Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

How does the A-B Communication Module communicate with serial devices?

From:A-B | author:Mr.Chen | Time :2024-07-22 | 842 view: | 🔊 Click to read aloud ❚❚ | Share:

SCANport Data Link

A data link is a pointer used by some SCANport devices to transmit information to a drive.

The data link allows parameter values to be written when sending logical commands and references to the drive. The data link also allows parameter values to be read when reading logic status and feedback.

SCANport devices that support this feature have a set of parameters for data link configuration.

These are called the ‘data link input’ and ‘data link output’ parameters.

The Datalink feature is enabled by setting the correct switch on the communication module SW3 to ‘Enable’ and configuring the ‘Datalink Input’ and ‘Datalink Output’ parameters in the SCANport device.

Each datalink consists of two 16-bit input words and two 16-bit output words.

By setting the two ‘Datalink In’ (data link input) and ‘Datalink Out’ (data link output) parameters in the SCANport device

Set the two ‘Datalink In’ parameters for this data link to the desired target parameters.

Similarly, by setting the two ‘Datalink Out’ parameters, each of the two output words can be configured to Similarly, the

Each of the two output words can be configured by setting the two ‘Data Link Output’ parameters for that Datalink.

Each Datalink switch on SW3 enables or disables one Datalink.

If a Datalink is enabled, the parameter values set in the ‘Data Link Output’ parameter will be transmitted to the communication module.

The parameter values set in the parameter will be transmitted to the communications module, and the data sent by the communications module for that datalink will be transferred to the parameters set in the ‘Data Link Output’ parameter.

If the data link is enabled, the parameter values set in the ‘Datalink Out’ parameter will be transferred to the communication module.

and the data sent by the communication module for the data link will be transmitted to the ‘Datalink In’ parameter.

If the data link is not enabled If the data link is not enabled, the data transmitted to the SCANport device for this data link will be zero.

The data transmitted to the SCANport device will be zero and the communication module will ignore any data sent by the SCANport device.

The communication module will ignore any data sent by the SCANport device.

If the ‘Data Link Input’ parameter is not configured for an input word, that input word will be ignored.

If the ‘Datalink Out’ parameter is not configured for the output word, the output word will be undefined. The output word will be undefined (usually set to zero).

The datasheet has up to eight areas, each with a different purpose.

1. parameter value read or write. Reading data from a file in this area will cause the communications module to read parameter values from the SCANport device, to

and send these values as a response to the read message. Writing data to a file in this area will cause the communications module to write data to the SCANport device's parameters.

Parameter.

2. the status of the last time the parameter was written. This area is read-only. When read, the data returned will contain information about the status of the last parameter write performed by the communications module.

If no errors occurred during the write, all data returned will be zero. The area is read from element number 0.

3. Parameter Read Full. This area is read-only. When read, the returned data contains 20 words (40 bytes) of information for each parameter, including the scaling, parameter text, and parameter name.

The data returned when read contains 20 words (40 bytes) of information for each parameter, including scale, parameter text, unit text, minimum value, maximum value, and default value. When reading this area, set the number of elements to 20 times the number of parameters to be read. 4.

4. block transfer simulation area. This area provides a method of sending and receiving SCANport information to and from the SCANport device.

This allows the user to execute all SCANport commands supported by the device.

The structure of this data table is the same as the block transfer data table for the 1203-GD1. GK1. and GM1 RIO communication modules.

To send a SCANport message, write data to this area starting with element number 0. Allow the SCANport device enough time to respond to the message and then read the data.

  • Beckhoff EL2872-0010 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff EL2872 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff EL2869 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff ED2838 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff EL2838 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff ED2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2828 | EtherCAT Terminal, 8-channel digital output, 24 V DC, 2 A
  • Beckhoff EL2819 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff ED2807 | EtherCAT Terminal, 32-channel digital output, 24 V DC, 0.5 A, push-in
  • Beckhoff EL2407 | EtherCAT Terminal, 32-channel digital output, 24 V DC, 0.5 A
  • Beckhoff EL2409 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff ED2809 | EtherCAT Terminal, 16-channel digital output
  • Beckhoff EL2809 | EtherCAT Terminal, 16-channel digital output, 24 V DC, 0.5 A
  • Beckhoff EL2808 | EtherCAT Terminal, 8-channel digital output
  • Beckhoff EL2798 | EtherCAT Terminal, 8-channel solid state relay output
  • Beckhoff EL2794 | EtherCAT Terminal, 4-channel solid state relay output
  • Beckhoff EL2788 | EtherCAT Terminal, 8-channel solid state relay output
  • Beckhoff EL2788 | EtherCAT Terminal, 8-channel solid state relay output
  • Beckhoff EL2788 | EtherCAT Terminal, 8-channel solid state relay output
  • Beckhoff EL2784 | EtherCAT Terminal, 4-channel solid state relay output
  • Beckhoff EL2722 | EtherCAT Terminal, 2-channel triac output
  • Beckhoff EL2712 | EtherCAT Terminal, 2-channel triac output
  • Beckhoff ELX2792 | EtherCAT Terminal, 2-channel solid state relay output
  • Beckhoff EL2652 | EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2642 | EtherCAT Terminal, 2-channel reed output
  • Beckhoff EL2634 | EtherCAT Terminal, 4-channel relay output
  • Beckhoff EL2624 | EtherCAT Terminal, 4-channel relay output
  • Basler Electric BE1-51 G1EZ1PA1N0FY Time Overcurrent Relay
  • Basler Electric Under-Voltage Relay BE1-27 A3EA1JN1N4F
  • Basler Electric BE1-27/59 Under/Over Voltage Relay A3F C4Y A0N2F
  • Basler Electric BE1-27/59A3FC4JB4B0F Voltage Relay
  • Basler BE1-27 A3EA1JA0S5F Under Voltage Relay
  • Basler Electric BE1-27 A3E C3J A1N6F Solid State Protective Relay
  • Basler Electric BE1-27/59 A3F E1L NON1F OVERVOLTAGE RELAY T245577
  • Basler Electric BE1-27A2EE1JA0A2F Voltage Relay
  • Basler Electric BE1-27 A3EE1JA1N6F Voltage Relay
  • Basler Electric L304KC / L304KC Camera Interface
  • Basler Electric BE3-25AX / BE325AX Synchronizing Check Relays
  • Basler Electric BE3-25-1D1N4 9319100106 480V Synchronizing Check Relays
  • Basler Electric BE3-25-1A1N4 SYNCH CHECK RELAY 9319100100
  • Basler Electric BE3-25-1C1N4 Synchronizing Check Relays
  • Basler Electric BE3-25-1S1N4 / BE3251S1N4 Synchronizing Check Relays
  • Basler Electric BE1-59N-A8E-E1L-N0S1F / BE159NA8EE1LN0S1F
  • NIB Basler Electric BE1-59N Style A5EE1KC0N0F Rev X Ground Fault Relay
  • Basler Electric BE1-59N A6E E1C B0N1F / BE159NA6EE1CB0N1F
  • Basler Electric BE1-59N GROUND FAULT RELAY T214750
  • Basler Electric BE1-59N-A5E-E1L-N0S1F / BE159NA5EE1LN0S1F
  • Basler Electric BE1-59N-A7E-D1J-D0N0F / BE159NA7ED1JD0N0F
  • Basler Electric BE1-59N A6EE1JC0N1F Ground Fault Overvoltage Relay
  • Basler Electric BE1-851 Overcurrent Relay Mechanism G5B2S0N
  • Basler Electric BE1-851 Overcurrent Relay H5A2S1N
  • Basler Electric DECS 125-15-B2C5 DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric PLA2400-12GM / PLA240012GM
  • Basler Electric BE1-50/51B-235 / BE15051B235 Self-Powered Time Overcurrent Relay
  • Basler Electric BE1-25 M9FA6PN4N0F / BE125M9FA6PN4N0F
  • Basler Electric BE1-27/59 UNDERVOLTAGE T238468
  • Basler Electric BE1-32R POWER RELAY, STYLE: D1EE1PA0N0F
  • Basler Electric BE1-32R ~ BE1-E1P-BON0F Protective Relay
  • Basler Electric BE1-32R POWER RELAY ONAN 0307-2661-09 B2EE1PA0N1F
  • Basler Electric Solid State Protective Relay BE1-32R E1EA1OA0N0F
