Beckwith Electric M-0067E Tapchanger Control

From:Beckwith Electric | author:Mr.Chen | Time :2026-07-22 | 209 view: | 🔊 Click to read aloud ❚❚ | Share:

General Purpose LTC Transformer Control or Replaces Westinghouse SVC

and SVR Controls

• Adaptable to any LTC Transformer – old or new

• Meets ANSI Class 1 (1%) Accuracy Requirement

• Now in Use by Leading Manufacturers as Standard Equipment

Features

Line Drop Compensation, Non-Sequential and Sequential modes of operation, and manual voltage adjustment

capability is included.

Inputs

Power: A two wire input, requiring less than 3 W at 90 to 140 Vac, provides all power requirements. The unit

should be powered from a potential transformer or from the voltage to be controlled.

Line Current: Line drop compensation is provided by a CT input with a 0.2 A nominal full scale rating. The

burden imposed by this input on the current source is 0.03 VA. A Beckwith Electric model M-0121 (5 A to

0.2 A) or M-0169 (5 A or 8.66 A to 0.2 A) Auxiliary Current Transformer is available when required.

Circulating Current: Parallel operation of transformers is provided by a second CT input with a 0.2 A nominal

full scale rating. The burden imposed by this input on the current source is 0.005 VA. A paralleling input with

a 0.2 A full scale rating gives approximately 24 V correction at approximately 90° for parallel operation with

other transformers.

Front Panel Controls

VOLTAGE CENTER OF BAND: The center of the control band may be set to any voltage from 105 to

135 Vac. The scale calibration accuracy is ± 0.5 V at 120 Vac.

TOTAL BANDWIDTH: The bandwidth control can be adjusted from 1.0 to 6.0 V. The scale calibration

accuracy is ± 0.3 V.

TIME: The timer is adjustable from 0 to 120 seconds, with a scale calibration accuracy of ± 10% of setting or

± 2 seconds, whichever is greater. The timer starts when the voltage goes outside the band and resets within

a few milliseconds upon return to the band or when reset by an external contact in the Non-Sequential mode.

LINE DROP COMPENSATOR: The resistance compensation provides 24 V compensation for 0.2 A input in

phase with the input voltage. The reactance compensation provides 24 V compensation for 0.2 amps input

at a phase angle of ± 90° as chosen by the DIRECT/REVERSE switch. The magnitude and angle of each

circuit is individually set by a pair of trimpots to any accuracy limited only by the instruments used in setting.

The factory setting of magnitude will be within ± 5% and the phase angles within ± 2%. The voltage and two

current circuits are isolated from each other and do not interact.

TEST/OPERATE: When this switch is in the TEST position, the Line Drop Compensator is deactivated and

the voltage may be raised and lowered by means of an uncalibrated voltage control. An external voltmeter

with a burden of 500 Ω per V or higher can be connected to test the band limits by observing when the

RAISE and LOWER LEDs light. No special test voltage source required.

Modes of Operation

Either of the following modes are available as determined by the presence or absence of a cam switch which

is closed while the LTC is in transition.

Non‑Sequential Mode: The timer resets after a tapchange, regardless of voltage.

Sequential Mode: The timer resets only after the sensed voltage is back within the control band.

LED Indicators

The RAISE and LOWER LEDs light to indicate a voltage outside the band and a forthcoming tapchanger

operation as soon as the timer times out. With a slowly varying input, operation of the LEDs and initiation of

timing is very sharp with 0.2 V hysteresis. The LEDs have an expected life of 25 years.

Output Contacts

Two outputs drive a raise and lower motor starter relay. The starters may be any voltage up to 240 Vac. The

output contacts are rated at 2.5 A inrush current and will handle a NEMA size 1 starter or smaller.

Voltage Measurement Accuracy

The unit meets the requirements of accuracy Class 1 as defined in ANSI standards C57.12.30‑1977 paragraph

9.3 and C57.15‑4.2 when tested according to C57.15‑1986 paragraph 9.4.1.

Response Time

M‑0067E Tapchanger Control – Specification

The M‑0067E will respond to 5/8% voltage change in 0.2 seconds, ensuring freedom from hunting on

minimum bandwidth.

Voltage Reduction Options

One‑ or Two‑step Voltage Reduction: Resistors for one or two pre-selected steps of voltage reduction will

  • Beckwith Electric B-2355 Adapter Kit
  • Beckwith Electric B-2203 Adapter Kit
  • Beckwith Electric B-2271 Adapter Kit
  • Beckwith Electric B-2293 Adapter Kit
  • Beckwith Electric B-6200A-U1 Hinge Kit
  • Beckwith Electric M-2032B Battery Charger/Power Supply
  • Beckwith Electric M-2900A Tapchanger Control Cabinet
  • Beckwith Electric M-6200A Digital Voltage Regulator Control
  • Beckwith Electric M-0124 Surface Mounting Adapter
  • Beckwith Electric B-2048 Resistor Assembly
  • Beckwith Electric M0169A Auxiliary Current Transformer Units
  • Beckwith Electric M-0121 and M0169A Auxiliary Current Transformer Units
  • Beckwith Electric M-0404 Voltage Isolation Transformer
  • Beckwith Electric M-0329B LTC Backup Control
  • Beckwith Electric M-0001 Battery Transient Suppressor
  • Beckwith Electric Module d’Équilibrage en Parallèle M-0115A
  • Beckwith Electric M-0115A Parallel Balancing Module
  • Beckwith Electric M-2025D Current Loop Interface Module
  • Beckwith Electric M-0362 Voltage Isolation Transformer
  • Beckwith Electric M-2025B Current Loop Interface Module
  • Beckwith Electric M-2174B Adapter Panel
  • Beckwith Electric M-2027 AC to DC Backup Power Supply
  • Beckwith Electric M-2054 Surface Mount Kit
  • Beckwith Electric M-2067B Adapter Panel
  • Beckwith Electric M-2270B Adapter Panel
  • Beckwith Electric M-2050 Surface Mounting Kit
  • Beckwith Electric M-2230 Adapter Panel
  • Beckwith Electric M-2052 Connection Harness
  • Beckwith Electric M-2051 Connection Harness
  • Beckwith Electric M-2279D Adapter Panel
  • Beckwith Electric M-2053 Adapter Panel
  • Beckwith Electric M-2339 Adapter Panel
  • Beckwith Electric M-2948 Tap Position Sensor
  • Beckwith Electric M-3425A Comprehensive Generator Relay
  • Beckwith Electric M-0193B Syncrocloser® Unit
  • BECKWITH ELECTRIC M-3425A Generator Prothection
  • Beckwith M-3425 Integrated Generator Protection
  • GE XAMP-1-1-2-0-0 XAMP Preamplifer
  • Honeywell 8-Node Enhanced Micro TDC 3000
  • Beckhoff ELM3142-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3104-0030 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3104-0020 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3104-0000 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3102-0120 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3102-0100 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3102-0030 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3102-0000 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3004-0030 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff ELM3004-0000 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff ELM3002-0425 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0405 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0325 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0305 | EtherCAT Terminal, 2-channel analog input, voltage
  • Basler Electric SBO222 Excitation Support System
  • Basler Electric SBO221 Excitation Support System
  • Basler Electric 9488800100 AVC Sensing Module
  • Basler Electric 36T865-2 BE03752001
  • Basler Electric BE1-25 BE1-25/79TR CONTROL SYNC-CHECK RECLOSING RELAY
  • Basler Electric M-300 149D940G02 POWER SUPPLY T159095
  • Basler Electric PCB CONTROL BOARD 9261402111 9346000033 S050105
  • Basler Electric BE 28053-002 Transformer BE28053002
  • Basler Electric BE3-GPR GENERATOR PROTECTIVE RELAY
  • Basler Electric VAR POWER FACTOR CONTROLLER MODEL SCP-250-G-60 P/N 9 1100 00 109
  • Basler Electric BE3-32-1S1N1 Reverse Power Relay - 277v, 5A
  • Basler Electric BE03303001 VOLTAGE TRANSFORMER
  • Basler Electric BE3-GPR-P1BVSF GENERATOR PROTECTIVE RELAY
  • Basler Electric BE1-60 VOLTAGE BALANCE RELAY T176884
  • Basler Electric 9022900-103 6-7VA 60HZ
  • Basler Electric BE1-59-A4E-E1K-B1S3F / BE159A4EE1KB1S3F Over Voltage Relay
  • Basler Electric KR2FF-M Voltage Regulator 9 1163 00 103
  • Basler Electric BE1-81-O/UT3ED1JB6N0F / BE181OUT3ED1JB6N0F
  • Basler Electric PCB Assembly 9059701100 919620
  • Basler Electric SR8A2B01A3E Static Voltace Regulator
  • Basler Electric SSR 63-12 STATIC VOLTAGE REGULATOR 600VAC 50/60HZ 9 1859 00 101
  • Basler Electric Solid State Protective Relay BE1-60
  • Basler Electric BE3-47N/27-3A4N2 9320400101 120V Phase Balance Relay
  • Automatic Voltage Regulators DECS100-B15 For Basler Electric Generator
  • Basler Electric BE1-25/ BE1-25M1GA6PN4R3F STOCK G277 Sync Check Solid State Protective Relay
  • Basler Electric BE25927001 Current Transformer
  • Basler Electric 1783 Be1783 Contactor Dc Current Transformer Coil, 1200:5A Ratio
  • Beckhoff ELM3002-0235 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0225 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0030 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0000 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3783-0100 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3783 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3773 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3751-0024 | EtherCAT Terminal, 1-channel analog input, temperature
  • Beckhoff EL3751-0020 | EtherCAT Terminal, 1-channel analog input, multi-function
  • Beckhoff EL3751-0004 | EtherCAT Terminal, 1-channel analog input, temperature
  • Beckhoff EL3751 | EtherCAT Terminal, 1-channel analog input, multi-function
  • Beckhoff EL3742 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff EL3702-0015 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3702 | EtherCAT Terminal, 2-channel analog input, voltage
  • CTI 2500S-27-1550 Slice I/O, RS232/485, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1550 Slice I/O, RS232/485, 8DIO / 2UAI
  • CTI 2500S-23-1550 Slice I/O, RS232/485, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500-RIO-A RS485 Remote Base Controller
  • CTI 2515-A 100-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2515 100-Watt AC Power Supply (MATURE - replaced by 2515-A)
  • CTI 2513-A 75-Watt DC Power Supply with Redundancy Support
  • CTI 2513 75-Watt 24VDC Power Supply
  • CTI 2512-A 75-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2512 75-Watt AC/DC Power Supply
  • CTI 2510 125 VDC Power Supply (MATURE - Replaced by 2512)
  • CTI 2559-FCAL Precision Calibration Connector
  • CTI 2596 8/16-Point DC Output Module
  • CTI 2589-A 8/16/32-Point Universal Discrete Input Module
  • CTI 2588-8 8-Point Universal Discrete Input Module (MATURED - replaced by 2589-B)
  • CTI 2585 16-Point TTL/Word Input Module
  • CTI 2582 16-Point Isolated 125 VDC Input Module
  • CTI 2581 16-Point Isolated 12-56 VDC Input Module
  • CTI 2580 16-Point Isolated 95-132 VAC Input Module
  • Basler Electric Model KT3B Voltage Regulator 2920-00-300-9212, 90 24700 101
  • Basler Electric BE1-67 Ground Directional Overcurrent Protective Relay
  • Basler Electric BE1810/U-2 Solid State Frequency Relay BE1810
  • Basler Electric 9105100106 UFOV-250A Under Freq./Overvoltage Protector
  • Basler Electric 9289902106 Circuit Board Rev A
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K2EW7MA1N0F
  • Basler Electric BE3-49R-5I5A1 9320500101 TEMPERATURE RELAY
  • Basler Electric BE1-51-K1E-Z1P-A0N0F / BE151K1EZ1PA0N0F Time Overcurrent Relay
  • Basler Electric 9121000106 MANUAL VOLTAGE CONTROL
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50-51B-106
  • Basler Electric STATIC VOLTAGE REGULATOR SR32A-2B15B3E
  • Basler Electric BE1-51A-K2E-W7M-B1N1A SOLID STATE TIME OVERCURRENT RELAY
  • Basler Electric SR4A2B06B3A STATIC VOLTAGE REGULATOR SR4A
  • Basler Electric 801A193F02 Hammond