Product properties
The ibaCom-L2B-x-8 cards are communication cards which are used to connect stan-dard
PC PROFIBUS master devices such as Simatic CPUs and CPs. The ibaCom-L2B-x-8 boards
are the successors of the L2B x-8-F PROFIBUS boards.
As far as this description does not refer explicitly to an ibaCom-L2B-4-8 or ibaCom-L2B-8-8.
the two boards are referred to as ibaL2B boards or cards
The ibaL2B card is, unlike most iba communication interfaces, a copper based inter-face
which holds 4 or 8 so called Profibus DP slaves.

The L2B features the followingfunctionality.
Compliant PCI V2.2 (5 V) board, needs one PCI-slot, Plug & Play functionality
I 1 Mbyte of PCI dual port ram for PC access
Standard PROFIBUS DP slave processors (SPC3)
No configuration jumpers or switches - fully software controlled
Firmware control in the PC without uninstalling the card
Dynamic reassigning of interrupt sources and interrupt generation (board and driversynchronization)
O Up to 4 ibaL2B boards can run in the same PC at the same time (board ids #0.. #3)4 DP slaves
on one PROFIBUS line (ibaL2B-4-8) or 2x4 DP slaves on 2 PROFI-BUS DP lines (ibaL2B-8-8-PCI)
O Each PROFIBUS-link has its own processor which controls and manages the fourslave-processors
ibaL2B supports DP multi master mode that means, that on one PROFIBUS lineseveral masters can
be present each controlling their corresponding slaves (onemaster for one slave only !)
For each slave (each slave represents an iba module which consists of 32 analogplus 32 binary signals)
the following telegram modes can be chosen:Integer
Real
S7-Real (Note in this mode there are only 28 Real values instead of the 32 nor-mally found)
QDA-Flatness (special mode for connection to Siemens flatness measurementsystems).
S7-Request
Each slave may send and receive data simultaneously (same telegram mode forboth directions)
LEDs for each PROFIBUS-line for CPU active (green), PROFIBUS-line o.k. (yel-low), internal error (red)
O 7-segment display for board id and synchronization status
Baud rates up to 12 Mbaud
Automatic baud rate detection
Profibus termination resistors for each PROFIBUS-line (switch)
100% compatibility to its predecessors on the PROFIBUS side (GSD data)
Scope of delivery
After unpacking check the completeness and intactness of the delivery.
The scope of delivery includes:
Device ibaCom-L2B-x-8
Manual
O Synchronization cable preassembled
GSD files
System requirements
Hardware
IBM-compatible PC with the following minimum configuration:
400 MHz Pentium II or better
128 MB RAM or better
At least one free PCI slot with 5V cable (V2.2. 5 V, 32/64 bit)
Software
0 Microsoft Windows NT4.0 (SP 6), 2000. XP, 2003. Win 7
PDA Version 4.07 with PCI support or higher or
ibaLogic V3.65 or higher