S500 remote I/O
The availability of different fieldbus communi
cation interfaces makes it easy to use S500 I/O
modules as remote I/O for nearly any PLC and
PC. The S500 remote I/O station consists of a
communication interface and I/O modules. The
smallest configuration can be just the communi
cation interface with the onboard I/O channels.
Communication interfaces are available for the
following fieldbuses:
• PROFIBUS
• PROFINET/PROFIsafe
• EtherCAT
• Modbus TCP
• CANopen
• ABB CS31 System Bus
Easy engineering
The electronic configuration files that are
provided by ABB for different fieldbus systems
make it easy to configure the S500 remote I/O
station in your engineering tool. The files such as
GSD and GSDML are available for download at
www.abb.com/plc. For Modbus TCP remote I/O
stations a dedicated configurator is included in
Automation Builder and for larger applications a
Bulk Data Manager tool can be used.
AC500-eCo CPU as S500 remote I/O
When the AC500-eCo compact CPU is used as
remote I/O, it can be programmed with Automa
tion Builder for local intelligence while communi
cating via the open protocols Modbus TCP or
Modbus RTU with a CPU that will then be the
master of this intelligent remote I/O station. The
AC500-eCo CPU can be expanded by I/O modules
from the S500 and S500-eCo range.
S500 remote I/O with Modbus TCP
ABB provides a configurator in the Automation
Builder tool, which allows the configuration of
Modbus TCP I/O stations with the communica
tion interfaces CI521-MODTCP or CI522-MODTCP
in the same style as the AC500 configuration. For
larger applications a Bulk Data Manager tool can
be used. The configuration can be stored in the
communication interface, which allows using
the configured station with any PLC or PC that
supports Modbus TCP. This e.g. allows the use
directly on other controllers or monitoring
systems as e.g. ABB Ability™ Data Center Auto
mation or external systems.
Thanks to the Modbus feature that allows
several masters to exchange data with the same
slave, it is possible to use the I/O station as
shared devices with up to 10 PLC CPUs.
The Modbus masters can access the process data
of the I/O stations in two different ways:
• Fixed mode: each I/O module in the station
uses a separate register address range, which
requires separate Modbus read/write opera
tions for the modules in the station.
• The dynamic mode allows to pack the data of all
I/O modules in the station in one data structure
that can be exchanged in one single read/write operation.