A Complete Line of Drives for a Complete Family of Products
Available in ratings from 0.37 to 448 kW (0.5 to 600 horsepower), the drive helps to provide a single
solution for virtually all of your speed control requirements. Commonality of design across the entire
range, coupled with identical control interface functions, device communications, training and
maintenance, provide you with a tremendous advantage in your control needs. Add that to integration
with Allen-Bradley SMC™ and SMP™ power products, the 1305 drive, the
1336 IMPACT™ and 1336 FORCE™ field-oriented control drives (all of which
use the same control interface and communication options) and you’ve just
gained significant advantage in system design, component integration,
operator training and maintenance.
Features
Protective
• Detection and Trip:
Undervoltage
Overvoltage
Drive Overcurrent
Overtemperature
External Signal
Drive Output Short
Ground Fault
Encoder Loss
At temperature
Load Loss
Single Phase
• Overcurrent Stall
• Overvoltage Stall
• Six Drive Alarms
• Fault Reset Input
Special Function
• Auto Economizer
• Process PI Controller
• Traverse Function
• Selectable Fault Reset & Run
• Auto Restart on Power Up
• Speed Sensitive Electronic Overload
• Auto-tuning
• Step Logic
Operational
• Selectable Volts/Hertz Mode
• Multi-lingual selection
Programmable
• Dual Accel/Decel Profiles
• Three Skip Frequencies
• DC Injection Braking
• Dynamic Braking
• Slip Compensation
• Negative Slip Compensation(Droop)
• S Curve Accel/Decel Profile
• Line Loss Restart Mode
• Proactive Current Limit
• Last Four Event Fault Memory
• Flying Start
• Seven Preset Speeds
I/O Interface
• Control Output Contacts
(2) Form A (N.O.)
(2) Form C (N.O. - N.C.)
Programmable to 17
different drive variables.
• Flexible Analog
Inputs/Outputs
• Pulse Train Input
• Encoder Feedback Closed
Loop Speed Control
• High Speed Input
Diagnostics
Real time preventive maintenance coupled with
customized status and fault reporting.
Depending upon your particular drive configuration, status and
fault conditions can be reported through the Human Interface
Module or through the SCANport™ Communications Port. Fault
diagnostic routines are started each time the 1336 PLUS II is
powered up. Throughout the entire run sequence, the drive will
continue to look for potential fault conditions.
To allow real-time preventive maintenance, drive output current
and control conditions can be selectively monitored while the drive
is running. The operator is made aware of alarm conditions such as
current limit, bus voltage status, motor overload or drive overload
before the drive reaches a fault level. Should a fault occur, plain
language diagnostic messages will help identify and isolate the
problem, allowing personnel to take quick, corrective actio
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com