From:A-B | author:Mr.Chen | Time :2024-07-22 | 910 view: | 🔊 Click to read aloud ❚❚ | Share:

SCANport Data Link

A data link is a pointer used by some SCANport devices to transmit information to a drive.

The data link allows parameter values to be written when sending logical commands and references to the drive. The data link also allows parameter values to be read when reading logic status and feedback.

SCANport devices that support this feature have a set of parameters for data link configuration.

These are called the ‘data link input’ and ‘data link output’ parameters.

The Datalink feature is enabled by setting the correct switch on the communication module SW3 to ‘Enable’ and configuring the ‘Datalink Input’ and ‘Datalink Output’ parameters in the SCANport device.

Each datalink consists of two 16-bit input words and two 16-bit output words.

By setting the two ‘Datalink In’ (data link input) and ‘Datalink Out’ (data link output) parameters in the SCANport device

Set the two ‘Datalink In’ parameters for this data link to the desired target parameters.

Similarly, by setting the two ‘Datalink Out’ parameters, each of the two output words can be configured to Similarly, the

Each of the two output words can be configured by setting the two ‘Data Link Output’ parameters for that Datalink.

Each Datalink switch on SW3 enables or disables one Datalink.

If a Datalink is enabled, the parameter values set in the ‘Data Link Output’ parameter will be transmitted to the communication module.

The parameter values set in the parameter will be transmitted to the communications module, and the data sent by the communications module for that datalink will be transferred to the parameters set in the ‘Data Link Output’ parameter.

If the data link is enabled, the parameter values set in the ‘Datalink Out’ parameter will be transferred to the communication module.

and the data sent by the communication module for the data link will be transmitted to the ‘Datalink In’ parameter.

If the data link is not enabled If the data link is not enabled, the data transmitted to the SCANport device for this data link will be zero.

The data transmitted to the SCANport device will be zero and the communication module will ignore any data sent by the SCANport device.

The communication module will ignore any data sent by the SCANport device.

If the ‘Data Link Input’ parameter is not configured for an input word, that input word will be ignored.

If the ‘Datalink Out’ parameter is not configured for the output word, the output word will be undefined. The output word will be undefined (usually set to zero).

The datasheet has up to eight areas, each with a different purpose.

1. parameter value read or write. Reading data from a file in this area will cause the communications module to read parameter values from the SCANport device, to

and send these values as a response to the read message. Writing data to a file in this area will cause the communications module to write data to the SCANport device's parameters.

Parameter.

2. the status of the last time the parameter was written. This area is read-only. When read, the data returned will contain information about the status of the last parameter write performed by the communications module.

If no errors occurred during the write, all data returned will be zero. The area is read from element number 0.

3. Parameter Read Full. This area is read-only. When read, the returned data contains 20 words (40 bytes) of information for each parameter, including the scaling, parameter text, and parameter name.

The data returned when read contains 20 words (40 bytes) of information for each parameter, including scale, parameter text, unit text, minimum value, maximum value, and default value. When reading this area, set the number of elements to 20 times the number of parameters to be read. 4.

4. block transfer simulation area. This area provides a method of sending and receiving SCANport information to and from the SCANport device.

This allows the user to execute all SCANport commands supported by the device.

The structure of this data table is the same as the block transfer data table for the 1203-GD1. GK1. and GM1 RIO communication modules.

To send a SCANport message, write data to this area starting with element number 0. Allow the SCANport device enough time to respond to the message and then read the data.

Then read the response message from this area starting with element number 0.

5. producer/consumer emulation area. Each element in this area has a different function.

- Logical Command/Status. Logical commands are sent to the driver when writing.

Reading provides the logical status of the SCANport device.

- Reference/Feedback. Sends a reference to the SCANport device when writing. Read provides feedback from the SCANport device. The meaning of the reference and feedback values depends on the type of SCANport device.

- DataLink A1. a value is sent to the parameter pointed to by the DataIn A1 parameter of the SCANport device when writing to Datalink A1.

Reads from Datalink A1 the value of the parameter pointed to by the DataOut A1 parameter of the SCANport device.

- Datalink A2 to Datalink D2 have the same function as Datalink A1.

6. communication module parameters. All four elements in this area can be read or written to and affect the operation of the communication module as follows:

- ENQ Quantity. The number of ENQs sent before the module gives up on receiving an ACK or NAK. (Default = 3)

- NAK Count. The number of times the module resends the message if the reply is always NAK. (default = 3)

- Message Timeout. The number of milliseconds the module waits before sending an ENQ. (default = 100 milliseconds)

- Application Timeout. The number of seconds the module waits between sending messages before failing the connected SCANport device. (Default value is set by the Configuration DIP switch)

7. reserved for future expansion. If an attempt is made to read or write any address in this area, the communications module will respond with an error message.

8. system area. Reading from this area will cause the communications module to respond with a 22-character string.

This string is set at power-up to a product text string containing the SCANport device with ‘/1203’ appended.

Writing to this field will change the characters contained in the string. After a power failure, the string will revert to the original text.

  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch
  • Eaton 5884-1400 6-Digit Dual Preset Control W/ Batch Control
  • Eaton 1023843 Power Circuit Board 94V
  • EATON ES4P-221-DRXD1 24VDC NSMP
  • Eaton DH222NWK heavy duty fusible safety switch
  • Eaton Touch Panel 10.1 inch XV-303-10-C00-A00-1C
  • Eaton RDF200J-3 Bussmann series RDF fused rotary disconnect switch
  • EATON CORPORATION A200M2CACD A200 NEMA Motor Control
  • Eaton SPD160208Y3J Surge Protection Device
  • EATON CORPORATION SPD160208Y3K SURGE SUPPRESSOR
  • EATON DILM400/22 (RA250) 200KW Coil Voltage/Coil 110-250V 40-60Hz/DC
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • EATON CORPORATION D820MPM HMI
  • EATON PXG900 Power Xpert Insight Gateway 900
  • Eaton Durant 5882-7 Digital Counter loc2D3
  • EATON AXCELIS 1220-0012-0002 DISK VACUUM DI CONTROLLER
  • Eaton 1383B-6501 80 Series Photoelectric Sensor Head
  • Eaton FDC2100L Series C molded case switch
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • Eaton FD3200L circuit breaker
  • Eaton Touch Screen Control Panel X-152-D6-10TVRC-10
  • EATON VICKERS EEA-PAM-523-A-32 02-326001 POWER AMPLIFIER
  • Saacke Seavis HMI 03 EATON XV-102-B6-35TQR-1AL-PLC HMI Touch Panel
  • EATON MTL E05016 DIGITAL INPUT EUROCARD E05516-2134
  • Eaton HFD3150 3P 150A 600VAC Circuit Breaker
  • Eaton HMIVU06CUNB1 HMi Operator Interface, RS-232, 5.6"
  • Cutler-Hammer/ Eaton Panelmate PowerPro 5785 with cables LCD monitor
  • Eaton D100CA40 40 I/O Micro PLC 115VAC Input Triac Output
  • EATON CUTLER HAMMER 66D2032GX1 MP-3000 PROTECTION RELAY
  • EATON R9L3200FJ Rotary Disconnect Switch
  • EATON CORPORATION E51CLT16PCU Switch
  • Aerotech Modular System Control Console
  • Aerotech TV Series Transformers
  • Aerotech TM5 Transformer Module (500 watts)
  • Aerotech TM3 Transformer Module
  • Aerotech UFM Noise Filter Module
  • Aerotech MFM10-2 Motor filter module
  • Aerotech MFM10-1 Motor filter module
  • Aerotech MPG Handwheel Pendant
  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3246-0000 | EtherCAT Terminal, 6-channel analog input, temperature
  • Beckhoff ELM3244-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3148-0000 | EtherCAT Terminal, 8-channel analog input, multi-function
  • Beckhoff ELM3146-0000 | EtherCAT Terminal, 6-channel analog input, multi-function
  • Beckhoff ELM3144-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckwith Electric M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-3919A Graphic Display Unit/ Human Machine Interface
  • Beckwith Electric M-4172 Digital Motor Bus Transfer System
  • Beckwith Electric M-3904B Remote Monitoring Module
  • Beckwith Electric M-3410A Intertie/Generator Protection Relay
  • Beckwith Electric B-1612 Adapter
  • Beckwith Electric B-1652 Adapter
  • Beckwith Electric B-1685 Adapter
  • Beckwith Electric M-2035 Analog to Digital Interface Module
  • Beckwith Electric B-2291 Digital Input Guard
  • Beckwith Electric M-2406 Recloser Control Adapter Chassis
  • Beckwith Electric M-3908 Universal Contact Input Adapter
  • Beckwith Electric M-3801D IPS Plot Software
  • Beckwith Electric M-7651A D-PAC
  • Beckwith Electric M-2979 Recloser Control Cabinet
  • Beckwith Electric M-0359 SYNCROCLOSER MOD512
  • Beckwith Electric M-2001C-6ELFA Tap Changer Controller Voltage Regulator Control
  • Beckwith Electric M-0124 TERMINAL BOARD ADAPTER PLATE 13 POS
  • Beckwith Pride M-0296C 3ph Programmable Relay
  • Beckwith Electric M-0388 Syncrocloser Check Relay
  • M-0170A AC Current Relay Beckwith Electric
  • Beckwith Electric Intertie Protection M-3520 Instruction Manual
  • M-3311 M-3311 7113 BECKWITH ELECTRIC TRANSFORMER PROTECTION RELAY
  • Pride M-0296b 3 phase Programmable Relay Beckwith Electric Co
  • Beckwith Electric M3310 Integrated Transformer Protection Panel
  • Beckwith M-0145 First Customer Protector
  • Beckwith Electric M-0296C 3 phase Programmabel Relay
  • Beckwith Electric M-0389 VOLTAGE VERIFIER
  • M-3425 M-3425-A1DE BECKWITH ELECTRIC GENERATOR PROTECTION RELAY SL
  • Beckwith Electric M-0420 Multifunction Relay Protection Module 48VDC
  • M-3430 M-3430M0D515 BECKWITH ELECTRIC GENERATOR PROTECTION RELAY
  • Beckwith Electric Tapchanger Control M-0067E
  • Beckwith M-2001D-6L4S20C0S0X Tap Changer Control Surplus
  • BECKWITH ELECTRIC M3425A-STD1 Generator Protection 85-280VDC
  • Beckwith Electric High Speed Sync-Check Relay #M-0245C Mod #22 (NIB)
  • Beckwith Electric M-7679 R-PAC
  • Beckwith Electric TAPCHANGER CONTROL M-2001C-6SL