Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

YOKOGAWA ProSafe-RS N-IO (Network I/O) Safety Instrumented System

From:YOKOGAWA | author:Mr.Chen | Time :2025-12-25 | 46 view: | Share:

ProSafe-RS R4 adopts the same architecture as CENTUM VP R6 to improve

the engineering environment, thus greatly shortening the project schedule.

ProSafe-RS R4

N-IO (Network I/O): Smart Configurable I/O (SCIO)

In addition to conventional I/O modules dedicated for specific signal types (FIO module), ProSafe-RS R4 can offer the

N-IO module, which handles different signal types at each channel. By concurrently accepting both types of module,

ProSafe-RS R4 can deal more flexibly with a customers plant design requirements.

■ Features

- DI/DO/AI/AO signals can be handled at a single module. The types of I/O signal at each channel can be changed with software.

- Remote installation up to 50 km is available by using optical cables.

- SIL3 can be achieved with single configuration. Redundant configuration is also selectable.

- Terminal block has a disconnect function of signal loop of field devices as a standard function.

- An N-IO baseplate is available for intrinsically safe barriers.

Field Commissioning Support Package (F-CSP): software for validating and configuring N-IO loops

Combined with N-IO modules, F-CSP allows the field devices testing and validation without having a controller and an

engineering station. This software is offered as an option of FieldMate.

Automation Design Suite (AD Suite)

AD Suite offers the engineering environment integrated with CENTUM VP. Its change management function and

other features improve engineering quality and efficiency throughout the plant lifecycle. Based on the customers

design requirements, the engineering environment can be separated, ensuring a flexible configuration.

Benefits of ProSafe-RS R4

Early start-up of a plant

■ Challenge:

Starting up a plant more quickly has long been an issue that directly affects customers’ profits.

■ Our solution:

Application engineering and hardware engineering can progress independently and parallel. This parallel work shortens the

project schedule, either by starting later or by possibly enabling an earlier start-up.

Although the start-up of instruments and the installation of I/O modules can be performed in parallel, the loop check is completed

only after the FAT (Factory Acceptance Test) is finished and the controller and the engineering environment are installed.

In Yokogawas parallel engineering, there is no need to wait for the controller and engineering environment to be completed. The

integrity of loops can be checked only with N-IO modules and F-CSP. If any change is found in the I/O definition information, it can be

corrected on the spot, and the corrected definition can then be reflected in the master information in the plant.

Reducing risks to scheduled project delivery

■ Challenge:

The I/O definition often needs to be changed due to physical constraints. Such problems usually occur during commissioning and

may prolong the project schedule, as well as require costly re-wiring.

■ Our solution:

The I/O definition of N-IO modules can be changed more flexibly. Signal types among DI/DO/AI/AO can be switched only with

software, and there is no need to change I/O modules. Since signal types can be designated at each channel, there is no need to

stock I/O modules for each signal type, reducing maintenance costs.

Highly flexible installation

■ Challenge:

Sufficient space is needed to mount I/O modules. Also, the marshalling to connect field devices and I/O modules require space

and work, increasing costs. This may reduce the number of possible locations for arranging I/O modules.

■ Our solution:

N-IO modules do not need  the hardware marshalling. Conventionally, this marshalling is necessary to arrange field wiring for

each signal type and to connect them to I/O modules dedicated for specific signal types. In contrast, multiple types of signal can

be assigned to a single N-IO module, and there is no need for arranging signal types and thus marshalling. For this reason, N-IO

modules need less space and wiring for installation. This module is ideal for flexible and distributed installation in the field.

Furthermore, the use of N-IO modules eliminates the need for marshalling cabinets, further saving space and costs.