  • Basler Electric Solid State Protective Relay BE1-32R Style B2ED1PB0N0F
  • Basler Electric Solid State Protective Relay BE1-32R STYLE C3ED1TA0S1F
  • Basler Electric C2EE1PA0N1F BE1-32R NSMP
  • Basler Electric BE1-32R PROTECTIVE RELAY STYLE A1E E1P BOS1P BE132R
  • Basler Electric BE1-32R Power Relay B3E E1R A0N1F
  • Basler Electric BE1-32R Power Solid State Relay, Style E2E A10 A0N0F
  • Basler Electric BE1-32R Power Relay A2E D1R A0N0F
  • Basler Electric Power Relay BE1-32R Style #: D3E E1R A0N1F
  • Basler Electric Power Relay BE1-32R D1E A1P A0N1F
  • Basler Electric BE1-32R Power Relay B2EE1PA0N1F Rev. AD
  • Basler Electric BE1-32R Power Solid State Relay F1F E1K A4N1F
  • Basler Electric BE1-700 Digital Protective Relay
  • Basler Electric BE1-700 E0N2X1N Digital Protective Relay
  • Basler Electric GROUND FAULT OVERVOLTAGE RELAY BE1-59N
  • Basler Electric BE1-851 / 887DB / 9289900180 DIFFERENTIAL RELAY
  • Basler Electric BE10493002 NSMP
  • Basler Electric SR4A2B01B3A / SR4A2B01B3A Static Voltage Regulator
  • Basler Electric BE1-51AK2EW7MB1NOF / BE151AK2EW7MB1NOF
  • Basler Electric EL 200-7 / EL2007 MINIMUM/MAXIMUM EXCITATION LIMITER
  • Basler Electric BE1-25 M9FA6PN4N0F / BE125M9FA6PN4N0F Sync-Check Relay
  • Alfa Laval M3 Gasketed plate heat exchanger
  • Alfa Laval TS35 Gasketed plate heat exchanger
  • Alfa Laval TL35 Gasketed plate heat exchanger
  • Alfa Laval TS20 Gasketed plate heat exchanger
  • Alfa Laval T2 Gasketed plate heat exchanger
  • Alfa Laval T15 Gasketed plate heat exchanger
  • Alfa Laval TL15 Gasketed plate heat exchanger
  • Alfa Laval TS6 Gasketed plate heat exchanger
  • Alfa Laval TL10 Gasketed plate heat exchanger
  • Alfa Laval T45 Gasketed plate heat exchanger
  • Alfa Laval TS50 Gasketed plate heat exchanger
  • Alfa Laval TL6 Gasketed plate heat exchanger
  • Alfa Laval T35 Gasketed plate heat exchanger
  • Alfa Laval T5 Gasketed plate heat exchanger
  • Alfa Laval T50 Gasketed plate heat exchanger
  • Alfa Laval TL3 Gasketed plate heat exchanger
  • Alfa Laval T25 Gasketed plate heat exchanger
  • Alfa Laval T10 Gasketed plate heat exchanger
  • Alfa Laval T6 Gasketed plate heat exchanger
  • Beckwith Electric M-2324C Adapter Panel
  • Beckwith Electric M-2278 Adapter Panel
  • Beckwith Electric M-2326 Adapter Panel
  • Beckwith Electric M-2356B Adapter Panel
  • Beckwith Electric M-2355B Adapter Panel
  • Beckwith Electric M-2347 Adapter Panel
  • Beckwith Electric M-2264B Adapter Panel
  • Beckwith Electric M-2148 Adpapter Panel
  • Beckwith Electric M-2355Q Adapter Panel
  • Beckwith Electric M-5329 Three-Phase LTC Backup Control
  • Beckwith Electric M-0127A and M-0170A AC Current Relays
  • Beckwith Electric M-2293B Adapter Panel
  • Beckwith Electric M-2069 Adapter Panel
  • Basler Electric BEI-79A1AA5CA3M1F / BEI79A1AA5CA3M1F Reclosing Relay
  • Basler Electric Negative Sequence Voltage Relay BE1-47N E3FD1PC2S0F
  • Basler Electric BE1-47NE3EE10A0N0F Negative Sequence Voltage Relay
  • Basler Electric BE1-47N STYLE E3ED1PA0N0F Negative Sequence Voltage Relay
  • Basler Electric Negative Sequence Voltage Relay BE1-47N E3FE1PC3N3F
  • Basler Electric Negative Sequence Voltage Relay BE1-47N STYLE E3FD1PD2N4F
  • Basler Electric Negative Sequence Voltage Relay BE1-47N Style E3FE1PC3T4F
  • Basler Electric Negative Sequence Voltage Relay BE1-47N E3FD1PC2N3F
  • Basler Electric Negative Sequence Voltage Relay BE1-47N E3FA1PC1N3F
  • Basler Electric BE1-47NE3EA1PB0N1F / BE147NE3EA1PB0N1F
  • Basler Electric Solid State Protective Relay BE1-47N Voltage Phase Sequence
  • Basler Electric LEROY SOMER DECS-100 9287500132 DIGITAL EXCITATION CONTROL SYSTE
  • Basler Electric DECS-100-A05 Automatic Voltage Regulator for Engine Generator
  • Basler Electric DECS-100-B11 Automatic Voltage Regulator Automatic Voltage Regulator
  • Basler Electric DECS-100-B01 DIGITAL EXCITATION CONTROLLER
  • Rolls-Royce R02TCN-E0L3-00 Remote controller