Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

PCH Engineering PCH 1026 Digital Wind Turbine Structure Vibration Monitor

From:PCH Engineering | author:Mr.Chen | Time :2024-07-10 | 1787 view: | 🔊 Click to read aloud ❚❚ | Share:

Purpose

- Long-term monitoring of low-frequency structural and seismic vibration

APPLICATIONS

- Wind turbines

- Tower vibration

- Drive train vibration (pitch turbines)

- Blade edge vibration (stall turbines)

- Steel towers

- Chimneys

- Bridges

- Buildings

- Seismic Vibration to ISO4866

Configuration and Setup

- Setup and configuration can be performed through the serial RS-232 port using the supplied Setup and Monitoring PC program, CHT 1012. All settings can be changed in the field.

- Setup and display can also be performed remotely from an external PC or controller (e.g., WTC or process controller) via an optional RS-485 connection.

- A log in the PC software records monitor-specific settings and identifies the instrument by its serial number.

Features

- 3 internal vibration sensors (accelerometers)

- Triaxial measurements in A, B and C directions

- Omni-directional tower monitoring

- Proven optimal tower monitoring

- Up to 4 different frequencies can be monitored independently, one frequency per transducer or up to 4 different frequencies per transducer

- Proven filter technology based on wind turbine application experience

- Measurement of RMS, Maximum, Peak or Peak values

- 1 - 4 independent industry standard 4-20mA outputs

- 4 independent alarm relays with programmable brake/break function and 1 system fault relay

- Programmable alarm thresholds and independent delay times for each alarm relay

- Internal continuous watchdog for sensors and electronic circuitry. Fault indication on system fault relay.

- Test functions for all sensors and electronic circuits.

- Designed for harsh environments including temperature, electrical noise interference and humidity.

- Customised monitoring algorithms are available to differentiate the customer from the competition.

Configuration

The PCH 1026 is a self-contained monitor in a sealed, rugged case. It requires only DC power and the required output connections to operate.

Required.The PCH 1026 is designed for low frequency monitoring applications.

Built-in vibration sensors in 3 directions: Built-in vibration sensors in 3 directions: X, Y and Z.

Includes test functions for all sensors and electronic circuits, as well as an internal watchdog for continuous self-monitoring functions.

The design of the PCH 1026 is based on a digital platform that provides customers with a wide range of solutions and allows for quick configuration and setup changes in the field.

Signal Conditioning

All signal conditioning is performed digitally.

This means that settings and configurations can be changed and verified via the included PC software programme (CHT1012).

Digital signal processing is performed by state-of-the-art DSP technology, ensuring accurate and efficient monitoring.

Selective monitoring of frequencies or bands of interest can be achieved by choosing from a variety of high and low pass filters. Simply select from which frequency to monitor.

The PCH 1026 has a wide range of filters that have been proven over many years of industry experience.

Alarm and System Fault Relays

Alarm Relays:

The PCH 1026 provides 4 independent alarm relays with programmable "on" or "off" functions.

All 4 relays can be assigned to the desired frequency or measurement direction.

For example one relay is responsible for the desired frequency, or the same relay can be responsible for up to 4 different frequencies.

Alarm threshold levels, delay times, latching or non-latching functions can be set independently for each relay using the supplied PC software.

System Failure Relay:

The PCH 1026 provides system fault relays with disconnects for optimum fail-safe configurations.

Configuration. A fault detected by the PCH 1026's internal watchdog will trigger the system fault relay in either test mode or monitor mode.

The system fault relay responds to the following conditions: power failure, overload, processor stop, sensor failure.

Related Product Recommendations:

5X00419G01 Ethernet Link Controller

1769-PB4 Power Module

IC660TBD025 GeniusI/O Terminal Assembly Module

BSFC-01C Charge Controller Board SP Kit Gate Driver Boards

IC660TBD024K GeniusI/O Terminal Assembly Module

1769-OF8C Analog Output Module

ILX56-MM Message Manager for Industrial Communications

BSFC-02C Charge Controller Universal Brake Chopper

1769-OF2 Analog Output Module

  • Triconex 3723X Analog Input Input Module with HART
  • GE IS420ESWAH5A Mark VIe IONet Switch
  • GE IS420ESWAH4A Mark VIe IONet Switch
  • GE IS420ESWAH2A Mark VIe IONet Switch
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51M, Self-Powered Time Overcurrent Relay
  • Basler Electric BE1-50/51B, Self-Powered Time Overcurrent Relay
  • Basler Electric BE1-11m, Motor Protection System
  • Basler Electric BE1-11t, Transformer Protection System
  • Basler Electric BE1-11d, DC Power Protection System
  • Basler Electric BE1-11i, Intertie Protection System
  • Basler Electric BE1-11g, Generator Protection System
  • Basler Electric BE1-11f, Feeder Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES-25, Sync-Check Relay
  • Basler Electric ES-27, Undervoltage Relay
  • Basler Electric ES-27/59, Under/Overvoltage Relay
  • Basler Electric ES-32, Reverse Power Relay
  • Basler Electric ES-37, Undercurrent Relay
  • Basler Electric ES-37/51, Under/Overcurrent Relay
  • Basler Electric ES-47, Phase Sequence Relay
  • Basler Electric ES-47N, Phase Balance Relay
  • Basler Electric ES-47N/27, Phase Balance/Undervoltage Relay
  • Basler Electric ES-49, Temperature Relay
  • Basler Electric ES-51, Overcurrent Relay
  • Basler Electric ES-55, Power Factor Relay
  • Basler Electric ES-59, Overvoltage Relay
  • Basler Electric ES-74V, DC Voltage Sensing Relay
  • Basler Electric ES-81O, Overfrequency Relay
  • Basler Electric ES-81O/U, Over/Underfrequency Relay
  • Basler Electric ES-81U, Underfrequency Relay
  • Basler Electric DECS-250-CN1SN1N Digital Excitation Control System
  • Beckhoff EL2622-0010 EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2622 | EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2612 | EtherCAT Terminal, 2-channel relay output, 125 V AC, 30 V DC, 0.5 A AC, 2 A DC
  • Beckhoff EL2602-0010 EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2602 | EtherCAT Terminal, 2-channel relay output, 230 V AC, 30 V DC, 5 A
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2574 | EtherCAT Terminal, 4-channel LED output, pixel LED
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output
  • Beckhoff EL2535-0100 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2535-0050 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output
  • KEBA KEVIEW V2 341/C-4400 HMI TOUCHSCREEN UNIT
  • KEBA KEMRO K2-200 BL250/A BL 250/A Bus Coupler Module
  • Keba E-CON-14 Operator Interface Panel
  • KEBA CP 255/W Plc Module
  • KEBA CU 212 ZENTRALBAUGRUPPE
  • KEBA CU211/0 25817 Ind 06
  • KEBA RS 091 POWER SUPPLY MODULE
  • KEBA E-SP-CCEC/22180 Panel
  • KEBA E-CPU-186B Control Circuit Board D1633C
  • Keba Kemro K2-200 Control CP 255/X, Part. 072076
  • KEBA analog module, AR281, AR 281
  • KEBA BL250/B Bus link module
  • KEBA Kemro K2-400, DO 470/A, Part No. 054945
  • KEBA HAITAN SA900 Operator Panel
  • KEBA DO 321 module DO 321/B
  • KEBA KeTop C20t-t00-Ar0-KMT Tech Pendant by Karl Mayer
  • KEBA HT401/BENNINGER/5M/55268 TEACH PENDANT HT401BENNINGER/5M/55268
  • KEBA AR 281 ANALOGE INPUT BOARD
  • Engel Keba EC100 PLC Rack with PS244 CU211 PD242 AR181 TT081 DO321 DI325 (19821)
  • KEBA CU 313 Central Unit CU 313/C-SI/63036 Card 128MB
  • KEBA TM-240/A PLC MODULE
  • Keba D1633C E-Cpu-186B Cpu Control Circuit Board W/ D1630D
  • Keba Engel E-CON-CC100/A/22178 HMI Operator Control Display Panel
  • KEBA K2-200 CP 242/B controller module
  • KEBA KEVIEW V2 341/C-4400 HMI TOUCHSCREEN UNIT 84494 24 VDC
  • KEBA E-8-THERMO 1770B-1 Thermocouple circuit board
  • KEBA 3HAC12929-1 TEACH PENDANT
  • Keba KETOP C50 R/73810/06 KEBA PANEL OPERATOR DISPLAY
  • KEBA Kemro K2-400 DO 470/B 059707 Module
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Beckhoff EL2502-0010 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2502 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 0.5 A
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protectio
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • SAACKE FSC-01V3.02/V3.00 Industrial Combustion Controller
  • GE Multilin 750-P5-G5-S5-HI-A20-G 750 Management Relay
  • GE Multilin 750-P5-G5-D5-HI-A20-R 750/760 Feeder Mgmt Relay Series
  • GE Multilin 750-P5-G5-D5-HI-A20-G Management Relay
  • GE Multilin 750-P5-G1-D5-HI-A20-R Multilin 1A Zero Sequence Current Inputs
  • GE Multilin 750-P1-G1-S1-HI-A20-R-T-H Feeder Management Relays
  • GE Multilin 750-P1-G1-S1-HI-A20-R Feeder Management Relays
  • GE Multilin 750-P1-G1-D1-HI-A20-R Base Unit 750 Relay
  • GE Multilin 239-RTD-AN-H motor protection relay
  • GE Multilin 489-P5-HI-A20-T-H Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-T Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-E-H Relay Motor Management
  • GE Multilin 489-P1-LO-A20 489 Motor Management Relay Base Unit
  • GE Multilin SR469-P5-LO-A20-T Motor Management Relay
  • GE Relay from GE Grid Solutions SR469-P5-LO-A20-E
  • GE Multilin SR469-P5-LO-A20 Motor Management Relay with Case
  • GE Multilin SR469-P5-HI-A20-T 469 Series Relay
  • GE Multilin SR469-P1-HI-A1-E-H 469 Series Relay
  • GE Multilin SR469-P1-H1-A1-E 469 Series Relay
  • GE Multilin 469-P5-LO-A20-T Phase Current Input 5 A Phase CT Secondaries
  • GE Multilin 469-P5-LO-A20-E LO Control Power with 4-20mA Analog Outputs
  • GE Multilin 469-P5-LO-A20 Motor Management Relay
  • GE Multilin 469-P5-HI-A20-E-H Motor Management Relay