  • Bently TTL70259 LEMO-BNCTTLTach/Keyphasorcable
  • Bently MAGF0104 Accelerometermagneticbase
  • Bently DCCA0041 DCcaradapter
  • Bently CABU0213 USBdatatransfercable
  • Bently ACCL0561 Right-angledaccelerometer
  • Bently ACCL0547 Straightaccelerometer
  • Bently 108M4049-02 SCOUTprogrammedUSBthumbdrive
  • Bently 108M3240 SCOUT140-Exfour-channelportable datacollector
  • Bently 100M5828 SCOUT/Vb Series Hard Case
  • Bently VBMR0222 Stainless safety rings (1 pair)
  • Bently DTC70262 Neoprene dust cover
  • Bently BATT0575 Battery pack ATEX
  • Bently MAGM0064 Accelerometer magnetic base Male connection
  • Bently KTTC0331 Triaxial sensor kit
  • Bently AP3500S2-Z1 Low frequency accelerometer
  • Bently AP3500T2-Z1 Low frequency accelerometer
  • Bently AM3100T2-Z2 General purpose accelerometer
  • Bently AS3100S2-Z2 General purpose accelerometer
  • Bently SUNW0401 Network upgrade
  • Bently CLK20399 Aditional L2 user activation
  • Bently DGLU0219 Dongle for software seat or license mobility
  • Bently 3071/01 System 1 software
  • Bently 108M4069 Laser TachZone 2 rated
  • Bently 108M4067 Arpl15 Oring
  • Bently 108M4066 Circlips-20Mm Stainless
  • Bently 108M4064 Laser Tacho Holder
  • Bently CBBLO026 Carrying casefor the kit
  • Bently CB5R0025 Sensor Cable Five meters, red
  • Bently CB5G0024 Sensor CableFive meters,green
  • Bently MAGA0063 Laser magneticstand
  • Bently CBL50216 Laser cable Five meters
  • Bently 113M5529-01 Reflective tapeOne roll, 60 cm
  • Bently LASA0315 LaserZone 2 rated
  • Bently 110M8172-012 LEMO-BNC TTLTach/Keyphasor cable
  • Bently 108M4045 SCOUT quick start guide
  • Bently PLEU0229 Europe - Category Cpower plug
  • Bently PLHK0245 Hong Kong/UK Category-G power plug
  • Bently PLAU0228 Australia/New Zealand /China - Category Mpower plug
  • Bently PLSAO241 South Africa/India -Category D power plug
  • Bently PLUS0230 USA/Canada - CategoryA power plug
  • Bently 109M2384-01 Neck strap with SensorKeeper
  • Bently MVBX0250 Reference_Guide
  • Bently 113M5585 Accelerometermagnetic base
  • Bently CBVB0032 carrying bag
  • Bently CBTB0278 SCOUT instrument
  • Bently CBCC0027 or138M7748 Triple BNC adapter
  • Bently CABUO213 Transducer cable
  • Bently 110M8172-012 USB data transfer cable
  • Bently CABB0560 BNC to BNC Cable,1meter
  • Bently 108M4044 AC power adapter
  • Bently ACCLO561 or200350* Right-angledaccelerometer or straight accelerometer
  • Bently ACCLO547 or200350* Straight accelerometer
  • Bently 108M3240 SCOUT140Ex four channel portable data collector
  • Eaton F30 Ex ic Adaptor ATEX & IECEx Approved
  • ABB DRIVEMONITOR VERSION 4000 DRIVE MODULE RBOX316-ABB-00
  • ABB VACUUM CONTACTOR VSC7 SCO IEC 60470 400A 3POLE 220-250V 50/60Hz
  • Johnson Controls MS-NAE5512-1 Supports two N2 or two BACnet MS/TP (RS-485) trunks
  • Johnson Controls MS-NAETUNL-8 ToggleTunnel utility for converting an NAE55/NIE55 to an NAE55 model
  • Johnson Controls MS-MECVT-0 MS/TP to Ethernet Converter
  • Johnson Controls MS-SECVT-0 Serial to Ethernet Converter
  • Johnson Controls AS-XFR100-1 Power transformer
  • Johnson Controls AS-XFR100-1 Power transformer
  • Johnson Controls MS-FEC2621-0U FEC26 Field Equipment Controllers
  • Johnson Controls MS-FEC2611-0U FEC26 Field Equipment Controllers
  • Johnson Controls AS-XFR010-1 Power transformer
  • Johnson Controls MS-NAE5521-1 Supports a LONWORKS trunk and two N2 trunks or two BACnet MS/TP (RS-485) trunks
  • Johnson Controls MS-NAE5510-1 NAE55 Network Automation Engines
  • Johnson Controls IOM3731 INSTALLATION MANUAL
  • ALSTOM MCRI1 - MODULE BOARD FOR SETTING SETTINGS AND CURRENT REGULATION
  • ALSTOM BCEA1 - TERMINAL BOARD OF 8 ANALOGUE INPUT SIGNALS
  • ALSTOM E64L1- LOGIC INFORMATION ACQUISITION BOARD
  • ALSTOM BCEL2 - TERMINAL BOARD FOR 12 LOGIC INPUT SIGNALS
  • ALSTOM BCSR1 - TERMINAL BOARD OF 8 LOGIC OUTPUT SIGNALS
  • ALSTOM ESVI1 - INPUT/OUTPUT BOARD FOR CURRENT AND VOLTAGE SIGNALS
  • ALSTOM MDEX1 – EXCITATION CURRENT MEASUREMENT AND CALIBRATION BOARD
  • ALSTOM IRVI20 - REGULATION INTERFACE BOARD
  • ALSTOM RDSP1 – BOARD FOR ADJUSTING DIGITAL SIGNAL PROCESSES
  • ALSTOM ARTN1 - DIGITAL INDICATION BOARD FOR VOLTAGE REGULATION
  • ALSTOM FRTN2 - BOARD OF DIGITAL INDICATION OF VOLTAGE REGULATION
  • ALSTOM CPRM1 - SINGLE-PHASE POWER REGULATION BOARD
  • ALSTOM AMS42 - POWER SUPPLY BOARD
  • DEIF PPM-3 SG PROTECTION AND POWER MANAGEMENT COMPLETE SET
  • DEIF PPM-3 DG Protection and Power Management
  • DEIF S8VK-S48024 Power supplies
  • DEIF S8VK-R20 Redundancy units
  • DEIF S8VK-T96024 Power supplies
  • Deif GPU-3 Generator Protection Unit 0-20MA
  • Deif Du-2 / Mkiii Multil neas Ppm Protecci n Y Gesti n de Energ a 100-690vac
  • DEIF AGC 222 & IOM 220 advanced genset controller
  • Deif Delomatic 4 DGU 0005 Generator Control System PCM 4-1, IOM 4-1, SCM 4-2
  • DEIF PPM-3-DG PROTECTION AND POWER MANAGEMENT MEAS.VOLTAGE:100-690VAC, 0.5MA
  • DEIF AGC Plant Management (Genset Controller) 100132445.10
  • Deif Delomatic 4 DGU 0002 Generator Control System PCM 4-1, IOM 4-1, SCM 4-2
  • DEIF 879.3C Dynamic Wind Sensor with MIC-4224 Display suit Marine
  • DEIF MDR-2 MULTI DIFFERENTIAL PROTECTION RELAY
  • Generator Control Unit Deif Delomatic 4 DGU 0001
  • DEIF DELOMATIC 4 DGU 0001 CONTROLLER
  • DEIF MTR-4-415 1200510024 Multi-transducer
  • Deif DPD 04057 Printed Circuit Board 1044230020F
  • DEIF AGC 252 advanced Genset Controller 2912420010.39 Options -C2-N
  • Deif AGC/GS/3.6 Automatic genset controller 600043767.80
  • Deif GPU/2/GS Generator Protection Unit
  • DEIF AGC-4/GS/4.4 Advanced Genset Controller Option-G5-G7-I1-M12-M13.6-N-J1
  • DEIF PPU-2-GS-100033222.50 PROTECTION AND POWER MANAGEMENT SYSTEM
  • DEIF PPU/2/GS Protection & Paralleling Unit + Operator Panel + Connector cable
  • DEIF PPU-2-GS-100059909.10 WITH DISPLAY AND CABLE PROTECTION
  • DEIF PPU-2-GS 600033613.10 WITH DISPLAY GENERATOR UNIT
  • Deif Delomatic-3 Generator Control Panel System Panel CP-1 | 1044220050D
  • Caterpillar Branded DEIF MCS2 Controller
  • Deif Paralleling & Protection Unit PPU-3 100121906.10 600V
  • A-B 20G11BC1K1JN0NNNNN PowerFlex Air Cooled 755 AC Drive
  • A-B 20P41AF452RA0NNN PowerFlex 452 A DC Drive
  • A-B 20GHAJC540JN0NNNNN PowerFlex Extra Tough 755 AC Drive
  • EPRO MMS6823 9100-00001-05 Displacement Monitor Module
  • GE LP-33 SERIES UPS DISPLAY & CONTROL PANEL LP33
  • GE CL06A300M IEC Contactor (50 Amp)
  • GE CR2962F2D Plugging Switch NIB
  • General Electric IC500A411DG2 Electrical Rectifier Semiconductor
  • GE IS200BICLH1AFE Interface Module 259B2431DB-G01 BICLH1A
  • General Electric 1253-0003-C4 Multilin Analog & I/O Board 369-A200
  • Ge Panametrics Crs-10-Mb Ultrasonic Flow Converter
  • GE PROPRIETARY IS215WEPAH2BB With IS210BPPCH1AD CONTROL BOARD
  • GE MULTILIN / 12P0-0001-P2 / Powerr Supply Board, 870500.DWG, 870501.DWG
  • GENERAL ELECTRIC PL19A129393G4 Auxiliary Receiver in Wall-mount Cabinet
  • GE CR306F002XAAA Nema-4 Coil 115-120V 60Hz 110-50Hz 600Vac Magnetic Contactor
  • General Electric 193x190bag02 ISOL P/S Board I93XI90BAG02 Computer board GE
  • GE Multilin / G6P3CH / Front Panel, G60 Generator Management Relay
  • GE MMY30-R1D26 DewPro MOISTURE TRANSMITTER