Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

FOXBORO E69F Field Mount Current Pneumatic Signal Converter

From:FOXBORO | author:Mr.Chen | Time :2024-07-08 | 172 view: | Share:

The E69F Field Mount Current Pneumatic Signal Converter accepts a standard DC input signal and converts it to a proportional pneumatic output signal for use with other pneumatic instruments or control valves.

and converts it to a proportional pneumatic output signal for use with other pneumatic instruments or control valves.

As indicated by the "CE" marking on the product, it complies with applicable European Union directives.

Compact and easy to install

The small size and compact design of the E69F converter allows for easy connection to electrical and pneumatic interfaces.

It can be easily mounted on a surface, on a valve yoke or on a vertical pipe with a nominal DN 50 or 2.

Minimal influence on ambient atmospheric conditions

The design of the corona motor in the E69F converter allows a large clearance between the coil and the housing.

Normal atmospheric variations may cause corrosion and dust particles, but will not impede the operation of the mechanism as would be the case with voice coil type instruments.

Wide range of applications

Selectable input and output signals, different input ranges, and direct or reverse action make this converter easily adaptable to a wide variety of applications.

The choice of output signals makes the converter particularly suitable for valve applications.

PERFORMANCE SPECIFICATIONS Performance Specifications

Accuracy

±1.0% for Output Signal Codes 2 and 3 ranges

Output signal codes 7 and 8 ±2% of range

Linearity ±0.5% of range, typical

(Maximum deviation limited by accuracy specifications Maximum deviation limited by accuracy specifications)

Repeatability ±0.25% of range, typical

(maximum deviation limited by accuracy specifications maximum deviation limited by accuracy specifications)

Hysteresis ±0.5% of range, typical

(Maximum deviation is limited by accuracy specifications Maximum deviation is limited by accuracy specifications)

Deadband 0.1 % of range

Air Supply Pressure Effect

Zero shift due to changes in air supply pressure is less than 0.04% per kPa (0.25% per psi).

Ambient Temperature Effects

Over an operating temperature range of 0 to 60°C (32 to 140°F), a change in ambient temperature of 28°C (50°F) will result in a zero and range shift of ±1.0% or less.

Tilt Effect

A 5-degree change in inclination from the vertical results in a maximum zero shift of 0.25% of range. This error can be eliminated by calibrating the instrument at the intended mounting position.

Shock Effect

The maximum zero offset is 0.5% of the range for a 300 m/s2 (30 "g") shock test on a feedback support frame.

  • GE IS230TNRLH1B Relay Output DINrail Module
  • GE IS220PAICH1B Analog I/O Module
  • GE IS220PAICH1B Analog I/O Module
  • GE IS230TNAIH2C - Analog I/O DIN RAIL Module
  • ABB DAPU100 3ASC25H204 Control board I/O
  • Kongsberg RCU502I 421768 Remote Control Unit (Modular I/O Processor)
  • ABB AC 800PEC PC D237 3BHE028915R0101 / PC D237 A101 CONTROLLER BOARD
  • ABB GVC704AE01 5SHX1060H0001 3BHB003230R0101 Medium voltage inverter
  • ABB Process Panel PP245 3BSC690126R2 PP245B
  • GE Mark VIe & VIeS IS230PCAAH1B - Core Analog I/O Module
  • GE Mark VIe & VIeS IS230PCAAH1A Core Analog I/O Module
  • Emerson PMCSPANA/IH PMC Carrier Installation and Use Manual
  • Emerson PMCSPAN26E-010 Secondary PMC expansion
  • Emerson PMCSPAN26E-002 Primary PMC expansion
  • Emerson PMCSPAN16E-010 Secondary PCI expansion
  • Emerson PMCSPAN16E-002 Primary PCI expansion
  • A-B 1783-HMS4C4CGN Stratix 5400 Ethernet Managed Switches
  • A-B 1783-RA5TGC4G Stratix 4300 Remote Access Routers
  • A-B 1783-CMS10DP Stratix 5200 Ethernet Managed Switches
  • A-B 1783-CMS20DP Stratix 5200 Ethernet Managed Switches
  • A-B 1783-CMS20DP Stratix 5200 Ethernet Managed Switches
  • A-B 1783-HMS8S4CGN Stratix 5400 Ethernet Managed Switches
  • A-B 1783-CMS6B Stratix 5200 Ethernet Managed Switches
  • A-B 1783-RA5TGW Stratix 4300 Remote Access Routers
  • A-B 1783-RA2TGWC4G Stratix 4300 Remote Access Routers
  • A-B 1783-US8T/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US5TG/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-RA2TGW Stratix 4300 Remote Access Routers
  • A-B 1783-US8T/A Stratix 2000 Ethernet Unmanaged Switches—Series A
  • A-B 1783-US6T2F/A Stratix 2000 Ethernet Unmanaged Switches—Series A
  • A-B 1783-US4T1F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US5TG Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US4T1H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2TG2H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US5T/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US6T2TG2F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2H/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US4T1H/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US14T2S Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US7T1H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US16T2S Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-RA2TGC4G Stratix 4300 Remote Access Routers
  • A-B 1783-US16T/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US7T1F/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-RA2TGB Stratix 4300 Remote Access Routers
  • A-B 1783-LMS5 Stratix 2500 Ethernet Lightly Managed Switches
  • A-B 1783-US7T1F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US4T1F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US16T Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US8T Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2H/A Stratix 2000 Ethernet Unmanaged Switches—Series A
  • A-B 1783-US4T1F/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US8TG2GX Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US5T 5 Port Unmanaged Switch
  • MOOG D138-002-002 Industrial Control Module
  • MOOG D138-003-001 Industrial Control Module
  • MOOG CA98502-001 Accessories for Ruggedized Motion Controller
  • MOOG D691-078D servo valve
  • MOOG CA65866-001 MSD Motion Controller
  • MOOG C43148-001 QD10 16/16 Digital l/0 module
  • MOOG D138-002-012 Main control unit
  • MOOG CA94286-001 Accessories for Ruggedized Motion Controller
  • MOOG D136-001-008 MSCI MSD Motion Controller
  • MOOG B95906-001 MSCI Motion Controller
  • MOOG B95865-001 CAN Termination Resistors
  • MOOG QEBUS-CAN Module
  • MOOG D136-003-001 Interfaces of Ruggedized Motion Controller
  • MOOG RDI0 16/16 Digital Module
  • MOOG D136-003-004 Interfaces of Ruggedized Motion Controller
  • MOOG D391-001-003 MSD MOTION CONTROLLER
  • MOOG D138-002-003 Industrial Control Module
  • MOOG MSC-R-10 16/8 Digital and PT100 Module
  • MOOG CB08987-001 Ruggedized Motion Controller
  • MOOG RDISP 22 Operator Panel DISPLAYS
  • MOOG D136-003-002 Interfaces of Ruggedized Motion Controller
  • MOOG CA65865-001 MSCl Motion Controller
  • MOOG B95863-001 CAN Connection Cables
  • MOOG QA10 16/4 Analog Module
  • MOOG D136-006-001 EtherCAT slave interface
  • MOOG D391-001-001 MSD MOTION CONTROLLER
  • MOOG D136-003-005 Interfaces of Ruggedized Motion Controller
  • MOOG D137-004-003 TFT Touch screen display
  • MOOG D138-002-003 Industrial Control Module
  • MOOG D138-003-010 Industrial Control Module
  • MOOG CB03223-001 Accessories for Ruggedized Motion Controller
  • MOOG B95864-001 CAN Termination Resistors
  • MOOG QD10 16/16 Digital Module
  • MOOG D391-001-002 MSD MOTION CONTROLLER
  • MOOG D138-001-010 Industrial Control Module
  • MOOG D138-001-005 Industrial Control Module
  • MOOG D138-001-002 Industrial Control Module
  • MOOG D138-001-001 Industrial Control Module
  • MOOG D137-002-001 Digital I/O modules
  • MOOG QEBUS-CAN Extension module
  • MOOG D137-001-010 Connection modules
  • MOOG D137-001-004 Digital I/O modules for E-Bus
  • MOOG D137-001-007 Digital extension module
  • MOOG G391-001-001 MSD Motion Controller
  • MOOG D138-002-001 Motion Controller
  • MOOG D137-004-004 TFT Touch screen display
  • MOOG D136-002-005 Ruggedized Motion Controller Interface
  • MOOG D137-001-006 Digital extension module
  • MOOG D136-002-004 Ruggedized Motion Controller Interface
  • MOOG D137-004-006 TFT Touch screen display
  • MOOG G391-001-002 MSD Motion Controller
  • MOOG D137-004-005 TFT Touch screen display
  • MOOG D137-001-005 Digital extension module
  • MOOG D136E001-001 Programmable Processor Module
  • MOOG D138-006-001 operation panel
  • MOOG G122-829-001 Programmable Processor Module
  • MOOG G761-3002B Industrial servo valves
  • MOOG T161-902A-00-B4-2-2A Servo Controller
  • MOOG M128-010-A001B DC Power Module
  • MOOG G391-001-003 MSD Motion Controller
  • MOOG D138-002-002 Motion Controller
  • MOOG D137-001-011 Digital extension module
  • MOOG D136-002-003 Ruggedized Motion Controller Interface
  • MOOG D136-002-002 Ruggedized Motion Controller Interface
  • MOOG D136-001-008a Ruggedized Motion Controller Interface
  • MOOG D136-001-007 Ruggedized Motion Controller Interface
  • MOOG D136-001-001 Ruggedized Motion Controller Interface
  • MOOG 914-GBE Gigabit Ethernet (GbE) Media Converter
  • MOOG 914-0300-00 ADVANCED MODULAR MULTIPLEXER SYSTEM
  • ABB UCD224A103 digital input/output module
  • ABB PDD205A0121 power distribution device
  • ABB PDD205A1121 power distribution device