The Full Current Output Option Relay 139-H-FLC is a horizontal mounting specialty model.

This model has an external reset switch that works in conjunction with the front panel reset switch.

This model also has an emergency restart option.

Product Description

Model 139-H-FLC is a full load current horizontal mount motor protection relay.

This model has a full load current of 4 to 20 milliamps. Associated protections listed for this relay include overheating, stall-mechanical blocking,

Rotor Lockout, Undercurrent, Ground Fault, Single Phase/Unbalance, Repeat Start, and Overload Protection with selectable curves.

This relay will protect three-phase AC motors from environmental influences that can cause damage.

The 139-H-FLC relay will be used in six applications; one of the applications is to ensure user safety.

This application will utilize the ground fault function to find leakage currents caused by moisture or potential winding shorts in mines, thus preventing shock hazards.

As mentioned above, the relay will be mounted horizontally; it should be noted that a rectangular panel cutout is required for whichever mounting orientation is chosen for the relay.

Once the current breaker is available, the relay will be held in place by two U-clips and then prepared for wiring.

The 139-H-FLC relay can be supplied with ground fault current and it will accept all current carrying conductors through the ground fault current window.

Please note that it is highly recommended that at least two current leads need to be wound together to minimize noise pickup on the relay.

There is a specially designed current that can be used to help output lower level signals.

Frequently Asked Questions about the 139-H-FLC

What is the memory capability of the 139-H-FLC multi-wire general purpose motor protection relay?

This 139-H-FLC is designed to electronically record up to 30 minutes of memory to simulate heat buildup in a motor.

If no overload occurs during this 30 minute period, the memory will be refreshed.

However, if an overload occurs or the motor starts, the circuitry remembers these conditions and can reduce the amount of time available for future overload conditions.

If the motor enters a trip condition due to overheating, the relay will latch to restart for at least 30 minutes to allow the motor to cool.

Motor start trip conditions and overload conditions may cause the motor to heat up, hence the 30 minute lockout time.

Blocked-Rapid Trip, Short Circuit, Unbalance, or Ground Fault conditions do not cause heating and enable the turntable to perform an immediate system reset.

Can users customize the 139-H-FLC Multi-Wire Universal Motor Protection Relay for specific motors?

Users can select from 15 different operating profiles for the 139-H-FLC Multi-Wire Universal Motor Protection Relay.

Four switches are used to select the desired operating profile. The user can find the manufacturer's data for the motor

Plot the data on the run curve to customize the 139-H-FLC to the motor that needs to be protected.

The full load current from terminals one and two on this model will be proportional to the percentage of full motor current.

Current levels will not be affected by any different wiring lengths.

Related Product Recommendations:

