Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

How does the A-B Communication Module communicate with serial devices?

From:A-B | author:Mr.Chen | Time :2024-07-22 | 200 view: | Share:

SCANport Data Link

A data link is a pointer used by some SCANport devices to transmit information to a drive.

The data link allows parameter values to be written when sending logical commands and references to the drive. The data link also allows parameter values to be read when reading logic status and feedback.

SCANport devices that support this feature have a set of parameters for data link configuration.

These are called the ‘data link input’ and ‘data link output’ parameters.

The Datalink feature is enabled by setting the correct switch on the communication module SW3 to ‘Enable’ and configuring the ‘Datalink Input’ and ‘Datalink Output’ parameters in the SCANport device.

Each datalink consists of two 16-bit input words and two 16-bit output words.

By setting the two ‘Datalink In’ (data link input) and ‘Datalink Out’ (data link output) parameters in the SCANport device

Set the two ‘Datalink In’ parameters for this data link to the desired target parameters.

Similarly, by setting the two ‘Datalink Out’ parameters, each of the two output words can be configured to Similarly, the

Each of the two output words can be configured by setting the two ‘Data Link Output’ parameters for that Datalink.

Each Datalink switch on SW3 enables or disables one Datalink.

If a Datalink is enabled, the parameter values set in the ‘Data Link Output’ parameter will be transmitted to the communication module.

The parameter values set in the parameter will be transmitted to the communications module, and the data sent by the communications module for that datalink will be transferred to the parameters set in the ‘Data Link Output’ parameter.

If the data link is enabled, the parameter values set in the ‘Datalink Out’ parameter will be transferred to the communication module.

and the data sent by the communication module for the data link will be transmitted to the ‘Datalink In’ parameter.

If the data link is not enabled If the data link is not enabled, the data transmitted to the SCANport device for this data link will be zero.

The data transmitted to the SCANport device will be zero and the communication module will ignore any data sent by the SCANport device.

The communication module will ignore any data sent by the SCANport device.

If the ‘Data Link Input’ parameter is not configured for an input word, that input word will be ignored.

If the ‘Datalink Out’ parameter is not configured for the output word, the output word will be undefined. The output word will be undefined (usually set to zero).

The datasheet has up to eight areas, each with a different purpose.

1. parameter value read or write. Reading data from a file in this area will cause the communications module to read parameter values from the SCANport device, to

and send these values as a response to the read message. Writing data to a file in this area will cause the communications module to write data to the SCANport device's parameters.

Parameter.

2. the status of the last time the parameter was written. This area is read-only. When read, the data returned will contain information about the status of the last parameter write performed by the communications module.

If no errors occurred during the write, all data returned will be zero. The area is read from element number 0.

3. Parameter Read Full. This area is read-only. When read, the returned data contains 20 words (40 bytes) of information for each parameter, including the scaling, parameter text, and parameter name.

The data returned when read contains 20 words (40 bytes) of information for each parameter, including scale, parameter text, unit text, minimum value, maximum value, and default value. When reading this area, set the number of elements to 20 times the number of parameters to be read. 4.

4. block transfer simulation area. This area provides a method of sending and receiving SCANport information to and from the SCANport device.

This allows the user to execute all SCANport commands supported by the device.

The structure of this data table is the same as the block transfer data table for the 1203-GD1. GK1. and GM1 RIO communication modules.

To send a SCANport message, write data to this area starting with element number 0. Allow the SCANport device enough time to respond to the message and then read the data.

  • A-B Kinetix 5700 Accessory Module Specifications 2198-CAPMOD-DCBUS-IO
  • A-B Kinetix 5700 Accessory Module Specifications 2198-DCBUSCOND-RP312
  • A-B Kinetix 5700 Accessory Module Specifications 2198-CAPMOD-2240
  • A-B Kinetix 5700 Servo Drive Specifications 2198-S160-ERSx
  • A-B Kinetix 5700 Servo Drive Specifications 2198-S130-ERSx
  • A-B Kinetix 5700 Servo Drive Specifications 2198-S086-ERSx
  • A-B Kinetix 5700 Servo Drive Specifications 2198-D057-ERSx
  • A-B Kinetix 5700 Servo Drive Specifications 2198-D032-ERSx
  • A-B Kinetix 5700 Servo Drive Specifications 2198-D020-ERSx
  • A-B Kinetix 5700 Servo Drive Specifications 2198-D012-ERSx
  • A-B Kinetix 5700 Servo Drive Specifications 2198-D006-ERSx
  • A-B Kinetix 5700 Power Supply Specifications 2198-RP312
  • A-B Kinetix 5700 Power Supply Specifications 2198-RP263
  • A-B Kinetix 5700 Power Supply Specifications 2198-RP200
  • A-B Kinetix 5700 Power Supply Specifications 2198-RP088
  • A-B Kinetix 5700 Power Supply Specifications 2198-P208
  • A-B Kinetix 5700 Power Supply Specifications 2198-P141
  • A-B Kinetix 5700 Power Supply Specifications 2198-P070
  • A-B Kinetix 5700 Power Supply Specifications 2198-P031
  • Emerson AWV7005HC20000 AMS Device ManagerField Communicator Interface Kit
  • Emerson AWV7005HC00025 AMS Device ManagerField Communicator Interface Kit (25 tags)
  • Emerson 00475-0142-2003 EasyUpgrade(New/Renew) License via Web
  • Emerson 00375-0142-0002 FounoAnow Fieldbus License Via Web
  • Emerson 00475-0049-DVD1 Resource DVD
  • Emerson 00475-0045-3001 Getting Started Guide
  • Emerson 00475-0019-SK02 Shop Accessory kit
  • Emerson 00475-0019-5K01 Shop Accessory kit
  • Emerson 00475-0019-FK01 Field Accessory Kit
  • Emerson 00475-0044-0001 Stand
  • Emerson 00475-0018-0023 Bluetooth AdaptertKa
  • Emerson 00375-0018-0022 System Card (5D) Reader
  • Emerson 00375-0015-0002 IrDA to USBAdapteri
  • Emerson 00475-0006-0001 Stylus (pack of 2)
  • Emerson 00475-0005-0005 Protective Rubber Boot with Stand
  • Emerson TREX-0005-0004 Magnetic Hanger
  • Emerson 00475-0005-0003 carrying Case
  • Emerson 00475-0005-0002 Hand Strap
  • Emerson TREX-0004-0001 Lead Set with connectors
  • Emerson 00375-0003-0003 Australian (AU) cord for Power Supply/Charger
  • Emerson 00375-0003-0002 Power Supply/Charger Standard Cord Set
  • Emerson 00475-0003-0022 Power Supply& Charger
  • Emerson 00475-0002-0022 Rechargeable Lithium-lon Power Module
  • Emerson 00275-0096-0001 Ruggedized 250 0hm Load Resistor
  • Emerson TREX-SUPR-1201 Premium Support
  • Emerson TREX-SUST-1201 Standard Support
  • Emerson TREX-APRM-PEO1 Radar Master App TREX-APRM-PE01
  • Emerson TREX-APWP-PEO1 WirelessHART Provisioning App
  • Emerson TREX-ABFF-PEO1 FOUNDATION Fieldbus license bundle
  • Emerson TREX-ABFF-0301 FOUNDATION Fieldbus license bundle - 90 Day Demo
  • Emerson TREX-0045-0001 Device Communicator Plus communication module
  • Emerson TREX-0012-0011 Stand (replacementintegral to communication module)
  • Emerson TREX-PMDP-1211 Device Communicator Plus communication module
  • Emerson TREX-PMDC1211 Device Communicatorcommunication modulel
  • Emerson TREX-0096-0001 Ruggedized 250 0hm Load Resistorzl
  • Emerson TREX-0004-0002 USB cable (UsB to micro UsB)
  • Emerson TREX-0005-0004 Magnetic Hanger
  • Emerson TREX-0005-0009 Shoulder Strap(replacement for use with carrying case)
  • Emerson TREX-0005-0011 Carrying Case (includes hand & shoulder straps)
  • Emerson TREX-0005-0002 Hand Strap (replacement set of 2)
  • Emerson TREX-0004-0001 Lead Set with connectors
  • Emerson TREX-FFPA-0001 FOUNDATlON Fieldbus Power Plug
  • Emerson TREX-0003-0004 AC Outlet Plugs
  • Emerson TREX-0003-0002 AC Outlet Plugs
  • Emerson TREX-0003-0022 DCAdapter(12vvehicle accessory outlet)
  • Emerson TREX-0003-0012 AC Adapter (includes Us, EU, UK, AU outlet plugs)
  • Emerson TREX-0002-1211 Rechargeable Li-lon Power Module
  • Emerson IC760COW15CDA 15"PACSystemsRXiHMlEmersonBezel,OutdoorSLRWidescreen
  • Emerson 1C760COW12CDA 12"PACSystemsRXiHMlEmersonBezel,OutdoorSLRWidescreen
  • Emerson 1C760C5W24CDA 24"PACSystemsRXiHMlEmersonBezel,Widescreen
  • Emerson 1C760C5W19CDA 19"PACSystemsRXiHMlEmersonBezel,Widescreen
  • Emerson IC760CSW15CDA 15"PACSystemsRXiHMlEmersonBezel,Widescreen
  • Emerson 1C760CSW12CDA 12"PACSystemsRXiHMlEmersonBezel,Widescreen
  • Emerson R2L0N2A3CD PACSystems RXi2-LP w/ PACEdge & Movicon Connext
  • Emerson R2L0N1A3AD PACSystems RXi2-LP w/ PACEdge & Movicon Connext
  • Emerson R2L0N2A2CD RXi2-LP w/ PACEdge
  • Emerson R2L0N1A2AD RXi2-LP w/ PACEdge
  • Emerson R2L0N2B0C PACSystems RXi2-LP IPC
  • Emerson R2L0N2B1C PACSystems RXi2-LP IPC
  • Emerson R2L0N1B0C PACSystems RXi2-LP IPC
  • Emerson R2L0N1B1C PACSystems RXi2-LP IPC
  • Emerson R2L0N2A0C PACSystems RXi2-LP IPC
  • Emerson R2L0N2A1C PACSystems RXi2-LP IPC
  • Emerson R2L0N1A0A PACSystems RXi2-LP IPC
  • Emerson R2L0N1A1A PACSystems RXi2-LP IPC
  • Emerson R2U2N1D3B1T1F RXi2-UP Industrial PC
  • Emerson R2U2N1F1A2T0A RXi2-UP IPC, Quad Core XEON E3-1505Lv6
  • Emerson R2U2N1J1B2T0A RXi2-UP IPC, Quad Core XEON E3-1505Lv6
  • Emerson R2U1N1C1A1T0A RXi2-UP IPC, Quad Core XEON E3-1505Lv6
  • Emerson R2U1N1C0A1T0A RXi2-UP IPC, Quad Core XEON E3-1505Lv6
  • Emerson R2U1N1F1A1T0A RXi2-UP IPC, Quad Core i7-7820EQ
  • Emerson R2U1N1J1B1T0A RXi2-UP IPC, Quad Core XEON E3-1501M
  • Emerson R2U1N1E1A1T0A RXi2-UP IPC, Quad Core i5-7442EQ
  • Emerson R2U1N1E0A1T0A RXi2-UP IPC, Quad Core i5-7442EQ
  • Emerson R2U1N1B1A1T0A RXi2-UP IPC, Dual Core i3-7102E
  • Emerson R2U1N1B0A1T0A RXi2-UP IPC, Dual Core i3-7102E
  • Emerson R2U0N1J1B1T0A RXi2-UP IPC, Quad Core XEON E3-1501M
  • Emerson R2U0N1J0B1T0A RXi2-UP IPC, Quad Core XEON E3-1501M
  • Emerson R2U0N1E1A1T0A RXi2-UP IPC, Quad Core i5-7442EQ
  • Emerson R2U0N1E0A1T0A RXi2-UP IPC, Quad Core i5-7442EQ
  • Emerson R2U0N1B1A1T0A RXi2-UP IPC, Dual Core i3-7102E
  • Emerson R2U0N1B0A1T0A RXi2-UP IPC, Dual Core i3-7102E
  • Emerson R2B1NTWIN3A0A RXi2-BP w/ PACEdge & Movicon Connext
  • Emerson R2B0N1WIN3A0A RXi2-BP w/ PACEdge & Movicon Connext
  • Emerson R2B1N1C1N3A0A RXi2-BP w/ PACEdge & Movicon Connext
  • Emerson R2B0N1C1N3A0A RXi2-BP w/ PACEdge & Movicon Connext
  • Emerson R2B0N9C4N3A0A RXi2-BP w/ PACEdge & Movicon Connext
  • Emerson R2B1N1E1N3A0A RXi2-BP w/ PACEdge
  • Emerson R2B0N9E4N3A0A RXi2-BP w/ PACEdge
  • Emerson R2B0N1E1N3A0A RXi2-BP w/ PACEdge
  • Emerson R2B0N2P2N3A0A RXi2-BP Industrial PC
  • Emerson R2BIN2P2N3A0A RXi2-BP Industrial PC
  • Emerson R2B0N4F1N3A0F RXi2-BP Industrial PC
  • Emerson R2B1N4F1N3A0F RXi2-BP Industrial PC
  • Emerson R2B0NAMIN3A0A RXi2-BP Industrial PC
  • Emerson R2BINAMIN3A0A RXi2-BP Industrial PC
  • Emerson R2B00ACCMP02 RXi2-BP Industrial PC
  • Emerson R2B00ACCMP01 RXi2-BP Industrial PC
  • Emerson R2B00ACCRMM01 RXi2-BP Industrial PC
  • Emerson R2B1N5A3N3A0A RXi2-BP Industrial PC
  • Emerson R2B0N5A3N3A0F RXi2-BP Industrial PC
  • Emerson R2BIN5N3N3A0A RXi2-BP Industrial PC
  • Emerson R2B0N4A3N3A0F RXi2-BP Industrial PC
  • Emerson R2B1N4N3N3A0F RXi2-BP Industrial PC
  • Emerson R2B0N4N3N3A0F RXi2-BP Industrial PC
  • Emerson R2BIN4A2N3A0F RXi2-BP Industrial PC
  • Emerson R2B0N4A2N3A0F RXi2-BP Industrial PC
  • Emerson R2BIN4N2N3A0F RXi2-BP Industrial PC
  • Emerson R2B0N4N2N3A0F RXi2-BP Industrial PC