Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

YOKOGAWA ProSafe-RS N-IO (Network I/O) Safety Instrumented System

From:YOKOGAWA | author:Mr.Chen | Time :2025-12-25 | 401 view: | 🔊 Click to read aloud ❚❚ | Share:

ProSafe-RS R4 adopts the same architecture as CENTUM VP R6 to improve

the engineering environment, thus greatly shortening the project schedule.

ProSafe-RS R4

N-IO (Network I/O): Smart Configurable I/O (SCIO)

In addition to conventional I/O modules dedicated for specific signal types (FIO module), ProSafe-RS R4 can offer the

N-IO module, which handles different signal types at each channel. By concurrently accepting both types of module,

ProSafe-RS R4 can deal more flexibly with a customers plant design requirements.

■ Features

- DI/DO/AI/AO signals can be handled at a single module. The types of I/O signal at each channel can be changed with software.

- Remote installation up to 50 km is available by using optical cables.

- SIL3 can be achieved with single configuration. Redundant configuration is also selectable.

- Terminal block has a disconnect function of signal loop of field devices as a standard function.

- An N-IO baseplate is available for intrinsically safe barriers.

Field Commissioning Support Package (F-CSP): software for validating and configuring N-IO loops

Combined with N-IO modules, F-CSP allows the field devices testing and validation without having a controller and an

engineering station. This software is offered as an option of FieldMate.

Automation Design Suite (AD Suite)

AD Suite offers the engineering environment integrated with CENTUM VP. Its change management function and

other features improve engineering quality and efficiency throughout the plant lifecycle. Based on the customers

design requirements, the engineering environment can be separated, ensuring a flexible configuration.

Benefits of ProSafe-RS R4

Early start-up of a plant

■ Challenge:

Starting up a plant more quickly has long been an issue that directly affects customers’ profits.

■ Our solution:

Application engineering and hardware engineering can progress independently and parallel. This parallel work shortens the

project schedule, either by starting later or by possibly enabling an earlier start-up.

Although the start-up of instruments and the installation of I/O modules can be performed in parallel, the loop check is completed

only after the FAT (Factory Acceptance Test) is finished and the controller and the engineering environment are installed.

In Yokogawas parallel engineering, there is no need to wait for the controller and engineering environment to be completed. The

integrity of loops can be checked only with N-IO modules and F-CSP. If any change is found in the I/O definition information, it can be

corrected on the spot, and the corrected definition can then be reflected in the master information in the plant.

Reducing risks to scheduled project delivery

■ Challenge:

The I/O definition often needs to be changed due to physical constraints. Such problems usually occur during commissioning and

may prolong the project schedule, as well as require costly re-wiring.

■ Our solution:

The I/O definition of N-IO modules can be changed more flexibly. Signal types among DI/DO/AI/AO can be switched only with

software, and there is no need to change I/O modules. Since signal types can be designated at each channel, there is no need to

stock I/O modules for each signal type, reducing maintenance costs.

Highly flexible installation

■ Challenge:

Sufficient space is needed to mount I/O modules. Also, the marshalling to connect field devices and I/O modules require space

and work, increasing costs. This may reduce the number of possible locations for arranging I/O modules.

■ Our solution:

N-IO modules do not need  the hardware marshalling. Conventionally, this marshalling is necessary to arrange field wiring for

each signal type and to connect them to I/O modules dedicated for specific signal types. In contrast, multiple types of signal can

be assigned to a single N-IO module, and there is no need for arranging signal types and thus marshalling. For this reason, N-IO

modules need less space and wiring for installation. This module is ideal for flexible and distributed installation in the field.

Furthermore, the use of N-IO modules eliminates the need for marshalling cabinets, further saving space and costs.

  • HIMA HIMax® HART Communication Module X-HART 32 01
  • HIMA 22121 Output modules
  • HIMA 22120 Output modules
  • HIMA 32110 Relay Amplifier – SIL 4 Certified Safety Module
  • HIMA 32103 Relay Amplifier – SIL 4 Certified Safety Module
  • HIMA 32102 Relay Amplifier – SIL 4 Certified Safety Module
  • HIMA 32102 Relay Amplifier – SIL 4 Certified Safety Module
  • 32100 | HIMA 2 Channel Relay Amplifier
  • HIMA 42500 Selection element,2003 voting Logic function modules
  • HIMA 42400 Blocking element, direct and inverted output Logic function modules
  • HIMA 42300 OR element with 2 inputs Logic function modules
  • HIMA 42200 Element combination AND/OR/blocking element Logic function modules
  • HIMA 42100 AND element with S inputs, 1 with OR Logic function modules
  • HIMA 52100 Time Delay Module
  • HIMA 62100 984162100 2-Fold Analog Limit Monitor
  • HIMA 80110 Reset module
  • HIMA HIMatrix Safety-Related Controller F3 AIO 8/4 01
  • HIMA HIMax®Relay Module X-D0 12 51
  • HIMA HIMax®Relay Output Module X-DO 12 01
  • HIMA HIMax®Digital Output Module X-DO 32 51
  • HIMA HIMax®Counter Module X-C1 24 51
  • HIMA HIMax®Digital Input Module X-DI 16 01
  • HIMA X-DI 32 52 Digital Input Module
  • HIMA HIMax® Analog input module X-AI 32 01
  • Beckhoff EL1904 | EtherCAT Terminal, 4-channel digital input, 24 V DC, TwinSAFE
  • Beckhoff EL1899 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 10 µs, ground switching
  • Beckhoff ED1897 | EtherCAT Terminal, 32-channel digital input
  • Beckhoff EL1489 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff ED1889 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1889 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1872-0010 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1872 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1862-0010 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1862 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff ED1859 | EtherCAT Terminal, 8-channel digital input
  • Beckhoff EL1859 | EtherCAT Terminal, 8-channel digital input
  • Beckhoff EL1852 | EtherCAT Terminal, 8-channel digital input
  • Beckhoff ED1819 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 10 µs, push-in
  • Kollmorgen S200 Series S20350-VTS SERVO DRIVE
  • Kollmorgen ServoStar CD CR06250 PRD-0030000z-45 , 1.4/2.2KVA Servo Drive Rev M
  • KOLLMORGEN AKD-P02407-NBEC-0000 Servo Drive
  • Kollmorgen ME2-405-B-A2 Goldline Servomotor-Encoder Commutated
  • KOLLMORGEN AKD-P00606-NBCC-I000 SERVO DRIVE
  • Kollmorgen MV65WKS-CE310/22PB Servo Drive Control Module 220v 22a
  • KOLLMORGEN SERVOSTAR 303 S3036 1-SE SERVO DRIVE
  • Kollmorgen S20360-VTS-021 Servo Drive
  • Kollmorgen MMC-SD-1.0-230-D (M.3000.0912) MMC Motion Control
  • Kollmorgen PRD-B040SAIZ-63 SERVO DRIVE CB06550
  • GE PQMII-T20-C-A Power Quality Meter
  • Eaton XV100-BOX-E4-DC1 EasyE4 Nano PLC, Starterset with DC Power supply
  • Eaton EASY-E4-DC-4PE1P easy programmable relays
  • Eaton EASY-E4-AC-12RCX1P easy programmable relays
  • Eaton EASY-E4-AC-12RC1P easy programmable relays
  • Eaton EASY-BOX-E4-UC1 Easy Nano Programmable Logic Controller
  • Eaton EASY-BOX-E4-DC1 Easy Nano Programmable Logic Controller
  • Eaton EASY-BOX-E4-AC1 easy programmable relays
  • Eaton XN-322-18PD-P Power feeder and distribution modules
  • Eaton XN-322-18PD-M Power feeder and distribution modules
  • Eaton XN-322-4PS-20 Power feeder and distribution modules
  • Eaton XN-322-1CNT-8DIO Technology modules
  • Eaton XN-322-1DCD-B35 Technology modules
  • Eaton XN-322-2DMS-WM Technology modules
  • Eaton XN-322-8AIO-U2 Analog input/output module
  • Eaton XN-322-8AO-U2 Analog output module
  • Eaton XN-322-4AI-PTNI Analog input modules
  • Eaton XN-322-10AI-TEKT Analog input module
  • Eaton XN-322-8AI-I Analog input modules
  • Eaton XN-322-7AI-U2PT Analog input modules
  • Eaton XN-322-12DO-P17 Digital output modules
  • Eaton XN-322-16DO-P05 Digital output modules
  • Eaton XN-322-20DI-PCNT Input/output modules
  • Eaton XN-322-20DI-PF Input/output modules
  • Eaton XN-312-GW-CAN Gateway modules
  • Eaton XN-322-20DI-PD Input/output modules
  • Beckhoff EL1814 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 10 µs, 3-wire connection
  • Beckhoff EL1819 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 10 µs
  • Beckhoff ED1829 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 3 ms, positive/ground switching, push-in
  • Beckhoff EL1429 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 3 ms
  • Honeywell X-DCS2000-E Digital Integrated System Manager
  • Automotion LC4A00010 DC BL Motor Control, ATS, Sub Assy, SCP, 115VAC
  • 500T-115VAC - VAS ENGINEERING - DORIC 500 SERIES DIGITSL TEMP INDICATOR - MODEL
  • ABB XZ C828 A101 Didt Dioder Snubber 3BHE039453R0101
  • ABB 3BHB027232R0001 1-Phase Charging Transformer
  • ABB 3BHE006412R0101 Circuit Board UFC762AE101
  • ABB XVC770BE101 3BHE021083R0101 Circuit Board
  • ABB 3BHE024747R0101 GD C801 A 3BHE024748 P104 high-voltage board
  • ABB 3BHE021887R0101 UBCC717BE101 Board 3BHB002751R0102
  • ABB 3BHE032593R0001 Isolated Power Supply
  • ABB 3BSC610023R0001 POWER SUPPLY SD812
  • Beckhoff ED1837 | EtherCAT Terminal, 32-channel digital input, 24 V DC, adjustable, push-in
  • Beckhoff EL1417 | EtherCAT Terminal, 32-channel digital input, 24 V DC, adjustable
  • Beckhoff ED1839 | EtherCAT Terminal, 16-channel digital input, 24 V DC, adjustable, push-in
  • Beckhoff EL1409 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 3 ms
  • Beckhoff ED1809 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 3 ms, push-in
  • Beckhoff EL1809 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 3 ms
  • Beckhoff EL1808 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 3 ms, 2-wire connection
  • Beckhoff EL1804 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 3 ms, 3-wire connection
  • Beckhoff EL1722 | EtherCAT Terminal, 2-channel digital input, 120…230 V AC, 10 ms, without power contacts
  • Beckhoff EL1712-0020 | EtherCAT Terminal, 2-channel digital input, 120 V DC, 3 ms
  • Beckhoff EL1712 | EtherCAT Terminal, 2-channel digital input, 120 V AC/DC, 10 ms
  • Beckhoff EL1702-0020 | EtherCAT Terminal, 2-channel digital input, 220 V DC, 3 ms
  • Beckhoff EL1702 | EtherCAT Terminal, 2-channel digital input, 120…230 V AC, 10 ms
  • Beckhoff EL1512 | EtherCAT Terminal, 2-channel digital input, counter, 24 V DC, 1 kHz
  • Beckhoff EL1502 | EtherCAT Terminal, 2-channel digital input, counter, 24 V DC, 100 kHz
  • Beckhoff EL1382 | EtherCAT Terminal, 2-channel digital input, thermistor, 30 ms
  • Beckhoff EL1262-0050 | EtherCAT Terminal, 2-channel digital input, 5 V DC, 1 µs, oversampling
  • Beckhoff EL1262-0010 | EtherCAT Terminal, 2-channel digital input + 2-channel digital output
  • Beckhoff EL1262 | EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs, oversampling
  • Beckhoff EL1259 | EtherCAT Terminal, 8-channel digital input + 8-channel digital output
  • Beckhoff EL1258-0010 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 1 µs, ground switching, multi-timestamp
  • Beckhoff EL1258 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 1 µs, multi-timestamp
  • Beckhoff EL1264 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 1 µs, oversampling
  • Beckhoff EL1254 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 1 µs, timestamp
  • Beckhoff EL1252-0060 | EtherCAT Terminal, 2-channel digital input, 10 V DC, 1 µs, timestamp
  • Beckhoff EL1252-0050 | EtherCAT Terminal, 2-channel digital input, 5 V DC, 1 µs, timestamp
  • Beckhoff EL1252-0010 | EtherCAT Terminal, 2-channel digital input, 24 V DC, 10 µs, timestamp
  • Beckhoff EL1252 | EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs, timestamp
  • Beckhoff EL1202 | EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs
  • Beckhoff EL1144 | EtherCAT Terminal, 4-channel digital input, 12 V DC, 10 µs
  • Beckhoff EL1134 | EtherCAT Terminal, 4-channel digital input, 48 V DC, 10 µs
  • Beckhoff EL1124 | EtherCAT Terminal, 4-channel digital input, 5 V DC, 0.05 µs
  • Beckhoff EL1114 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 10 µs, 2-/3-wire connection
  • Beckhoff EL1104 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 3 ms, 2-/3-wire connection
  • Beckhoff EL1098 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 10 µs, ground switching
  • Beckhoff EL1094 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 10 µs, ground switching
  • Beckhoff EL1088 | EtherCAT Terminal, 8-channel digital input, 24 V DC, 3 ms, ground switching
  • Beckhoff EL1084 | EtherCAT Terminal, 4-channel digital input, 24 V DC, 3 ms, ground switching
  • Beckhoff ELX1058 | EtherCAT Terminal, 8-channel digital input, NAMUR, Ex i