NI PC-LPM-16/PnP Installation and Configuration Multifunction I/O Board for the PC

From:NI | author:Mr.Chen | Time :2024-12-12 | 1011 view: | 🔊 Click to read aloud ❚❚ | Share:

Hardware Installation

You can install the PC-LPM-16PnP in any available expansion slot in

your computer. The following are general installation instructions, but

consult your computer user manual or technical reference manual for

specific instructions and warnings.

1. Turn off and unplug your computer.

2. Remove the top cover or access port to the I/O channel.

3. Remove the expansion slot cover on the back panel of the computer.

4. Insert the PC-LPM-16PnP board into any 8-bit or 16-bit slot. It may

be a tight fit, but do not force the board into place.

5. Screw the mounting bracket of the PC-LPM-16PnP board to the

back panel rail of the computer.

6. Replace the cover.

7. Plug in and turn on your computer.

The PC-LPM-16PnP is installed.

Software Installation

If you are using NI-DAQ, refer to your NI-DAQ release notes to install

your driver software. Find the installation section for your operating

system and follow the instructions given there.

If you are using LabVIEW, refer to your LabVIEW release notes to

install your application software. After you have installed LabVIEW,

refer to the NI-DAQ release notes and follow the instructions given

there for your operating system and LabVIEW.

If you are using LabWindows/CVI, refer to your LabWindows/CVI

release notes to install your application software. After you have

installed LabWindows/CVI, refer to the NI-DAQ release notes and

follow the instructions given there for your operating system and

LabWindows/CVI.

If you are a register-level programmer, refer to Appendix D, Register-

Level Programming, for software configuration information.

Board Configuration

Plug and Play

The PC-LPM-16PnP is fully compatible with the industry-standard

Intel/Microsoft Plug and Play Specification version 1.0a. A Plug and

Play system arbitrates and assigns resources through software, freeing

you from manually setting switches and jumpers. These resources

include the board base I/O address and interrupt channels. Each

PC-LPM-16PnP is configured at the factory to request these resources

from the Plug and Play Configuration Manager.

The Configuration Manager receives all of the resource requests at

startup, compares the available resources to those requested, and

assigns the available resources as efficiently as possible to the Plug and

Play boards. Application software can query the Configuration

Manager to determine the resources assigned to each board without

your involvement. The Plug and Play software is installed as a device

driver or as an integral component of the computer BIOS.

Base I/O Address and Interrupt Selection

You can configure your PC-LPM-16PnP to use base addresses in the

range of 100 to FFF0 hex. The PC-LPM-16PnP occupies 16 bytes of

address space and must be located on a 16-byte boundary. Therefore,

valid addresses include 100, 110, 120…, FFE0, FFF0 hex. This

selection is software-configured and does not require you to manually

change any settings on the board.

The PC-LPM-16PnP can use interrupt channels 3, 4, 5, 6, 7, and 9.

There are different ways to assign the base address to your board:

• For Windows 95, the base address and interrupt should be set

automatically. However, if you want to view or change these

settings, you can set the board resources using the Device

Manager. Windows 95 will automatically allocate resources, but

these can be changed in the Device Manager:

a. Click the right mouse button on My Computer to bring up system properties.

b. Select Device Manager.

c. Select Data Acquisition Devices.

d. Select the PC-LPM-16.

You can change address and interrupt settings on the Resources page.

• For Windows 3.10 or 3.11, you can use the NI-DAQ Configuration

Utility (formerly WDAQCONF) to assign the board resources. If a

standard configuration utility is present in the system, you will not

be able to modify the board resources.

• You can use a standard configuration utility like Intel ISA

Configuration Utility (ICU). ICU dynamically assigns the base

address to your board when you boot up the computer. You can also

lock the board resources when you use ICU. For additional

information on ICU, contact Intel Corporation for a copy of Plug

and Play Specification version 1.0a.

Non-Plug and Play

To configure the non-Plug and Play PC-LPM-16 board, refer to

Appendix C, Using Your PC-LPM-16 (Non-PnP) Board.

  • DEIF MVR-F215 Product description
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF PPM 300 Protection & power management
  • DEIF RMC-142D Current relay
  • DEIF GPU-3 hydro Generator protection unit
  • DEIF MVR-200 series Medium Voltage Relay
  • DEIF RMC-131D Current relay
  • DEIF MDR-2 Multi-differential relay
  • DEIF AGC 150 ATS: Advanced Generator Transfer Switch for Seamless Power Management
  • DEIF DVC 350 Digital automatic voltage regulator (AVR)
  • DEIF Digital Voltage Controller DVC 550
  • DEIF TAS-331DG AC transducer for active or reactive power
  • DEIF RMV-112D Undervoltage and overvoltage relay
  • DEIF DPS-1 DC Power Supply
  • DEIF DM 400 hydro Integrated systems
  • DEIF DBC-1 Battery charger
  • DEIF CSQ-3 Multi-function synchroscope
  • DEIF CODESYS Features Software - AWC 500 development package
  • DEIF AMC 300 Advanced Programmable Controller
  • DEIF AGI 400 Advanced graphical interface
  • DEIF BRW-2 & BW Analogue illuminated bridge wing indicators
  • DEIF AWC 500 - G59/3 Integrated G59/3 protection turbine controller unit
  • DEIF AWC 500 Advanced Controller
  • DEIF ASK & ASR Measuring transformer
  • DEIF ASC-4 Battery Automatic Sustainable Controller
  • DEIF ASC plant management Automatic sustainable controller
  • DEIF AOP Additional operator panel
  • DEIF AMC 600 Programmable automation controller with EtherCAT based I/O
  • DEIF AL8-2 Alarm panel
  • DEIF AGC 150 Hybrid Advanced Genset Controller
  • DEIF AGC 150 PMS Lite Simple power management controller
  • DEIF AGC 150 Generator Advanced Genset Controller
  • DEIF AGC 150 Remote Display Remote access and control unit
  • DEIF MVR-250 series Medium Voltage Relay
  • DEIF MVR-210 series Medium Voltage Relay
  • DEIF The SGC series
  • DEIF iE 350 Marine Highly flexible and cybersecure intelligent energy controller
  • DEIF iE 250 Marine Versatile and cybersecure intelligent energy controller for maritime applications
  • DEIF iE 150 Marine Simple and effective power management
  • DEIF iE 650 PLC Extreme robust Programmable Automation controller with EtherCAT based I/O
  • DEIF iE 350 PLC Robust right out of the box
  • DEIF iE 250 PLC Versatile and modular intelligent energy PLC controller
  • DEIF XL / BW / BRW-2 Illuminated indicators
  • DEIF SGC 120/121 Single Genset Controllers
  • DEIF Load Sharing Unit LSU-112DG
  • DEIF Automatic Genset Controller AGC-4
  • DEIF DU-2/MKIII Paralleling And Protection Unit 24VDC
  • DEIF AGC-4 Mk II Generator Set Automatic Controller
  • DEIF GPU-3 graphics card Generator protection unit
  • DEIF SGC 410 Single Genset Controller
  • DEIF SGC 110 Single Genset Controller
  • DEIF MTR-3 Multi-sensor
  • HIMA HIMax® HART Communication Module X-HART 32 01
  • HIMA 22121 Output modules
  • HIMA 22120 Output modules
  • HIMA 32110 Relay Amplifier – SIL 4 Certified Safety Module
  • HIMA 32103 Relay Amplifier – SIL 4 Certified Safety Module
  • HIMA 32102 Relay Amplifier – SIL 4 Certified Safety Module
  • HIMA 32102 Relay Amplifier – SIL 4 Certified Safety Module
  • 32100 | HIMA 2 Channel Relay Amplifier
  • HIMA 42500 Selection element,2003 voting Logic function modules
  • HIMA 42400 Blocking element, direct and inverted output Logic function modules
  • HIMA 42300 OR element with 2 inputs Logic function modules
  • HIMA 42200 Element combination AND/OR/blocking element Logic function modules
  • HIMA 42100 AND element with S inputs, 1 with OR Logic function modules
  • HIMA 52100 Time Delay Module
  • HIMA 62100 984162100 2-Fold Analog Limit Monitor
  • HIMA 80110 Reset module
  • HIMA HIMatrix Safety-Related Controller F3 AIO 8/4 01
  • HIMA HIMax®Relay Module X-D0 12 51
  • HIMA HIMax®Relay Output Module X-DO 12 01
  • HIMA HIMax®Digital Output Module X-DO 32 51
  • HIMA HIMax®Counter Module X-C1 24 51
  • HIMA HIMax®Digital Input Module X-DI 16 01
  • HIMA X-DI 32 52 Digital Input Module
  • HIMA HIMax® Analog input module X-AI 32 01
  • Beckhoff EL1904 | EtherCAT Terminal, 4-channel digital input, 24 V DC, TwinSAFE
  • Beckhoff EL1899 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 10 µs, ground switching
  • Beckhoff ED1897 | EtherCAT Terminal, 32-channel digital input
  • Beckhoff EL1489 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff ED1889 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1889 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1872-0010 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1872 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1862-0010 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1862 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff ED1859 | EtherCAT Terminal, 8-channel digital input
  • Beckhoff EL1859 | EtherCAT Terminal, 8-channel digital input
  • Beckhoff EL1852 | EtherCAT Terminal, 8-channel digital input
  • Beckhoff ED1819 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 10 µs, push-in
  • Kollmorgen S200 Series S20350-VTS SERVO DRIVE
  • Kollmorgen ServoStar CD CR06250 PRD-0030000z-45 , 1.4/2.2KVA Servo Drive Rev M
  • KOLLMORGEN AKD-P02407-NBEC-0000 Servo Drive
  • Kollmorgen ME2-405-B-A2 Goldline Servomotor-Encoder Commutated
  • KOLLMORGEN AKD-P00606-NBCC-I000 SERVO DRIVE
  • Kollmorgen MV65WKS-CE310/22PB Servo Drive Control Module 220v 22a
  • KOLLMORGEN SERVOSTAR 303 S3036 1-SE SERVO DRIVE
  • Kollmorgen S20360-VTS-021 Servo Drive
  • Kollmorgen MMC-SD-1.0-230-D (M.3000.0912) MMC Motion Control
  • Kollmorgen PRD-B040SAIZ-63 SERVO DRIVE CB06550
  • GE PQMII-T20-C-A Power Quality Meter
  • Eaton XV100-BOX-E4-DC1 EasyE4 Nano PLC, Starterset with DC Power supply
  • Eaton EASY-E4-DC-4PE1P easy programmable relays
  • Eaton EASY-E4-AC-12RCX1P easy programmable relays
  • Eaton EASY-E4-AC-12RC1P easy programmable relays
  • Eaton EASY-BOX-E4-UC1 Easy Nano Programmable Logic Controller
  • Eaton EASY-BOX-E4-DC1 Easy Nano Programmable Logic Controller
  • Eaton EASY-BOX-E4-AC1 easy programmable relays
  • Eaton XN-322-18PD-P Power feeder and distribution modules
  • Eaton XN-322-18PD-M Power feeder and distribution modules
  • Eaton XN-322-4PS-20 Power feeder and distribution modules
  • Eaton XN-322-1CNT-8DIO Technology modules
  • Eaton XN-322-1DCD-B35 Technology modules
  • Eaton XN-322-2DMS-WM Technology modules
  • Eaton XN-322-8AIO-U2 Analog input/output module
  • Eaton XN-322-8AO-U2 Analog output module
  • Eaton XN-322-4AI-PTNI Analog input modules
  • Eaton XN-322-10AI-TEKT Analog input module
  • Eaton XN-322-8AI-I Analog input modules
  • Eaton XN-322-7AI-U2PT Analog input modules
  • Eaton XN-322-12DO-P17 Digital output modules
  • Eaton XN-322-16DO-P05 Digital output modules
  • Eaton XN-322-20DI-PCNT Input/output modules
  • Eaton XN-322-20DI-PF Input/output modules
  • Eaton XN-312-GW-CAN Gateway modules
  • Eaton XN-322-20DI-PD Input/output modules
  • Beckhoff EL1814 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 10 µs, 3-wire connection