Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

YOKOGAWA EJA110E Diff erential Pressure Transmitter

From:YOKOGAWA | author:Mr.Chen | Time :2026-01-31 | 423 view: | 🔊 Click to read aloud ❚❚ | Share:

The high performance diff erential pressure transmitter

EJA110E features single crystal silicon resonant

sensor and is suitable to measure liquid, gas, or

steam fl ow as well as liquid level, density and

pressure. EJA110E outputs a 4 to 20 mA DC signal

corresponding to the measured diff erential pressure.

Its accurate and stable sensor can also measure the

static pressure which can be shown on the integral

indicator or remotely monitored via BRAIN or HART

communications. Other key features include quick

response, remote set-up using communications and

self-diagnostics. FOUNDATION Fieldbus, PROFIBUS

PA and 1 to 5 V DC with HART (Low Power) protocol

types are also available. EJA-E series models in

their standard confi guration, with the exception of

the Fieldbus, PROFIBUS and Low Power types,

are certifi ed as complying with SIL 2 for safety

requirement.

 STANDARD SPECIFICATIONS

Refer to GS 01C31T02-01EN for Fieldbus

communication type and GS 01C31T04-01EN for

PROFIBUS PA communication type for the items

marked with “◊.”

□ PERFORMANCE SPECIFICATIONS

Zero-based calibrated span, linear output, wetted

parts material code S and silicone oil, unless

otherwise mentioned.

For Fieldbus and PROFIBUS PA communication

types, use calibrated range instead of span in the

following specifi cations.

Specifi cation Conformance

EJA-E series ensures specifi cation conformance to at

least ±3σ.

Reference Accuracy of Calibrated Span

(includes terminal-based linearity, hysteresis, and

repeatability)

□ FUNCTIONAL SPECIFICATIONS

Output “◊”

For 4 to 20 mA HART / BRAIN

(Output signal code D and J)

Two wire 4 to 20 mA DC output with digital

communications, linear or square root programmable.

BRAIN or HART FSK protocol are superimposed on

the 4 to 20 mA signal.

Output range: 3.6 mA to 21.6 mA

Output limits conforming to NAMUR NE43 can be

pre-set by option code C2 or C3.

For 1 to 5 V HART

(Output signal code Q)

Three or four wire low power 1 to 5 V DC output with

HART, linear or square root programmable.

HART protocol are superimposed on the 1 to 5 V DC

signal.

Output range: 0.9 V to 5.4 V DC

Failure Alarm

For 4 to 20 mA HART / BRAIN

(Output signal code D and J)

Analog output status at CPU failure and hardware

error;

Up-scale: 110%, 21.6 mA DC or more (standard)

Down-scale: −5%, 3.2 mA DC or less

For 1 to 5 V HART

(Output signal code Q)

Analog output status at CPU failure and hardware

error;

Up-scale: 110%, 5.4 V DC or more (standard)

Down-scale: −5%, 0.8 V DC or less

Damping Time Constant (1st order)

Amplifier damping time constant is adjustable from

0.00 to 100.00 s by software and added to response

time.

Note: For BRAIN protocol type, when amplifier software

damping is set to less than 0.5 s, communication

may occasionally be unavailble during the

operation, especially while output changes

dynamically. The default setting of damping

ensures stable communication.

Update Period “◊”

Differential pressure: 45 ms

Static pressure: 360 ms

Zero Adjustment Limits

Zero can be fully elevated or suppressed, within the

lower and upper range limits of the capsule.

External Zero Adjustment

External zero is continuously adjustable with

0.01% incremental resolution of span. Re-range

can be done locally using the digital indicator with

rangesetting switch.

Integral Indicator (LCD display, optional) “◊”

5-digit numerical display, 6-digit unit display and bar

graph.

The indicator is configurable to display one or up to

four of the following variables periodically.;

Measured differential pressure, differential pressure

in %, scaled differential pressure, measured static

pressure. See also “Factory Setting.”

Local Parameter Setting

(Output signal code D, J and Q)

Parameter configuration by the external zero

adjustment screw and push button (Integral indicator

code E) offers easy and quick setup for parameters

of Loop test, Tag number, Unit, LRV, URV, Damping,

Output mode (linear/square root), Display out 1. and

Re-range by applying actual pressure (LRV/URV)

and Device Information.

Burst Pressure Limits

69 MPa (10.000 psi) for wetted parts material S,

except for Measurement span F.

47 MPa (6.800 psi) for wetted parts material other

than S or Measurement span F.

Self Diagnostics

CPU failure, hardware failure, configuration error,

and over-range error for differential pressure, static

pressure and capsule temperature.