IC660TBD024K Genius I/O Terminal Assembly Module

IC687BEM713B Fanuc 90-70 Series Bus Transmitter Unit

DS200KLDBG1ABC DS215KLDBG1AZZ03A Automation Module

IC698PSA100 Fanuc RX7i Series Central Processor

IC698PSA350D Fanuc RX7i Series Central Processor

44A751101-G01 Processor Module

8115-DO-DC 8-Channel Digital Output Module

DeltaVrm VerticalPlus Input/Output Subsystem carrier

FBM203 P0914SV Channel Isolated 8-Input RTD

FBM204 P0914SYI/O Module 4 Channel

369-HI-R-M-F-E-H-E Motor Management Relay

369-C101 Motor Management Relay

369-LO-0-M-F-E-0-0 Motor Management Relay

  • Basler Electric BE1-67 / BE167 DIRECTIONAL OVERCURRENT RELAY
  • Basler Electric BE1-25/79TR Reclosing Relay BE1 25 79TR
  • Basler Electric Contact Expansion Module CEM-2020
  • Basler Electric MVC-300 MANUAL VOLTAGE CONTROL UNIT 9121000106
  • Basler Electric KR2FF Voltage Regulator 9 1163 00 109
  • Basler Electric BE1-81O/UT3EE1YA9S0F / BE181OUT3EE1YA9S0F
  • Basler Electric BE1-87G-G1E-A1K-A0N0F / BE187GG1EA1KA0N0F
  • Basler Electric BE1-47NE3EA1PA0N2F / BE147NE3EA1PA0N2F
  • Basler Electric BE1-81-T1E-E1C-B0N1F / BE181T1EE1CB0N1F
  • Basler Electric BE1-25 SYNC-CHECK RELAY M1E A7P A5N3F
  • Basler Electric BE1-40Q Solid State Protective Relay/ Loss Of Excitation Relay
  • Basler Electric OVERCURRENT RELAY, BE1-50/51M-104
  • Basler Electric MVC 232 MANUAL VOLTAGE CONTROL 9037000103
  • Basler Electric SSE-N 250-9 KW Shunt Static Exciter-Regulator
  • Basler Electric, Solid State Protective Relay, BE1-60
  • Basler Electric SR4A-2B15B3A Static Voltage Regulator 120vac Includes U6250MKG1L
  • Basler Electric BE1-50BF Breaker Failure Relay
  • Basler Electric BE1A1HF1JD1S2F / BE1A1HF1JD1S2F
  • Basler Electric BE1-81O/UT3EE1JA7N2F / BE181OUT3EE1JA7N2F
  • Basler Electric EXCITER DIODE MONITOR EDM-200
  • Basler Electric DECS125-15-B2C5 DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric OVER CURRENT RELAY 9252000107
  • Eaton Sag Ride-Through power conditioner
  • Eaton Sag Ride-Through power conditioner
  • Eaton Power-Sure 800
  • Eaton Power-Sure 700
  • Eaton Power-Suppress 600
  • Eaton T100H-2500-5HC PWR SUPPRESS T100 HW 2.5KVA, 50 HZ, 55DEG C MAX
  • Eaton T100H-1800 PWR SUPPRESS T100 HW 1.8KVA
  • Eaton 9468-ET IS Ethernet Isolator
  • Eaton 9466-ETA IS Ethernet Managed Switch
  • Eaton 9466-ET IS Ethernet Managed Switch
  • Eaton 9465-ETA-S-SC IS Media Converter Single-mode
  • Eaton 9465-ET-M-ST IS Media Converter Multimode
  • Eaton 9465-ET-S-SC IS Media Converter Single-mode
  • Eaton 9465-ET-M-SC IS Media Converter Multimode
  • Eaton 9461-ET IS Serial to Ethernet Gateway
  • Beckwith Electric M-0067E Tapchanger Control
  • Beckwith Electric M-2001D Digital Tapchanger Control
  • Beckwith Electric M-2001C Digital Tapchanger Control
  • Beckwith Electric B-1500 Battery Backup Power
  • Beckwith Electric B-2083 SmartBank Three Phase Junction Box
  • Beckwith Electric M-2017 Capacitor Bank Discharge Tool
  • Beckwith Electric M-2980A Weatherproof Capacitor Control Cabinet
  • Beckwith Electric M-6283A Three Phase Digital Capacitor Bank Control
  • Beckwith Electric M-6280A Digital Capacitor Bank Control
  • Beckwith Electric M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-3420 Generator Protection Relay
  • Beckwith Electric M‑0193B Syncrocloser® Unit
  • Beckwith Electric M-3520 Intertie Protection Relay
  • Basler Electric BE1-25 Sync-check Protective Relay
  • Basler Electric RDP-110 REMOTE DISPLAY PANEL
  • Basler Electric SSR 125-12 VOLTAGE REGULATOR 9185900102 WITH MODULE 9261500101
  • Basler Electric BE1-851 OVERCURRENT PROTECTION RELAY MECHANISM G3A1S1N
  • Basler Electric 149D930G02 / 149D930G02
  • Basler Electric BE1-81O/UT3EE1LB7S1F / BE181OUT3EE1LB7S1F Digital Frequency Relay
  • Basler Electric BE1-51/27CA1EZ10A0N0F / BE15127CA1EZ10A0N0F Time Overcurrent Relay
  • Basler Electric 149D956G02 / 149D956G02
  • Basler Electric BE1-51A / BE151A Overcurrent Relay
  • Basler Electric BE1-40Q-F3E-E10-A0N0F / BE140QF3EE10A0N0F
  • Basler Electric RDP-110-S1 Generator Annuciator
  • Basler Electric DECS-300 DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric - DECS-200-1C - Digital Excitation Control System
  • Basler Electric DECS125-15 Digital Excitation Control System with Power Module
  • Basler Electric BE1-87G Variable Percentage Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric / Kohler BE1-11g Generator Protection Relay G5A3M2J2N0E000
  • Basler Electric BE1-81O/UT3ED1JA7N2F / BE181OUT3ED1JA7N2F
  • Basler Electric BE1-81O/UT3EE1YB7N1F / BE181OUT3EE1YB7N1F
  • Basler Electric DECS-200 -1L DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric DECS 125-15-B2C1 V.2.0.9 DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric 9507900205 SSR Retrofit Static Voltage Regulator
  • Basler Electric BE2000E Digital Volatge Regulator
  • BASLER DECS-250-CN1CN1N DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric DGC-2020 Digital Genset Generator Controller Panel Enclosure
  • Basler Electric BE1-81O/UT3ED1LA7N0F / BE181OUT3ED1LA7N0F
  • Basler Electric BE1-81O/UT3EE1YA9S0F / BE181OUT3EE1YA9S0F
  • Basler Electric BE1-81O/UT3EE1YA6N1F / BE181OUT3EE1YA6N1F
  • Basler Electric DECS125-15 DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric BE1-951 OverCurrent Protect System
  • Basler Electric BE1-700V Digital Protective Relay N3N2X1N
  • APR63-5 Basler Electric Automatic Voltage Regulator
  • Basler BE1-851 overcurrent relay
  • Basler Electric BE1-87T Transformer Differential Relay Module
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler Electric 9310300100 DECS-300 Digital Excitation Control System
  • Basler Electric SSE-N 125-4.5KW SHUNT EXCITER REGULATOR
  • Basler Electric DGC-2020HD-5NS1DNSBA Digital Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F / BE181OUT3EE1JB7N1F
  • Basler Electric BE1-81T1EE1WA0N1F / BE181T1EE1WA0N1F
  • Basler Electric BE1-25M1EA6PN5R1F / BE125M1EA6PN5R1F
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric DECS-250 - CN2CN 1N Digital Excitation Control System Unit
  • Basler Electric Relay BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 DIGITAL EXCITATION CONTROL SYSTEM
  • DECS-200-1C Digital Excitation Control System
  • Basler Electric DECS-200N-C1 Negative Forcing Digital Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250 DIGITAL EXCITATION CONTROL SYSTEM DECS-250-LN1CN1N
  • Basler Electric DECS-250 LN2SA1D Digital Excitation Control System Unit
  • Basler Electric BE1-87T-A1E-A1J-D0S1F / BE187TA1EA1JD0S1F
  • Basler Electric BE1-11-G6D1M0J2P0E000 / BE111G6D1M0J2P0E000
  • Basler Electric BE1-GPS100-E4N1H1N / BE1GPS100E4N1H1N
  • Eaton Omnex T300-000272 T300 Series Remote Controller
  • EATON ELPRO 450U-E Wireless Ethernet Modem Model: 450U-E-L-440-W
  • Eaton JD3225 Series C complete molded case circuit breaker
  • Eaton HMP-HM64 Crouse-Hinds series MTL HART backplane
  • EATON VICKERS EEA-PAM-523-A-32 02-326001 POWER AMPLIFIER
  • Eaton HTP-SC16M / MTL Hart Multiplexor Connection Unit
  • Eaton XV-152-D6-10TVR-10 150609 Touch Panel
  • Eaton S801+ soft starter S801+N66N3S-MA
  • Eaton Series C complete molded case circuit breaker EHD3015L
  • Eaton V200M4CJC NEMA starter, Space SVG reversing starter
  • EATON CORPORATION CAN-16DI/P / CAN16DIP
  • Eaton Soft Starter S801+N66N3S
  • Eaton Soft Starter S801+N66N3S
  • Eaton XV-303-70-B00-A00-1B Base HMI XV300 Single Ethernet
  • EATON XV-303-70-B00-A00S07 / XV-303-70-B00-A00S07
  • EATON CUTLER-HAMMER MP-3010 SAFETY RELAY 66D2205G01 MP-3000
  • EATON CUTLER HAMMER 92-02123-00 7600C OPERATOR INTERFACE PANELMATE BLIND NODE EP
  • EATON CORPORATION HMCP150T4CBP10 CIRCUIT BREAKER
  • Eaton 142531 XV-102-D6-57TVR-10 Touch Panel
  • EATON ELECTRIC CAN-16DO/0.5A-PK 140254 CanOpen digital output 0.5A
  • EATON XV-102-B5-35TQR-10-PLC 140021 XV102B535TQR10PLC
  • EATON MP-3000 66D2032GX1 NSNP
  • Eaton HFD3150 3P 150A 600VAC Circuit Breaker