The PLX51-PBM gateway provides connectivity to EtherNet/IP™, Modbus TCP/IP®,
or Modbus® Serial networks for PROFIBUS DP networks by operating as either a
Master or Slave device on the PROFIBUS DP network.
For easy integration to a Rockwell Automation Controller, the gateway and
configuration software create dynamic AOI’s based on the user configuration to add
logical tag names to the PLC project file. Thus, reducing the overall programming
time for EtherNet/IP applications.

For configuration of Modbus TCP/IP or Modbus Serial Networks, the module will
automatically map PROFIBUS DP data points to registers on a Modbus network.
With advanced tools such as PROFIBUS device discovery and a built-in PROFIBUS
DP packet capture utility, PROFIBUS DP network commissioning time can be greatly
reduced.
Dual Ethernet ports of the module can support either DLR (Device Level Ring)
topology, or can be used as an embedded switch for flexible installation options.
With support for up to 1536 bytes of Input and Output data, and up to 4 EtherNet/IP
connections to the processor, this module provides performance and data throughput
back to the processor for even the most demanding of PROFIBUS applications.
When used as a PROFIBUS DP slave, the module can operate as 1 to 10 slaves,
providing up to 1536 bytes of Input and Output Cyclic I/O data between EtherNet/IP,
Modbus TCP/IP, or Modbus Serial devices and a PROFIBUS DP master.
Features
Supports DLR for EtherNet/IP networks
Support for either EtherNet/IP, Modbus TCP/IP, or Modbus Serial Communication networks
PROFIBUS master or slave (with multi-slave support)
Built-in PROFIBUS packet capture tool
Configuration
The PLX50 Configuration Utility software is used for configuration and troubleshooting of
the module. The stand-alone configuration utility allows users to define the setup and
configuration of the PROFIBUS DP network, connections with Rockwell Automation
controllers and devices over EtherNet/IP, and build custom Add-On Instructions (AOIs)
to be imported into Studio 5000 applications.
With the ability to import custom AOI’s into the Studio 5000 environment and advanced
PROFIBUS DP tools such as the packet capture utility, commissioning time of a network
can be greatly reduced.
EtherNet/IP Server (Class 1 Adapter)
As an EtherNet/IP server, the gateway operates as an Adapter with up to 4 Class 1 I/O
connections to a Controller (Scanner) on an EtherNet/IP network. The use of
EtherNet/IP Class 1 I/O connections for transfer of PROFIBUS DP cyclic data, provides
fast data transfer between networks for increased performance on time critical
PROFIBUS DP applications.
Modbus TCP/IP
On a Modbus TCP/IP network, the module will operate as either a Modbus TCP/IP
Client or Server device.
As a Modbus TCP/IP client the module can be configured to automatically read/write all
PROFIBUS DP data with a slave device for easy setup and configuration, or the
Modbus Auxiliary Map feature will allow you to configure data transfer to customize the
mapping to meet specific application requirements.
As a Modbus TCP/IP Server all information from the PROFIBUS DP network is stored in
continuous registers in the module for easy configuration and efficient mapping of data
to a Modbus TCP/IP client.
Modbus Serial
On a Modbus Serial network the module will operate as either a Master or a Slave
device supporting either RS232 or RS485 communication networks.
As a Modbus Serial Master the module can be configured to automatically read/write all
PROFIBUS DP data with a slave device for easy setup and configuration, or the
Modbus Auxiliary Map feature will allow you to configure data transfer to customize the
mapping to meet specific application requirements.
As a Modbus Serial Slave all information from the PROFIBUS DP network is stored in
continuous registers in the module for easy configuration and efficient mapping of data
to an attached master device.
PROFIBUS DP Master V1
Cyclic or acyclic data can be transferred with Class 1 or Class 2 DPV1 services,
allowing communication with slave devices supporting PROFIBUS DPV0 or V1
protocols. The gateway acts as an input/output link between the PROFIBUS network
and the EtherNet/IP protocol. Data transfer by the EtherNet/IP protocol is asynchronous
from data transfer on the PROFIBUS network.
Easy-to-use drag and drop configuration interface via ProSoft PLX50 Configuration
Utility
GSD file import library
Monitoring and Modification of process data and DPV1 acyclic data
Multi-drop on a PROFIBUS DPV1 network with other compatible devices
Automatic project documentation, and Bus Parameter calculation
Supports online slave diagnostics, and extended diagnostic data (DPV1)
Auto baud detection at all valid PROFIBUS DPV1 rates up to 12 Mbps
Master Status LED Indicators for Operations, Network Communication, Master
Token-Hold and Network Configuration.
Up to 125 Slaves can be connected with a repeater
Up to 1536 cyclic bytes input and 1536 bytes output data
Supports Extended Diagnostic Data
Alarm Handling (DPV1)
Supports Sync and Freeze commands
Supports PROFIdrive 3.1 compliant parameter read and write operations
Supports Multicast and Broadcast telegrams (DPV1)