Features
" From the Vibro-Meter® product family
" Relay card with screw terminal block
" 16 relays with changeover contacts
" Relay-driven inverted logic (jumper selectable)
" Low contact resistance
" Low capacitance
" High throughput power
" Real-time board insertion and removal (hot-swappable)
" EU EMC compliance
Maximum DC Load Breaking Capacity Curve
Operate/Release/Return Time: Typically 8 / 8 / 6 milliseconds
Dielectric strength test voltage
- Between open contacts: 1000 VAC
- Between contacts and coil: 4000 VAC
Mechanical life: 15 x 106 operations
Electrical life: >105 operations
Display: 16 relay PCBs
Relay status: Normal energized or normal de-energized (jumper optional)
External connections : Screw terminal connectors (J1. J2 and J3)
Mounting: Mounted on the rear of the VM600 rack and connected to the rack's backplane via connectors.
Rack Backplane
Temperature Range: See Relay Characteristics above
Humidity: ≤95% (non-condensing relative humidity)
RLC16 Power Supply
Supply voltage: +5 VDC
Consumption: 40 mA x 16 (per relay)
ENVIRONMENT
Operating environment
- Temperature : -25 to +65°C (-13 to +149°F)
- Humidity: 0 to 90% non-condensing