Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

YOKOGAWA ProSafe-RS N-IO (Network I/O) Safety Instrumented System

From:YOKOGAWA | author:Mr.Chen | Time :2025-12-25 | 858 view: | 🔊 Click to read aloud ❚❚ ▶ | Share:

ProSafe-RS R4 adopts the same architecture as CENTUM VP R6 to improve

the engineering environment, thus greatly shortening the project schedule.

ProSafe-RS R4

N-IO (Network I/O): Smart Configurable I/O (SCIO)

In addition to conventional I/O modules dedicated for specific signal types (FIO module), ProSafe-RS R4 can offer the

N-IO module, which handles different signal types at each channel. By concurrently accepting both types of module,

ProSafe-RS R4 can deal more flexibly with a customers plant design requirements.

■ Features

- DI/DO/AI/AO signals can be handled at a single module. The types of I/O signal at each channel can be changed with software.

- Remote installation up to 50 km is available by using optical cables.

- SIL3 can be achieved with single configuration. Redundant configuration is also selectable.

- Terminal block has a disconnect function of signal loop of field devices as a standard function.

- An N-IO baseplate is available for intrinsically safe barriers.

Field Commissioning Support Package (F-CSP): software for validating and configuring N-IO loops

Combined with N-IO modules, F-CSP allows the field devices testing and validation without having a controller and an

engineering station. This software is offered as an option of FieldMate.

Automation Design Suite (AD Suite)

AD Suite offers the engineering environment integrated with CENTUM VP. Its change management function and

other features improve engineering quality and efficiency throughout the plant lifecycle. Based on the customers

design requirements, the engineering environment can be separated, ensuring a flexible configuration.

Benefits of ProSafe-RS R4

Early start-up of a plant

■ Challenge:

Starting up a plant more quickly has long been an issue that directly affects customers’ profits.

■ Our solution:

Application engineering and hardware engineering can progress independently and parallel. This parallel work shortens the

project schedule, either by starting later or by possibly enabling an earlier start-up.

Although the start-up of instruments and the installation of I/O modules can be performed in parallel, the loop check is completed

only after the FAT (Factory Acceptance Test) is finished and the controller and the engineering environment are installed.

In Yokogawas parallel engineering, there is no need to wait for the controller and engineering environment to be completed. The

integrity of loops can be checked only with N-IO modules and F-CSP. If any change is found in the I/O definition information, it can be

corrected on the spot, and the corrected definition can then be reflected in the master information in the plant.

Reducing risks to scheduled project delivery

■ Challenge:

The I/O definition often needs to be changed due to physical constraints. Such problems usually occur during commissioning and

may prolong the project schedule, as well as require costly re-wiring.

■ Our solution:

The I/O definition of N-IO modules can be changed more flexibly. Signal types among DI/DO/AI/AO can be switched only with

software, and there is no need to change I/O modules. Since signal types can be designated at each channel, there is no need to

stock I/O modules for each signal type, reducing maintenance costs.

Highly flexible installation

■ Challenge:

Sufficient space is needed to mount I/O modules. Also, the marshalling to connect field devices and I/O modules require space

and work, increasing costs. This may reduce the number of possible locations for arranging I/O modules.

■ Our solution:

N-IO modules do not need  the hardware marshalling. Conventionally, this marshalling is necessary to arrange field wiring for

each signal type and to connect them to I/O modules dedicated for specific signal types. In contrast, multiple types of signal can

be assigned to a single N-IO module, and there is no need for arranging signal types and thus marshalling. For this reason, N-IO

modules need less space and wiring for installation. This module is ideal for flexible and distributed installation in the field.

Furthermore, the use of N-IO modules eliminates the need for marshalling cabinets, further saving space and costs.

