Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

Eaton Power Xpert Meters PXM 4000/6000/8000

From:Eaton | author:Mr.Chen | Time :2026-09-30 | 25 view: | 🔊 Click to read aloud ❚❚ ▶ | Share:

Innovative. Intuitive. Accurate. Accessible.

The meters combine state-of-the-art technology with ITIC diagnostics,

waveform capture, data trending and performance benchmarking, along

with a “Twist-and-Click” graphic display: a new paradigm for simplicity

and ease of use in the marketplace. The embedded Web server enables

users to surf to the meter over the Internet via a standard Web browser.

The new platform offers advanced functionality like high-speed impulsive

transient capture, 6 MHz sampling rate (100.000 samples per cycle),

anti-aliasing, ITIC analysis and automatic trigger setting, field-upgradeable

firmware, memory up to 8 GB, and optional digital, relay and solid-state I/O.

Applications

Identify power quality problems to help

• Identify harmonics, sags, swells and transients damaging or

disrupting sensitive, mission-critical IT equipment

• Boost IT equipment service life to the maximum

• Analyze sequence of events up to one millisecond time resolution

• Protect motors from damage

• Preserve the integrity of processes and batches

• Prevent blown capacitor bank fuses

• Protect transformers and conductors from overheating

Detect and record high-speed transients to help

• Avoid equipment damage and disruption

• Identify equipment malfunction

Monitor circuit loading to help

• Avoid overloads and nuisance overload trips

• Maximize equipment utilization

• Manage emergency overloads

Manage energy utilization to help

• Reduce peak demand charges and power factor penalties

• Identify excessive energy consumption

Features and benefits

• Embedded Web server—see and analyze waveforms, trends

and harmonics directly in your Web browser or LCD meter

graphic display

• Automatic power quality analysis and trigger setting with

available ITIC performance curve: detect and capture sags, swells,

transients, harmonics and flicker

• Accurately detect fast transients that previous generation

monitors would miss, by assessing circuit activity at very high

sampling rates (up to 100.000 samples per cycle)

• Comprehensive power, energy and demand measurements

for 145 standard data points logged

• Voltage, current: per phase minimum, maximum, average,

trend graph analysis, export, print

• Power: power factor, apparent, real, reactive, frequency

• Energy, demand: forward, reverse, net, sum, TOU, profile,

previous month comparison, graph analysis, export, print

• Up to one millisecond time synchronization and event logging

capability for sequence of events analysis

• Get an at-a-glance view of power quality with patented

Power Quality Index gauge, statistically derived trending

and red-yellow-green indicators for overall power health

• Support continuous, non-disruptive monitoring with a permanently

installed meter

• Dramatically reduce the cost of monitoring power quality,

compared to yesterday’s specialized power quality instruments

and consultants

• Alarm notifications are also available remotely via e-mail

with waveform attached, with expansion communication card

• Use industry-standard communication protocols to support a

multitude of configurations and third-party software: HTTP, FTP,

Modbus RTU, Modbus TCP, SNMP, SMTP, NTP, COMTRADE

• Up to 8 GB data storage capability

• Supported via Power Xpert Software and Power Xpert

Architecture hardware components

• ANSI C12.20 accuracy

Three flavors of power monitoring

The Power Xpert Meter 4000

This meter provides all the core functions for monitoring power

consumption and power quality along with 2 GB of data storage.

This unit uses Delta Sigma technology to sample circuits at 4.096

samples per cycle for extremely accurate measurement of power

factor and energy consumption.

The Power Xpert Meter 6000

This meter is geared toward the IT market by providing automatic

trigger settings for IT equipment and plots events on an ITIC

(Information Technology Industry Council) performance curve so

they can be very easily analyzed. In addition, this meter offers a

patented Power Quality Index temperature gauge along with flicker

calculations and 4 GB of data storage.

