Introduction

The IOR810 is a gateway module that connects Symphony Plus SD-Series and HR-Series controllers to the S800 I/O.

As part of a Symphony Plus or Symphony Harmony control system.

The IOR810 provides an alternative way to use the S800 I/O with Sequence of Events (SOE) functionality.

The accuracy of the SOE timestamps is determined by the specifications of each S800 SOE digital input module type.

The IOR810 is the interface between the HN800 I/O bus (electrical or fibre optic) and the existing S800 I/O module bus (fibre optic only).

The core function of the IOR810 is to scan the S800 I/O modules and provide information to the Symphony Plus controller via the HN800.

The IOR810 connects and scans up to seven S800 cluster modems over the fibre module bus.

Each cluster modem can support up to 12 S800 I/O modules.

The distance between the IOR810 and the Symphony Plus controller is up to 30 metres if connected via the electrical HN800 bus;

If connected via a fibre optic HN800 bus, the distance between the IOR810 and the Symphony Plus controller is up to 3000m using RFO810 repeaters.

If using plastic fibre optic cables, the maximum distance of the fibre optic modular bus between the IOR810 and the S800 cluster modem or between two cluster modems in a daisy chain is 15 metres;

If HCS fibre optic cable is used, the maximum distance is 200 metres;

1000 m if using TB825 optical media converters and glass fibre cables.

The cluster modems can be non-redundant or redundant.

The IOR810 receives configuration information from the Symphony Plus controller using standard Symphony Plus function codes to specify S800 I/O data.

It will process inputs and outputs, analogue and digital signal types, pulse counters and Sequence of Events (SOE) data acquisition.

The IOR810 has the following features:

- Selectable redundant or non-redundant configurations

- Supports the Sequence of Events (SOE) function of the S800 I/O subsystem.

- Ability to interface with the following types of I/O in the S800 I/O subsystem: basic AI/AO, basic DI (contact input), SOE DI, basic DO,

Pulse inputs, temperature device inputs (RTDs and thermocouples), intrinsically safe, and redundant I/O Table 5 lists the S800 I/O modules that have been validated for use with the IOR810.

Category Standard Description

Safety CSA C22.2 No. 142 Safety Standard for Process Control Equipment

ANSI/ISA S82.01-1994

EN 61010-1 Safety Standard for Process Control Equipment

Environment EN 60068-2-1. EN 60068-2-2. EN 60068-2-14 Operating temperature

EN 60068-2-78 Operating relative humidity

MIL-STD-810G 501.5. 502.5 Storage/transport temperature

ISA S71.04 (Class 1 liquids, solids, gases) Air Quality

Vibration EN 60068-2-6 Operating vibration (sine wave)

MIL-STD-810G 514.6 Storage/transport vibration

Class 1. basic transport

EN 60068-2-27 Shock

EMI, RFI and surge EN 61000-4-2 (Class 3) ESD

EN 61000-4-3 (Class 3) EMI Susceptibility

EN 61000-4-4 (Class 3) Fast Transient Electrical

EN61000-4-5 (Class 3) Electrical Surge

EN61000-4-6 (Class 3) Conducted immunity

EN 61000-4-8 (Class 3) Magnetic fields

CISPR-16 Radiated emissions

Flammability CSA C22.2 No. 2 (3 levels)

Atmosphere ISA S12.12 Non-flammable equipment

FM Class 3611 Division 2 Equipment

Flammability of Product Components IEEE 383 Inter-Cabinet Cables

UL Class VW-1 Inter-cabinet cables

UL 94 V-0. V-1. V-2 or V5 Flammability of plastic materials

Certification CE Marking EMC Directive 2004/108/EC

(pending) Low Voltage Directive 2006/95/EC

CSA certified for use as process control equipment in general (non-hazardous) locations.

cCSAus certified for use as process control equipment in general (non-hazardous) locations

cCSAus certified for use in Class I; Division 2;

Groups A, B, C, and D: Hazardous Locations.

CSA certified to Canadian and U.S. standards:

CAN/CSA C22.2 No. 1010.1-92 (R1999)

CAN/CSA C22.2 No. 1010.1-92 (R1999)

TIL No. I-29B

CAN/CSA C22.2 No. 1010.1-92 (R1999)

ansi/isa s82.02.01-1994

FM Class Number 3611: October 1999

Must be powered by an approved SELV

must be powered by an approved SELV power supply in accordance with CSA C22.2.

No. 1010.1. Annex H, powered by an approved SELV power supply and mounted in an enclosure specified in ABB documentation.

  • GE Multilin 750-P5-G5-S5-HI-A20-G 750 Management Relay
  • GE Multilin 750-P5-G5-D5-HI-A20-R 750/760 Feeder Mgmt Relay Series
  • GE Multilin 750-P5-G5-D5-HI-A20-G Management Relay
  • GE Multilin 750-P5-G1-D5-HI-A20-R Multilin 1A Zero Sequence Current Inputs
  • GE Multilin 750-P1-G1-S1-HI-A20-R-T-H Feeder Management Relays
  • GE Multilin 750-P1-G1-S1-HI-A20-R Feeder Management Relays
  • GE Multilin 750-P1-G1-D1-HI-A20-R Base Unit 750 Relay
  • GE Multilin 239-RTD-AN-H motor protection relay
  • GE Multilin 489-P5-HI-A20-T-H Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-T Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-E-H Relay Motor Management
  • GE Multilin 489-P1-LO-A20 489 Motor Management Relay Base Unit
  • GE Multilin SR469-P5-LO-A20-T Motor Management Relay
  • GE Relay from GE Grid Solutions SR469-P5-LO-A20-E
  • GE Multilin SR469-P5-LO-A20 Motor Management Relay with Case
  • GE Multilin SR469-P5-HI-A20-T 469 Series Relay
  • GE Multilin SR469-P1-HI-A1-E-H 469 Series Relay
  • GE Multilin SR469-P1-H1-A1-E 469 Series Relay
  • GE Multilin 469-P5-LO-A20-T Phase Current Input 5 A Phase CT Secondaries
  • GE Multilin 469-P5-LO-A20-E LO Control Power with 4-20mA Analog Outputs
  • GE Multilin 469-P5-LO-A20 Motor Management Relay
  • GE Multilin 469-P5-HI-A20-E-H Motor Management Relay
  • GE Multilin 469-P5-HI-A20 469 Motor Management Relay
  • GE Multilin 469-P1-HI-A1-E-H 469 Base Unit Motor Management Relay
  • GE Multilin 469-P1-H1-A1-E 469 Motor Mgmt Relay
  • Beckhoff ED2504 | EtherCAT Terminal, 4-channel PWM output
  • Beckhoff EL2262 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2258 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff EL2252 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A, timestamp
  • Beckhoff EL2212 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2202-0100 | EtherCAT Terminal, 2-channel digital output
  • Beckhoff EL2202 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A, push-pull, tristate
  • Beckhoff EL2124 | EtherCAT Terminal, 4-channel digital output, 5 V DC, 20 mA
  • Beckhoff EL2088 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, ground switching
  • Beckhoff EL2084 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, ground switching
  • Beckhoff EL2068 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, with channel diagnostics
  • Beckhoff EL2044 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with extended diagnostics
  • Beckhoff EL2042 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 x 4 A/1 x 8 A
  • Beckhoff ED2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, push-in, with channel diagnostics
  • Beckhoff EL2034 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A, with diagnostics
  • Beckhoff ED2032 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, push-in, with channel diagnostics
  • Beckhoff EL2032 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A, with diagnostics
  • Beckhoff EL2024-0010 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2024 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2022 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2014 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A, with extended diagnostics
  • Beckhoff ELX2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 30 mA, Ex i
  • Beckhoff ED2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A, push-in
  • Beckhoff EL2008 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 0.5 A
  • Beckhoff EL2004 | EtherCAT Terminal, 4-channel digital output, 24 V DC, 0.5 A
  • Beckhoff ELX2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 45 mA, Ex i
  • Beckhoff EL2002 | EtherCAT Terminal, 2-channel digital output, 24 V DC, 0.5 A
  • TMEIC TM21-TG Series 2-Pole Generator
  • TMEIC TM21-TG Series 4-Pole Generator for Turbine Drive
  • TMEIC Air-Cooled Type Synchronous Generators
  • TMEIC TMdrive-XL85 Medium Voltage AC Drives
  • TMEIC TMdrive-30 Medium Voltage AC Drives
  • TMEIC TMdrive-MVG2 Medium Voltage AC Drives
  • TMEIC TMdrive-70 Medium Voltage AC Drives
  • TMEIC TMdrive-50 Medium Voltage AC Drives
  • TMEIC TMdrive-MVe2 Medium Voltage AC Drives
  • TMEIC TMdrive-XL80 Medium Voltage AC Drives
  • TMEIC TMdrive-XL75 Medium Voltage AC Drives
  • TMEIC TMdrive-XL55 Medium Voltage AC Drives
  • TMEIC TMdrive-70e2 Medium Voltage AC Drives
  • TMEIC TMdrive-Guardian Medium Voltage AC Drives
  • TMEIC TMdrive®-10e2 DP DC Drives
  • TMEIC TMdrive-DCe2 DC Drives
  • TMEIC Dynamic VAR Compensation – Dyna-VAR™
  • TMEIC PV Inverters SOLAR WARE 2500
  • TMEIC PV Inverters SOLAR WARE 2700
  • TMEIC PV Inverters SOLAR WARE 3200
  • TMEIC Power Plant Controller
  • TMEIC High-voltage motors 21-L series
  • TMEIC MV Motor & Drive Solutions for Power Generation
  • TMEIC AC Motors Rolling Mills
  • TMEIC TMdrive®-70 Medium Voltage 3-Level IEGT System Drive
  • TMEIC TMdrive®-70e2 Medium Voltage 3-Level IEGT System Drive
  • TMEIC TMdrive-MVe2 Reactive Power Control
  • TMEIC TMdrive®-30 Medium Voltage 3-Level IGBT System Drive
  • TMEIC Unified Controller nv Series
  • DEIF MVR-F215 Product description
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF PPM 300 Protection & power management
  • DEIF RMC-142D Current relay
  • DEIF GPU-3 hydro Generator protection unit
  • DEIF MVR-200 series Medium Voltage Relay
  • DEIF RMC-131D Current relay
  • DEIF MDR-2 Multi-differential relay
  • DEIF AGC 150 ATS: Advanced Generator Transfer Switch for Seamless Power Management
  • DEIF DVC 350 Digital automatic voltage regulator (AVR)
  • DEIF Digital Voltage Controller DVC 550
  • DEIF TAS-331DG AC transducer for active or reactive power
  • DEIF RMV-112D Undervoltage and overvoltage relay
  • DEIF DPS-1 DC Power Supply
  • DEIF DM 400 hydro Integrated systems
  • DEIF DBC-1 Battery charger
  • DEIF CSQ-3 Multi-function synchroscope
  • DEIF CODESYS Features Software - AWC 500 development package
  • DEIF AMC 300 Advanced Programmable Controller
  • DEIF AGI 400 Advanced graphical interface
  • DEIF BRW-2 & BW Analogue illuminated bridge wing indicators
  • DEIF AWC 500 - G59/3 Integrated G59/3 protection turbine controller unit
  • DEIF AWC 500 Advanced Controller
  • DEIF ASK & ASR Measuring transformer
  • DEIF ASC-4 Battery Automatic Sustainable Controller
  • DEIF ASC plant management Automatic sustainable controller
  • DEIF AOP Additional operator panel
  • DEIF AMC 600 Programmable automation controller with EtherCAT based I/O
  • DEIF AL8-2 Alarm panel
  • DEIF AGC 150 Hybrid Advanced Genset Controller
  • DEIF AGC 150 PMS Lite Simple power management controller
  • DEIF AGC 150 Generator Advanced Genset Controller
  • DEIF AGC 150 Remote Display Remote access and control unit
  • DEIF MVR-250 series Medium Voltage Relay
  • DEIF MVR-210 series Medium Voltage Relay
  • DEIF The SGC series
  • DEIF iE 350 Marine Highly flexible and cybersecure intelligent energy controller
  • DEIF iE 250 Marine Versatile and cybersecure intelligent energy controller for maritime applications
  • DEIF iE 150 Marine Simple and effective power management
  • DEIF iE 650 PLC Extreme robust Programmable Automation controller with EtherCAT based I/O
  • DEIF iE 350 PLC Robust right out of the box
  • DEIF iE 250 PLC Versatile and modular intelligent energy PLC controller
  • DEIF XL / BW / BRW-2 Illuminated indicators
  • DEIF SGC 120/121 Single Genset Controllers
  • DEIF Load Sharing Unit LSU-112DG
  • DEIF Automatic Genset Controller AGC-4