User-configurable process high/low alarm for

differential pressure and static pressure is also

available.

Signal Characterizer (Output signal code D, J and Q)

User-configurable 10-segment signal characterizer

for 4 to 20 mA output.

SIL Certification

EJA-E series transmitters except Fieldbus,

PROFIBUS PA and 1-5V DC with HART (Low Power)

communication types are certified in compliance with

the following standards;

IEC 61508: 2010;

Functional Safety of Electrical/electronic/

programmable electronic related systems; SIL 2

capability for single transmitter use, SIL 3 capability

for dual transmitter use.

Reliability Data different depending on hardware and

software revision.

For details, refer to Functional Safety Data Sheet.

(Document number: TI 01C25A05-01EN or TI

01C25A05-21EN for option code SLT )

The document can be downloaded from the website

of Yokogawa.

  • TMEIC TM21-TG Series 2-Pole Generator
  • TMEIC TM21-TG Series 4-Pole Generator for Turbine Drive
  • TMEIC Air-Cooled Type Synchronous Generators
  • TMEIC TMdrive-XL85 Medium Voltage AC Drives
  • TMEIC TMdrive-30 Medium Voltage AC Drives
  • TMEIC TMdrive-MVG2 Medium Voltage AC Drives
  • TMEIC TMdrive-70 Medium Voltage AC Drives
  • TMEIC TMdrive-50 Medium Voltage AC Drives
  • TMEIC TMdrive-MVe2 Medium Voltage AC Drives
  • TMEIC TMdrive-XL80 Medium Voltage AC Drives
  • TMEIC TMdrive-XL75 Medium Voltage AC Drives
  • TMEIC TMdrive-XL55 Medium Voltage AC Drives
  • TMEIC TMdrive-70e2 Medium Voltage AC Drives
  • TMEIC TMdrive-Guardian Medium Voltage AC Drives
  • TMEIC TMdrive®-10e2 DP DC Drives
  • TMEIC TMdrive-DCe2 DC Drives
  • TMEIC Dynamic VAR Compensation – Dyna-VAR™
  • TMEIC PV Inverters SOLAR WARE 2500
  • TMEIC PV Inverters SOLAR WARE 2700
  • TMEIC PV Inverters SOLAR WARE 3200
  • TMEIC Power Plant Controller
  • TMEIC High-voltage motors 21-L series
  • TMEIC MV Motor & Drive Solutions for Power Generation
  • TMEIC AC Motors Rolling Mills
  • TMEIC TMdrive®-70 Medium Voltage 3-Level IEGT System Drive
  • TMEIC TMdrive®-70e2 Medium Voltage 3-Level IEGT System Drive
  • TMEIC TMdrive-MVe2 Reactive Power Control
  • TMEIC TMdrive®-30 Medium Voltage 3-Level IGBT System Drive
  • TMEIC Unified Controller nv Series
  • DEIF MVR-F215 Product description
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF PPM 300 Protection & power management
  • DEIF RMC-142D Current relay
  • DEIF GPU-3 hydro Generator protection unit
  • DEIF MVR-200 series Medium Voltage Relay
  • DEIF RMC-131D Current relay
  • DEIF MDR-2 Multi-differential relay
  • DEIF AGC 150 ATS: Advanced Generator Transfer Switch for Seamless Power Management
  • DEIF DVC 350 Digital automatic voltage regulator (AVR)
  • DEIF Digital Voltage Controller DVC 550
  • DEIF TAS-331DG AC transducer for active or reactive power
  • DEIF RMV-112D Undervoltage and overvoltage relay
  • DEIF DPS-1 DC Power Supply
  • DEIF DM 400 hydro Integrated systems
  • DEIF DBC-1 Battery charger
  • DEIF CSQ-3 Multi-function synchroscope
  • DEIF CODESYS Features Software - AWC 500 development package
  • DEIF AMC 300 Advanced Programmable Controller
  • DEIF AGI 400 Advanced graphical interface
  • DEIF BRW-2 & BW Analogue illuminated bridge wing indicators
  • DEIF AWC 500 - G59/3 Integrated G59/3 protection turbine controller unit
  • DEIF AWC 500 Advanced Controller
  • DEIF ASK & ASR Measuring transformer
  • DEIF ASC-4 Battery Automatic Sustainable Controller
  • DEIF ASC plant management Automatic sustainable controller
  • DEIF AOP Additional operator panel
  • DEIF AMC 600 Programmable automation controller with EtherCAT based I/O
  • DEIF AL8-2 Alarm panel
  • DEIF AGC 150 Hybrid Advanced Genset Controller
  • DEIF AGC 150 PMS Lite Simple power management controller
  • DEIF AGC 150 Generator Advanced Genset Controller
  • DEIF AGC 150 Remote Display Remote access and control unit
  • DEIF MVR-250 series Medium Voltage Relay
  • DEIF MVR-210 series Medium Voltage Relay
  • DEIF The SGC series
  • DEIF iE 350 Marine Highly flexible and cybersecure intelligent energy controller
  • DEIF iE 250 Marine Versatile and cybersecure intelligent energy controller for maritime applications
  • DEIF iE 150 Marine Simple and effective power management
  • DEIF iE 650 PLC Extreme robust Programmable Automation controller with EtherCAT based I/O
  • DEIF iE 350 PLC Robust right out of the box
  • DEIF iE 250 PLC Versatile and modular intelligent energy PLC controller
  • DEIF XL / BW / BRW-2 Illuminated indicators
  • DEIF SGC 120/121 Single Genset Controllers
  • DEIF Load Sharing Unit LSU-112DG
  • DEIF Automatic Genset Controller AGC-4
  • DEIF DU-2/MKIII Paralleling And Protection Unit 24VDC
  • DEIF AGC-4 Mk II Generator Set Automatic Controller
  • DEIF GPU-3 graphics card Generator protection unit
  • DEIF SGC 410 Single Genset Controller
  • DEIF SGC 110 Single Genset Controller
  • DEIF MTR-3 Multi-sensor
  • HIMA HIMax® HART Communication Module X-HART 32 01
  • HIMA 22121 Output modules
  • HIMA 22120 Output modules
  • HIMA 32110 Relay Amplifier – SIL 4 Certified Safety Module
  • HIMA 32103 Relay Amplifier – SIL 4 Certified Safety Module
  • HIMA 32102 Relay Amplifier – SIL 4 Certified Safety Module
  • HIMA 32102 Relay Amplifier – SIL 4 Certified Safety Module
  • 32100 | HIMA 2 Channel Relay Amplifier
  • HIMA 42500 Selection element,2003 voting Logic function modules
  • HIMA 42400 Blocking element, direct and inverted output Logic function modules
  • HIMA 42300 OR element with 2 inputs Logic function modules
  • HIMA 42200 Element combination AND/OR/blocking element Logic function modules
  • HIMA 42100 AND element with S inputs, 1 with OR Logic function modules
  • HIMA 52100 Time Delay Module
  • HIMA 62100 984162100 2-Fold Analog Limit Monitor
  • HIMA 80110 Reset module
  • HIMA HIMatrix Safety-Related Controller F3 AIO 8/4 01
  • HIMA HIMax®Relay Module X-D0 12 51
  • HIMA HIMax®Relay Output Module X-DO 12 01
  • HIMA HIMax®Digital Output Module X-DO 32 51
  • HIMA HIMax®Counter Module X-C1 24 51
  • HIMA HIMax®Digital Input Module X-DI 16 01
  • HIMA X-DI 32 52 Digital Input Module
  • HIMA HIMax® Analog input module X-AI 32 01
  • Beckhoff EL1904 | EtherCAT Terminal, 4-channel digital input, 24 V DC, TwinSAFE
  • Beckhoff EL1899 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 10 µs, ground switching
  • Beckhoff ED1897 | EtherCAT Terminal, 32-channel digital input
  • Beckhoff EL1489 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff ED1889 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1889 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1872-0010 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1872 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1862-0010 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff EL1862 | EtherCAT Terminal, 16-channel digital input
  • Beckhoff ED1859 | EtherCAT Terminal, 8-channel digital input
  • Beckhoff EL1859 | EtherCAT Terminal, 8-channel digital input
  • Beckhoff EL1852 | EtherCAT Terminal, 8-channel digital input
  • Beckhoff ED1819 | EtherCAT Terminal, 16-channel digital input, 24 V DC, 10 µs, push-in
  • Kollmorgen S200 Series S20350-VTS SERVO DRIVE
  • Kollmorgen ServoStar CD CR06250 PRD-0030000z-45 , 1.4/2.2KVA Servo Drive Rev M
  • KOLLMORGEN AKD-P02407-NBEC-0000 Servo Drive
  • Kollmorgen ME2-405-B-A2 Goldline Servomotor-Encoder Commutated
  • KOLLMORGEN AKD-P00606-NBCC-I000 SERVO DRIVE
  • Kollmorgen MV65WKS-CE310/22PB Servo Drive Control Module 220v 22a
  • KOLLMORGEN SERVOSTAR 303 S3036 1-SE SERVO DRIVE
  • Kollmorgen S20360-VTS-021 Servo Drive