The Power Xpert Meter 8000

This meter adds the ability to capture very fast transients by

sampling at 6 MHz—100.000 samples per cycle. That’s a sample

  • Eaton 1023843 Power Board B20098140711 A5
  • Eaton PDG23F0125VFFJ Power Defense molded case circuit breaker
  • Eaton 9130 1KVA Marine Filter Pn 1029424 Rev 002 220/230/240VAC 50/60Hz 1603
  • Eaton/Dynamatic 15-871-6 AF5000+ Power Supply Board P-CTR 158716
  • EATON D80JE22A PNEUMATIC TIMER SER.A2
  • Eaton - Cutler Hammer PXM1000MB15-1 PXM 1000 METER; DISPLAY; 5A; 100-415AC/1
  • Eaton Cutler Hammer IQDP-4000 IQ DP-4000 66D2040G03
  • Eaton F801 8 Segment Redundant Fieldbus Power Supply
  • Eaton PXM-4KUPG Power Xpert Meter 4000 to 6000 license upgrade key
  • Eaton PX-PMBC Panel mounting bracket assembly required for reduced graphic display rear clearance
  • Eaton PX-PMBB Panel mounting bracket assembly for retrofitting a graphic display to an IQ analyzer cutout
  • Eaton PX-PMBA Panel mounting bracket assembly for back-to-back meter to graphic display mounting
  • Eaton PXMCE-B Communications expansion card: Ethernet 100FX, 10/100T, RS-485, RS-232
  • Eaton PXMIO-B Digital I/O card: 8 digital input, 2 solid-state output, 3 relay output
  • Eaton PXD-MMG Graphic display module
  • Eaton PXM4051A1AB Power Xpert meter 4000
  • Eaton / Cutler Hammer PXM4000 PXM4051A1BB
  • Basler Electric BE1-59-A4E-E1C-A0N0F / BE159A4EE1CA0N0F Over Voltage Relay
  • Basler Electric SR4A-2B05A3E Static Voltage Regulator SR4A2B05A3E
  • Basler Electric 9-0723-00-130 / 9072300130
  • Basler Electric BE1-79MA10A6JC0L0F / BE179MA10A6JC0L0F
  • Basler Electric CBS-377 CURRENT BOOST SYSTEM PART NO 91096001
  • Basler Electric SR4A1B05A3A Static Voltage Regulator 480v-ac 62.5v-dc 10va
  • Basler Electric BE159N A7ED1JC0S0F Solid State BE159N-0 Protective Relay
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K2EW6MB1N0F
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50 Style G4EA1RG0N0F
  • Basler Electric BE1A-25-M1G-A6T-N4V1F Sync-Check Relay
  • Basler Electric SR8A2B10B1A STATIC VOLTAGE REGULATOR
  • BASLER TIME OVERCURRENT RELAY BE1-51A SOLID STATE 1 PH
  • Basler Electric SSR 125-12 STATIC VOLTAGE REGULATOR 9185900102
  • Westinghouse 2374A07G03 Power Supply Basler Electric 90-73900-102
  • 9400200117 - Basler Electric - CONTROL POWER UNIT - 12/24VDC 20WATT
  • Basler Electric Static Voltage Regulator SR32A2B05B3E
  • Basler Electric SR8A2B06B3A Static Voltage Regulator / SR8A2BO6B3A
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY B1EZIPB1N0F
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50-51B-219
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EW6MB0N0F
  • Basler Electric SBO226 Excitation Support System
  • Basler Electric SBO225 Excitation Support System
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EZ1PA0N0F
  • Basler Electric MOC3502 | 90-72300-116 MOTOR POTENTIOMETER
  • Woodward 1751-6058 4 Channel MPU Transformer Module
  • Basler Electric 2D80367G23 DXCB De-Excitation Module 1200V 5000A Excite
  • Basler Electric SSR 63-12-9185900101 Static Voltage Regulator
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EW5MB0N0F
  • Basler Electric MODEL SSR 125-12NF STATIC VOLTAGE REGULATOR 9 1859 00 106
  • Basler Electric Breaker Protection Relay BE1-BPR 9272000315
  • Basler Electric SBO224 Excitation Support System
  • Basler Electric SSR 63-12 Static Voltage Regulator 9 1859 00 101 46534AB
  • Basler Electric AEM-2020 ANALOG EXPANSION MODULE
  • Basler Electric BE 25231-001 Transformer BE25231001
  • Basler Electric PSS-100-Y5 Power Sys Stabilizer dampening oscillations 0.1-5.0Hz
  • Basler Electric BE1-87G-S1A-A1C-A0N0 Variable Percentage Differential Relay
  • Basler Electric SR8A-2B06B3E Static Voltage Regulator SR8A2B06B3E
  • Basler Electric SOLID STATE FREQUENCY CONTROLLER SCP-210 /SCP210 P/No:9095400100
  • Basler Electric BE1-59-A3E-A1J-N1N3F / BE159A3EA1JN1N3F Over Voltage Relay
  • Basler Electric SBO223 Excitation Support System
  • Basler Electric P/N 9 2011 11 100 BRACKET MOUNTED TERMINAL UNIT
  • Basler Electric P/N 9 2011 11 100 BRACKET MOUNTED TERMINAL UNIT
  • Basler Electric voltage regulator P/n: 9 1606 00 101
  • Basler Electric Current Boost System | Model No. CBS-377 P/N 9109600102
  • Basler Electric 8650C72 Exciter Control Module Pcb Board Rev 5
  • Basler Electric 9252000258 Be1-50/51b Overcurrent Relay
  • Basler Electric SR8A-2B01B3A Static Voltage Regulator SR8A2B01B3A
  • Basler Electric SR4A-2B01B3E Static Voltage Regulator SR4A2B01B3E
  • Basler Electric 9017709102 PC Board
  • Basler Electric 9066800102 Excitation Support Systems 9066800-102
  • Beckhoff ELX3152-0090 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELX3158 | EtherCAT Terminal, 8-channel analog input, current, 4…20 mA
  • Beckhoff ELX3152 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3704-1001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0020 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3702-0101 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3702-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3604-0002 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3604-0000 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0032 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0030 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0002 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0000 | EtherCAT Terminal, 2-channel analog input
  • Beckhoff ELM3544-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3542-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • ENOTEC GAS ANALYZER SYSTEM OXITEC 5000 SME-53310000
  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch