The GE Multilin 745-W2-P15-G1-Lo-A-R Transformer Protection System can monitor and respond to physical and electronic variables like temperature, harmonics, and overexcitation. The system extends system life through its protective capabilities and efficient management of transformer systems.

Product Description

The 745-W2-P15-G1-LO-A-R is a transformer management relay produced by GE Multilin and protects transformer systems by monitoring and responding to physical and electronic variables, such as harmonics, overexcitation, temperature, and currents.The 745 is able to adapt to shifting conditions within the transformer system, taking necessary steps to alleviate strain. It is able to protect and manage transformer systems small, medium, and large. Users can establish setpoints (analogous to settings) that help determine how the relay manages and protects the system. Setpoints can be easily saved and loaded from file using a computer running EnerVista 745 connected to the device’s RS232 port.

The body of the device itself is divided up into approximately four sections, which includes the display, status indicators, keypad, and RS232 interface. The display is a forty character LCD which is capable of displaying screens needed to assign and edit setpoints. The liquid crystal display also can indicate errors as they emerge, especially in response to incorrect keypad entry. The liquid crystal display can also passively read off different system values when not in active use, and users can edit the relay’s settings to shift what appears during the idle process. In addition to the LCD, a number of LEDs located at the front of the case provide insight into system functionality, indicating if issues such as self-test errors or transformer overloads occur. The keypad can be used to manually adjust setpoints, and the RS232 port can connect computers running the EnerVista 745 software to the 745 relay itself, which allows for quicker and easier programmability.

Frequently Asked Questions about 745-W2-P15-G1-LO-A-R

What is the FlexLogic feature included with the General Electric Multilin 745-W2-P15-G1-Lo-A-R Transformer Protection System?

The FlexLogic of the 745-W2-P15-G1-Lo-A-R Transformer Protection System allows the unit to compute PLC equations by using logical inputs and protection elements that can be adapted to any output.

What options does the General Electric Multilin 745-W2-P15-G1-Lo-A-R Transformer Protection System have?

The General Electric Multilin 745-W2-P15-G1-Lo-A-R Transformer Protection System has the A and the R options which indicate analog inputs and outputs and a restricted ground fault.

What testing capabilities does the GE Multilin 745-W2-P15-G1-Lo-A-R have?

The Multilin 745-W2-P15-G1-Lo-A-R has features that make it a great transformer protection system. It has simulation and testing features so that the operator can test the relay operation  by looking at either waveform data that is captured in the field or that is generated by a computer. This waveform data is then digitized and can be played back. Waveform data can also be recorded to look at fault, alarm, or inrush situations and conditions.

Can you tell me more about the restricted ground fault element for the General Electric Multilin 745-W2-P15-G1-Lo-A-R Transformer Protection System?

The restricted ground fault element for the General Electric Multilin 745-W2-P15-G1-Lo-A-R Transformer Protection System includes two elements with a dropout level of 97 to 98% of puckup. The minumum pickup is generally 0.02 to 20.000 x CT which makes this option a great inclusion in the transformer protection system.

Related Product Recommendations:

1769-L30ER Dual Ethernet Controller Device

1756-IF4FXOF2F ControlLogix Discrete High-Speed Analog I/O Module

IC660TBD024K GeniusI/O Terminal Assembly Module

1769-OF2 Analog Output Module

IC200MDL140 Discrete Input Module

IC200ALG327H 12-Channel 13-Bit Voltage Analog Output Module

HE693THM884M Thermocouple Input Module

2711-M3A19L1 Operator Terminal Human Machine Interface

1746-NT8 SLC 500 Thermocouple/Voltage Analog Input Module

  • GE IS420ESWAH5A Mark VIe IONet Switch
  • GE IS420ESWAH4A Mark VIe IONet Switch
  • GE IS420ESWAH2A Mark VIe IONet Switch
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51M, Self-Powered Time Overcurrent Relay
  • Basler Electric BE1-50/51B, Self-Powered Time Overcurrent Relay
  • Basler Electric BE1-11m, Motor Protection System
  • Basler Electric BE1-11t, Transformer Protection System
  • Basler Electric BE1-11d, DC Power Protection System
  • Basler Electric BE1-11i, Intertie Protection System
  • Basler Electric BE1-11g, Generator Protection System
  • Basler Electric BE1-11f, Feeder Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES-25, Sync-Check Relay
  • Basler Electric ES-27, Undervoltage Relay
  • Basler Electric ES-27/59, Under/Overvoltage Relay
  • Basler Electric ES-32, Reverse Power Relay
  • Basler Electric ES-37, Undercurrent Relay
  • Basler Electric ES-37/51, Under/Overcurrent Relay
  • Basler Electric ES-47, Phase Sequence Relay
  • Basler Electric ES-47N, Phase Balance Relay
  • Basler Electric ES-47N/27, Phase Balance/Undervoltage Relay
  • Basler Electric ES-49, Temperature Relay
  • Basler Electric ES-51, Overcurrent Relay
  • Basler Electric ES-55, Power Factor Relay
  • Basler Electric ES-59, Overvoltage Relay
  • Basler Electric ES-74V, DC Voltage Sensing Relay
  • Basler Electric ES-81O, Overfrequency Relay
  • Basler Electric ES-81O/U, Over/Underfrequency Relay
  • Basler Electric ES-81U, Underfrequency Relay
  • Basler Electric DECS-250-CN1SN1N Digital Excitation Control System
  • Beckhoff EL2622-0010 EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2622 | EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2612 | EtherCAT Terminal, 2-channel relay output, 125 V AC, 30 V DC, 0.5 A AC, 2 A DC
  • Beckhoff EL2602-0010 EtherCAT Terminal, 2-channel relay output
  • Beckhoff EL2602 | EtherCAT Terminal, 2-channel relay output, 230 V AC, 30 V DC, 5 A
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2574 | EtherCAT Terminal, 4-channel LED output, pixel LED
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output
  • Beckhoff EL2535-0100 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2535-0050 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output
  • KEBA KEVIEW V2 341/C-4400 HMI TOUCHSCREEN UNIT
  • KEBA KEMRO K2-200 BL250/A BL 250/A Bus Coupler Module
  • Keba E-CON-14 Operator Interface Panel
  • KEBA CP 255/W Plc Module
  • KEBA CU 212 ZENTRALBAUGRUPPE
  • KEBA CU211/0 25817 Ind 06
  • KEBA RS 091 POWER SUPPLY MODULE
  • KEBA E-SP-CCEC/22180 Panel
  • KEBA E-CPU-186B Control Circuit Board D1633C
  • Keba Kemro K2-200 Control CP 255/X, Part. 072076
  • KEBA analog module, AR281, AR 281
  • KEBA BL250/B Bus link module
  • KEBA Kemro K2-400, DO 470/A, Part No. 054945
  • KEBA HAITAN SA900 Operator Panel
  • KEBA DO 321 module DO 321/B
  • KEBA KeTop C20t-t00-Ar0-KMT Tech Pendant by Karl Mayer
  • KEBA HT401/BENNINGER/5M/55268 TEACH PENDANT HT401BENNINGER/5M/55268
  • KEBA AR 281 ANALOGE INPUT BOARD
  • Engel Keba EC100 PLC Rack with PS244 CU211 PD242 AR181 TT081 DO321 DI325 (19821)
  • KEBA CU 313 Central Unit CU 313/C-SI/63036 Card 128MB
  • KEBA TM-240/A PLC MODULE
  • Keba D1633C E-Cpu-186B Cpu Control Circuit Board W/ D1630D
  • Keba Engel E-CON-CC100/A/22178 HMI Operator Control Display Panel
  • KEBA K2-200 CP 242/B controller module
  • KEBA KEVIEW V2 341/C-4400 HMI TOUCHSCREEN UNIT 84494 24 VDC
  • KEBA E-8-THERMO 1770B-1 Thermocouple circuit board
  • KEBA 3HAC12929-1 TEACH PENDANT
  • Keba KETOP C50 R/73810/06 KEBA PANEL OPERATOR DISPLAY
  • KEBA Kemro K2-400 DO 470/B 059707 Module
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Beckhoff EL2502-0010 | EtherCAT Terminal, 2-channel PWM output
  • Beckhoff EL2502 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 0.5 A
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protectio
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • SAACKE FSC-01V3.02/V3.00 Industrial Combustion Controller
  • GE Multilin 750-P5-G5-S5-HI-A20-G 750 Management Relay
  • GE Multilin 750-P5-G5-D5-HI-A20-R 750/760 Feeder Mgmt Relay Series
  • GE Multilin 750-P5-G5-D5-HI-A20-G Management Relay
  • GE Multilin 750-P5-G1-D5-HI-A20-R Multilin 1A Zero Sequence Current Inputs
  • GE Multilin 750-P1-G1-S1-HI-A20-R-T-H Feeder Management Relays
  • GE Multilin 750-P1-G1-S1-HI-A20-R Feeder Management Relays
  • GE Multilin 750-P1-G1-D1-HI-A20-R Base Unit 750 Relay
  • GE Multilin 239-RTD-AN-H motor protection relay
  • GE Multilin 489-P5-HI-A20-T-H Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-T Generator Management Relay for 489 Series
  • GE Multilin 489-P5-HI-A20-E-H Relay Motor Management
  • GE Multilin 489-P1-LO-A20 489 Motor Management Relay Base Unit
  • GE Multilin SR469-P5-LO-A20-T Motor Management Relay
  • GE Relay from GE Grid Solutions SR469-P5-LO-A20-E
  • GE Multilin SR469-P5-LO-A20 Motor Management Relay with Case
  • GE Multilin SR469-P5-HI-A20-T 469 Series Relay
  • GE Multilin SR469-P1-HI-A1-E-H 469 Series Relay
  • GE Multilin SR469-P1-H1-A1-E 469 Series Relay
  • GE Multilin 469-P5-LO-A20-T Phase Current Input 5 A Phase CT Secondaries
  • GE Multilin 469-P5-LO-A20-E LO Control Power with 4-20mA Analog Outputs
  • GE Multilin 469-P5-LO-A20 Motor Management Relay
  • GE Multilin 469-P5-HI-A20-E-H Motor Management Relay
  • GE Multilin 469-P5-HI-A20 469 Motor Management Relay