 BRACKET MOUNTED TERMINAL UNIT
  • Basler Electric voltage regulator P/n: 9 1606 00 101
  • Basler Electric Current Boost System | Model No. CBS-377 P/N 9109600102
  • Basler Electric 8650C72 Exciter Control Module Pcb Board Rev 5
  • Basler Electric 9252000258 Be1-50/51b Overcurrent Relay
  • Basler Electric SR8A-2B01B3A Static Voltage Regulator SR8A2B01B3A
  • Basler Electric SR4A-2B01B3E Static Voltage Regulator SR4A2B01B3E
  • Basler Electric 9017709102 PC Board
  • Basler Electric 9066800102 Excitation Support Systems 9066800-102
  • Beckhoff ELX3152-0090 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELX3158 | EtherCAT Terminal, 8-channel analog input, current, 4…20 mA
  • Beckhoff ELX3152 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3704-1001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0020 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3702-0101 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3702-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3604-0002 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3604-0000 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0032 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0030 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0002 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0000 | EtherCAT Terminal, 2-channel analog input
  • Beckhoff ELM3544-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3542-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • ENOTEC GAS ANALYZER SYSTEM OXITEC 5000 SME-53310000
  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch