Easy to use
Total control. The controller manages all control activities for the I/O interface channels.
It also manages all communication functions for the communications network.
Time tamping, alarming, and trend objects are also managed within the controller.
The controller executes all control strategy with execution speeds up to every 100 ms.
Data protection. Each time you install data in a DeltaV controller, the installation information is automatically saved.
Likewise, when users make online configuration changes to a controller, the system stores these changes as well.
This way, the system always retains a complete record of all the data that has been installed in the controller and any online changes that have been made.
Cold restart. This feature ensures that in case of power failure, the controller will restart without
manual intervention and without any other device present on the network.
Now, you don’t have to reboot from the workstation.
Simply set the restart state of the controller to current conditions.
Note: To prevent process disruption during a short power loss, an uninterruptible power supply (UPS) is available for the controller.
Has the flexibility to meet your needs
Advanced operations. The MD Plus Controller is equipped to handle the DeltaV Batch option, as well as advanced control functions.
You can also use advanced control function such as Neural and Model Predictive Control on the MD Plus controller.
Data pass-through. The controller is equipped with the ability to pass smart HART
information from field devices to any workstation node in the control network.
This means you can take advantage of applications, such as Asset Management Solutions,
that enable you to remotely manage the HART information contained in your HART or FOUNDATION fieldbus-equipped devices.
Prepares you for the future. As your system grows, you can expand your software license
to increase the number of device signal tags (DSTs) allocated to the DeltaV controller.
egin with 50 and expand to 750 DSTs. Control strategy complexity and control module
scan rates determine overall controller performance and application size.
A redundant controller may be added to back up an MD Plus Controller online.
The standby controller comes online automatically, with a bumpless transition.
For more information, refer to the I/O Redundancy product data sheet.
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved