KEY FEATURES AND BENEFITS
• From the vibro-meter® product line
• Two measurement channels
(independently configurable)
• Measurement ranges:
Displacement:
100, 200 or 500 μm PEAK
Velocity:
10, 20 or 50 mm/s RMS
• Frequency range: 3 to 1000 Hz
• Temperature range: 0 to 50°C
• One 0 or 4 to 20 mA current loop output and
one “Raw” voltage output per channel
• Two alarms and three relays per channel
• Front-panel displays
• Robust steel housing with lockable
hinged door
• Protection rating: IP66
• Compatible with industry-standard
velocity sensors
APPLICATIONS
• Vibration measurement chains for machinery
protection and/or condition monitoring
• Vibration monitoring in accordance with
ISO 10816
• General-purpose vibration monitoring and
protection for stand-alone machines in harsh
industrial environments
DESCRIPTION
The VMS 830-2 vibration monitor from Meggitt’s
vibro-meter® product line is a dedicated vibration
monitor for use in vibration measurement chains.
The VMS 830-2 is a two-channel vibration monitor
that measures vibration displacement (PEAK)
and/or vibration velocity (RMS), using industrystandard velocity sensors.
Each VMS 830-2 measurement channel is
independently configurable to measure
displacement or velocity. Each channel provides
one 0 or 4 to 20 mA current loop output and a
buffered “Raw” voltage output signal. Further, for
each measurement, two alarms (Alert andDanger) and three relays (OK, Alert and Danger)
are supported. The alarms/relays are easily userconfigurable using potentiometers and DIP
switches. The VMS 830-2 also features LCD displays
to show measurement values.
During operation, the velocity sensor signal
(23 mV/mm/s) is converted by a preamplifier into
a standardized voltage signal (70.7 mV/mm/s). It
then passes through high-pass and low-pass filters
before being amplified by a two-step wide-band
amplifier to the level essential to the electronic
circuitry. It is user-configurable DIP switches that
determine which of the two possible
measurements/units – velocity or displacement –
is used for the vibration monitoring.
The DC-output signal (current loop output) is
available after true RMS rectification (RMS units).
The DC-output signal also acts with two
adjustable alarm level limit level detectors. The
response delay of the alarms/relays is set by DIL
switches to 1, 3, 5 or 10 seconds. The relays’
change-over contacts enable the Alert and
Danger circuits to operate as ether normally
energized (NE) or normally de-energized (NDE),
again, as set by DIL switches.
Accordingly, the VMS 830-2 vibration monitor is
recommended for the monitoring and protection
of stand-alone machines and auxiliary balance of
plant (BOP) equipment such as fans, pumps,
centrifuges, mills and gears. Among other things it
allows observation according to ISO 10816
(DIN 45665).
For evaluating the machine state, the VMS 830-2
vibration monitor provides velocity measurements
after machine-specific filtering and/or
displacement measurements (after additional
simple integration). Analog DC output signals
(current and voltage) corresponding to the
measured vibration are also provided.
Independently adjustable alarm level limits with
selectable response delay allow the
communication of Alert and Danger alarms via
appropriate assigned relays with dry contacts
(fail-safe-function).
For specific applications, contact your local
Meggitt representative.