Description.

The 1785-L80B is an Allen-Bradley Enhanced PLC5 programmable logic controller (PLC).

The controller has 100.000 words of embedded user memory and is equipped with several communication interfaces.

Examples include four (4) DH/Remote I/O (adapters or scanners), one (1) configurable RS-232. -423. and RS-422A compatible serial port, and two (2) programming terminals.

It can accommodate up to 3072 arbitrary mixes or 3072 inputs and 3072 outputs in free mode!

About the 1785-L80B

The Programmable Controller 1785-L80B is the core component of every control system based on the Allen-Bradley PLC-5 Series.

The 1785-L80B connects local, expansion, and remote I/O modules on a variety of communication interfaces into a single control system.

There are four built-in ports on the 1785-L80B controller. The ports are labelled Channel 1A, Channel 1B, Channel 2A and Channel 2B.

All ports can be configured as remote I/O scanners, remote I/O adapters, and DH communication interfaces.

DH communications can be used both for remote programming and monitoring of the 1785-L80B and for creating peer-to-peer communication networks between various PLC-5 controllers.

The Remote I/O connection is used for real-time data exchange between the controller and I/O, operator interface and other functions.

All four channels on the 1785-L80B can be used as either remote I/O scanners or remote I/O communications adapters.

The Remote I/O Scanner mode reads and writes I/O information between the controller and remote I/O devices.

In this mode, the 1785-L80B is the supervisory controller for other controllers and remote I/O adapter modules that are in adapter mode.

When any of the four channels 1A, 1B, 2A, or 2B are operating in Remote I/O Adapter mode, the controller monitors the local I/O where its controllers reside.

It also communicates with the supervisory controller via the remote link. On the 1785-L80B, Data Highway+ (DH) links are available on all four available channels.

DH communications can be used to transmit data to other PLC-5 controllers or other advanced components of the control system.The DH link can be programmed to multiple PLC-5 controllers.

On the front panel of the 1785-L80B controller is a 25-pin connector labelled channel 0. This is an optically isolated EIA RS232C port.

Channel 0 supports ASCII and DF1 full-duplex and half-duplex master-slave protocols. There is a green channel 0 communication indicator on the front panel.

Next to channel 0. there are two 8-pin mini-DIN connectors labelled channel 1A and channel 2A, and a DH programming terminal connection parallel to channels 1A and 2A.

There are four three-pin connectors used as communication ports. These three-pin connectors are used for channels 1A, 1B, 2A, and 2B.

All of these ports can be used as Remote I/O Scanners, Remote I/O Adapters, or DH communication ports.The maximum cable length of the DH link depends on the transmission rate.

It is critical that all devices on the DH link communicate at the same rate. This length increases from a maximum of 3048 metres at 57.6 kilobits per second to 762 metres at 230.4 kilobits per second.

The 1785-L80B has multiple indicators on the front panel for easy interaction. The indicators show various controller statuses. The indicator labelled BATT shows the status of the battery.

The indicator labelled PROC indicates the current controller mode, green when the controller is in RUN mode and red when there is a problem.

The Allen-Bradley 1785-L80B is a PLC-5 series programmable logic controller (PLC).

It is part of the Enhanced PLC 5 series, which features, among other things, 100.000 words of embedded memory.

capable of holding up to 3.072 I/Os in any combination or 3.072 inputs and 3.072 outputs when operated in complementary mode.

The 1785-L80B is designed with multiple communication interfaces that can be used to communicate with different automation devices simultaneously.

It has four (4) DH/Remote I/Os (adapters or scanners) labelled CH1A, CH1B; CH2A and CH2B;.

One (1) configurable serial port for RS-232 and RS-422A electrical standards supporting the DF1 protocol, and two (2) programming terminals.

  • Kollmorgen S200 Series S20350-VTS SERVO DRIVE
  • Kollmorgen ServoStar CD CR06250 PRD-0030000z-45 , 1.4/2.2KVA Servo Drive Rev M
  • KOLLMORGEN AKD-P02407-NBEC-0000 Servo Drive
  • Kollmorgen ME2-405-B-A2 Goldline Servomotor-Encoder Commutated
  • KOLLMORGEN AKD-P00606-NBCC-I000 SERVO DRIVE
  • Kollmorgen MV65WKS-CE310/22PB Servo Drive Control Module 220v 22a
  • KOLLMORGEN SERVOSTAR 303 S3036 1-SE SERVO DRIVE
  • Kollmorgen S20360-VTS-021 Servo Drive
  • Kollmorgen MMC-SD-1.0-230-D (M.3000.0912) MMC Motion Control
  • Kollmorgen PRD-B040SAIZ-63 SERVO DRIVE CB06550
  • GE PQMII-T20-C-A Power Quality Meter
  • Eaton XV100-BOX-E4-DC1 EasyE4 Nano PLC, Starterset with DC Power supply
  • Eaton EASY-E4-DC-4PE1P easy programmable relays
  • Eaton EASY-E4-AC-12RCX1P easy programmable relays
  • Eaton EASY-E4-AC-12RC1P easy programmable relays
  • Eaton EASY-BOX-E4-UC1 Easy Nano Programmable Logic Controller
  • Eaton EASY-BOX-E4-DC1 Easy Nano Programmable Logic Controller
  • Eaton EASY-BOX-E4-AC1 easy programmable relays
  • Eaton XN-322-18PD-P Power feeder and distribution modules
  • Eaton XN-322-18PD-M Power feeder and distribution modules
  • Eaton XN-322-4PS-20 Power feeder and distribution modules
  • Eaton XN-322-1CNT-8DIO Technology modules
  • Eaton XN-322-1DCD-B35 Technology modules
  • Eaton XN-322-2DMS-WM Technology modules
  • Eaton XN-322-8AIO-U2 Analog input/output module
  • Eaton XN-322-8AO-U2 Analog output module
  • Eaton XN-322-4AI-PTNI Analog input modules
  • Eaton XN-322-10AI-TEKT Analog input module
  • Eaton XN-322-8AI-I Analog input modules
  • Eaton XN-322-7AI-U2PT Analog input modules
  • Eaton XN-322-12DO-P17 Digital output modules
  • Eaton XN-322-16DO-P05 Digital output modules
  • Eaton XN-322-20DI-PCNT Input/output modules
  • Eaton XN-322-20DI-PF Input/output modules
  • Eaton XN-312-GW-CAN Gateway modules
  • Eaton XN-322-20DI-PD Input/output modules
  • Beckhoff EL1814 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 10 µs, 3-wire connection
  • Beckhoff EL1819 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 10 µs
  • Beckhoff ED1829 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 3 ms, positive/ground switching, push-in
  • Beckhoff EL1429 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 3 ms
  • Honeywell X-DCS2000-E Digital Integrated System Manager
  • Automotion LC4A00010 DC BL Motor Control, ATS, Sub Assy, SCP, 115VAC
  • 500T-115VAC - VAS ENGINEERING - DORIC 500 SERIES DIGITSL TEMP INDICATOR - MODEL
  • ABB XZ C828 A101 Didt Dioder Snubber 3BHE039453R0101
  • ABB 3BHB027232R0001 1-Phase Charging Transformer
  • ABB 3BHE006412R0101 Circuit Board UFC762AE101
  • ABB XVC770BE101 3BHE021083R0101 Circuit Board
  • ABB 3BHE024747R0101 GD C801 A 3BHE024748 P104 high-voltage board
  • ABB 3BHE021887R0101 UBCC717BE101 Board 3BHB002751R0102
  • ABB 3BHE032593R0001 Isolated Power Supply
  • ABB 3BSC610023R0001 POWER SUPPLY SD812
  • Beckhoff ED1837 | EtherCAT Terminal, 32-channel digital input, 24 V DC, adjustable, push-in
  • Beckhoff EL1417 | EtherCAT Terminal, 32-channel digital input, 24 V DC, adjustable
  • Beckhoff ED1839 | EtherCAT Terminal, 16-channel digital input, 24 V DC, adjustable, push-in
  • Beckhoff EL1409 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 3 ms
  • Beckhoff ED1809 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 3 ms, push-in
  • Beckhoff EL1809 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 3 ms
  • Beckhoff EL1808 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 3 ms, 2-wire connection
  • Beckhoff EL1804 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 3 ms, 3-wire connection
  • Beckhoff EL1722 | EtherCAT Terminal, 2-channel digital input, 120…230 V AC, 10 ms, without power contacts
  • Beckhoff EL1712-0020 | EtherCAT Terminal, 2-channel digital input, 120 V DC, 3 ms
  • Beckhoff EL1712 | EtherCAT Terminal, 2-channel digital input, 120 V AC/DC, 10 ms
  • Beckhoff EL1702-0020 | EtherCAT Terminal, 2-channel digital input, 220 V DC, 3 ms
  • Beckhoff EL1702 | EtherCAT Terminal, 2-channel digital input, 120…230 V AC, 10 ms
  • Beckhoff EL1512 | EtherCAT Terminal, 2-channel digital input, counter, 24 V DC, 1 kHz
  • Beckhoff EL1502 | EtherCAT Terminal, 2-channel digital input, counter, 24 V DC, 100 kHz
  • Beckhoff EL1382 | EtherCAT Terminal, 2-channel digital input, thermistor, 30 ms
  • Beckhoff EL1262-0050 | EtherCAT Terminal, 2-channel digital input, 5 V DC, 1 µs, oversampling
  • Beckhoff EL1262-0010 | EtherCAT Terminal, 2-channel digital input + 2-channel digital output
  • Beckhoff EL1262 | EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs, oversampling
  • Beckhoff EL1259 | EtherCAT Terminal, 8-channel digital input + 8-channel digital output
  • Beckhoff EL1258-0010 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 1 µs, ground switching, multi-timestamp
  • Beckhoff EL1258 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 1 µs, multi-timestamp
  • Beckhoff EL1264 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 1 µs, oversampling
  • Beckhoff EL1254 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 1 µs, timestamp
  • Beckhoff EL1252-0060 | EtherCAT Terminal, 2-channel digital input, 10 V DC, 1 µs, timestamp
  • Beckhoff EL1252-0050 | EtherCAT Terminal, 2-channel digital input, 5 V DC, 1 µs, timestamp
  • Beckhoff EL1252-0010 | EtherCAT Terminal, 2-channel digital input, 24 V DC, 10 µs, timestamp
  • Beckhoff EL1252 | EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs, timestamp
  • Beckhoff EL1202 | EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs
  • Beckhoff EL1144 | EtherCAT Terminal, 4-channel digital input, 12 V DC, 10 µs
  • Beckhoff EL1134 | EtherCAT Terminal, 4-channel digital input, 48 V DC, 10 µs
  • Beckhoff EL1124 | EtherCAT Terminal, 4-channel digital input, 5 V DC, 0.05 µs
  • Beckhoff EL1114 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 10 µs, 2-/3-wire connection
  • Beckhoff EL1104 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 3 ms, 2-/3-wire connection
  • Beckhoff EL1098 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 10 µs, ground switching
  • Beckhoff EL1094 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 10 µs, ground switching
  • Beckhoff EL1088 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 3 ms, ground switching
  • Beckhoff EL1084 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 3 ms, ground switching
  • Beckhoff ELX1058 | EtherCAT Terminal, 8-channel digital input, NAMUR, Ex i
  • Beckhoff ELX1054 | EtherCAT Terminal, 4-channel digital input, NAMUR, Ex i
  • Beckhoff EL1054 | EtherCAT Terminal, 4-channel digital input, NAMUR
  • Beckhoff ELX1052 | EtherCAT Terminal, 2-channel digital input, NAMUR, Ex i
  • Beckhoff EL1052 | EtherCAT Terminal, 2-channel digital input, NAMUR
  • Beckhoff EL1034 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 10 µs, potential-free
  • Beckhoff EL1024 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 3 ms, type 2
  • Beckhoff EL1014 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 10 µs
  • Beckhoff EL1012 | EtherCAT Terminal, 2-channel digital input, 24 V DC, 10 µs
  • Beckhoff ED1008 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 3 ms, push-in
  • Beckhoff EL1008 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 3 ms
  • Beckhoff EL1004-0020 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 3 ms, isolation voltage 2500 V DC
  • Beckhoff EL1004 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 3 ms
  • Beckhoff EL1002 | EtherCAT Terminal, 2-channel digital input, 24 V DC, 3 ms
  • Beckhoff EK9520 | EtherNet/IP™ Bus Coupler
  • Beckhoff EK9500 | EtherNet/IP™ Bus Coupler
  • Beckhoff EK9320 | PROFINET RT Bus Coupler
  • Beckhoff EK9300 | PROFINET RT Bus Coupler
  • Beckhoff EK9160 | IoT Bus Coupler
  • Beckhoff EK9020 | Modbus TCP/UDP Bus Coupler
  • Beckhoff EK9000 | ModbusTCP/UDP Bus Coupler
  • Beckhoff EK3100 | PROFIBUS Bus Coupler
  • Beckhoff BK1250 | Compact coupler between EtherCAT Terminals and Bus Terminals
  • Beckhoff BK1150 | EtherCAT Compact Bus Coupler
  • Beckhoff BK1120 | EtherCAT Bus Coupler for standard Bus Terminals
  • Beckhoff EK1960 | TwinSAFE Compact Controller
  • Beckhoff EK1914 | EtherCAT Coupler with integrated digital standard and safety I/Os
  • Beckhoff EK1828-0010 | EtherCAT Coupler with integrated digital outputs
  • Beckhoff EK1828 | EtherCAT Coupler with integrated digital inputs/outputs
  • Kollmorgen AKT2G-BRC-000-000 Brake Chopper Terminal
  • Kollmorgen AKT2G-SM-L50-000 Stepper Motor Terminal, 50 V DC, 5 A, Vector Control
  • Kollmorgen AKT2G-SM-L15-000 Stepper Motor Terminal, 24 V DC, 1.5 A, Vector Control
  • Kollmorgen AKT2G-ENC-180-000 1-Channel Incremental Encoder Interface
  • Kollmorgen AKT2G-ENC-190-000 Incremental Encoder Interface with Differential Input
  • Kollmorgen AKT2G-AT-425-000 4 Ch Analog Outputs 0-10 and -10 to +10 Vdc
  • Kollmorgen AKT2G-AT-410-000 4 Ch Analog Outputs 0-10 and -10 to +10 Vdc
  • Kollmorgen AKT2G-SDO-004-000 4-channel digital output terminal, Safety
  • Kollmorgen AKT2G-DT-008-000 8 Ch Digital Output 0.5A
  • Kollmorgen AKT2G-SDI-004 4-channel digital input terminal, Safety