  • Woodward 1751-6058 4 Channel MPU Transformer Module
  • Basler Electric 2D80367G23 DXCB De-Excitation Module 1200V 5000A Excite
  • Basler Electric SSR 63-12-9185900101 Static Voltage Regulator
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EW5MB0N0F
  • Basler Electric MODEL SSR 125-12NF STATIC VOLTAGE REGULATOR 9 1859 00 106
  • Basler Electric Breaker Protection Relay BE1-BPR 9272000315
  • Basler Electric SBO224 Excitation Support System
  • Basler Electric SSR 63-12 Static Voltage Regulator 9 1859 00 101 46534AB
  • Basler Electric AEM-2020 ANALOG EXPANSION MODULE
  • Basler Electric BE 25231-001 Transformer BE25231001
  • Basler Electric PSS-100-Y5 Power Sys Stabilizer dampening oscillations 0.1-5.0Hz
  • Basler Electric BE1-87G-S1A-A1C-A0N0 Variable Percentage Differential Relay
  • Basler Electric SR8A-2B06B3E Static Voltage Regulator SR8A2B06B3E
  • Basler Electric SOLID STATE FREQUENCY CONTROLLER SCP-210 /SCP210 P/No:9095400100
  • Basler Electric BE1-59-A3E-A1J-N1N3F / BE159A3EA1JN1N3F Over Voltage Relay
  • Basler Electric SBO223 Excitation Support System
  • Basler Electric P/N 9 2011 11 100 BRACKET MOUNTED TERMINAL UNIT
  • Basler Electric P/N 9 2011 11 100 BRACKET MOUNTED TERMINAL UNIT
  • Basler Electric voltage regulator P/n: 9 1606 00 101
  • Basler Electric Current Boost System | Model No. CBS-377 P/N 9109600102
  • Basler Electric 8650C72 Exciter Control Module Pcb Board Rev 5
  • Basler Electric 9252000258 Be1-50/51b Overcurrent Relay
  • Basler Electric SR8A-2B01B3A Static Voltage Regulator SR8A2B01B3A
  • Basler Electric SR4A-2B01B3E Static Voltage Regulator SR4A2B01B3E
  • Basler Electric 9017709102 PC Board
  • Basler Electric 9066800102 Excitation Support Systems 9066800-102
  • Beckhoff ELX3152-0090 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELX3158 | EtherCAT Terminal, 8-channel analog input, current, 4…20 mA
  • Beckhoff ELX3152 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3704-1001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0020 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3702-0101 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3702-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3604-0002 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3604-0000 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0032 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0030 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0002 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0000 | EtherCAT Terminal, 2-channel analog input
  • Beckhoff ELM3544-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3542-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • ENOTEC GAS ANALYZER SYSTEM OXITEC 5000 SME-53310000
  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch
  • Eaton 5884-1400 6-Digit Dual Preset Control W/ Batch Control
  • Eaton 1023843 Power Circuit Board 94V
  • EATON ES4P-221-DRXD1 24VDC NSMP
  • Eaton DH222NWK heavy duty fusible safety switch
  • Eaton Touch Panel 10.1 inch XV-303-10-C00-A00-1C
  • Eaton RDF200J-3 Bussmann series RDF fused rotary disconnect switch
  • EATON CORPORATION A200M2CACD A200 NEMA Motor Control
  • Eaton SPD160208Y3J Surge Protection Device
  • EATON CORPORATION SPD160208Y3K SURGE SUPPRESSOR
  • EATON DILM400/22 (RA250) 200KW Coil Voltage/Coil 110-250V 40-60Hz/DC
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • EATON CORPORATION D820MPM HMI
  • EATON PXG900 Power Xpert Insight Gateway 900
  • Eaton Durant 5882-7 Digital Counter loc2D3
  • EATON AXCELIS 1220-0012-0002 DISK VACUUM DI CONTROLLER
  • Eaton 1383B-6501 80 Series Photoelectric Sensor Head
  • Eaton FDC2100L Series C molded case switch
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • Eaton FD3200L circuit breaker
  • Eaton Touch Screen Control Panel X-152-D6-10TVRC-10
  • EATON VICKERS EEA-PAM-523-A-32 02-326001 POWER AMPLIFIER
  • Saacke Seavis HMI 03 EATON XV-102-B6-35TQR-1AL-PLC HMI Touch Panel
  • EATON MTL E05016 DIGITAL INPUT EUROCARD E05516-2134
  • Eaton HFD3150 3P 150A 600VAC Circuit Breaker
  • Eaton HMIVU06CUNB1 HMi Operator Interface, RS-232, 5.6"
  • Cutler-Hammer/ Eaton Panelmate PowerPro 5785 with cables LCD monitor
  • Eaton D100CA40 40 I/O Micro PLC 115VAC Input Triac Output
  • EATON CUTLER HAMMER 66D2032GX1 MP-3000 PROTECTION RELAY
  • EATON R9L3200FJ Rotary Disconnect Switch
  • EATON CORPORATION E51CLT16PCU Switch
  • Aerotech Modular System Control Console
  • Aerotech TV Series Transformers
  • Aerotech TM5 Transformer Module (500 watts)
  • Aerotech TM3 Transformer Module
  • Aerotech UFM Noise Filter Module
  • Aerotech MFM10-2 Motor filter module
  • Aerotech MFM10-1 Motor filter module
  • Aerotech MPG Handwheel Pendant
  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature