VM600 ABE056 Ultra Slim Racks
(houses the MPC4 mechanical protection card)
Key Features and Benefits
- From the vibro-meter® product family
- 19-inch slim rack with 1U standard height
- Rugged metal construction
- Modular concept allows the addition of specific modules (cards) for machine protection or condition monitoring
- Rack or panel mounting
- Backplane supports open collector (OC) bus and power distribution for VM600Mk2/VM600 systems
- Integrated AC input or DC input power supply
- Power check relay
Remarks
In general, the associated input/output module (card) is required and the relay module (card) is optional.
For safety reasons, VM600Mk2/VM600 rack slots that do not have a module (card) installed must
VM600Mk2/VM600 rack slots that do not have a module (card) installed must be covered by a blank panel.
AC Input Power
Input voltage range: 90 to 264 VAC
Input frequency range: 47 to 63 Hz
Input current: 2.5 A / 115 VAC or 1.5 A / 230 VAC
Output voltage: +5 VDC and ±12 VDC
DC Input Power
Rated input (line) voltage: 24 VDC
Input voltage range: 18 to 58 VDC
Input current: 3.0 A / 24 VDC
Output voltage: +5 VDC and ±12 VDC
Power check relay
Rated input (line) voltage: 110/220 VAC
Rated switching capacity (resistive load)
: 0.5 A / 125 VAC, 0.3 A / 110 VDC, 1 A / 30 VDC
Maximum switching voltage : ±30 VRMS / ±42.4 VAC (peak) or 60 VDC
Maximum switching current : 1 A
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com