and over-range error for differential pressure, static
pressure and capsule temperature.
User-configurable process high/low alarm for
differential pressure and static pressure is also
available.
Signal Characterizer (Output signal code D, J and Q)
User-configurable 10-segment signal characterizer
for 4 to 20 mA output.
SIL Certification
EJA-E series transmitters except Fieldbus,
PROFIBUS PA and 1-5V DC with HART (Low Power)
communication types are certified in compliance with
the following standards;
IEC 61508: 2010;
Functional Safety of Electrical/electronic/
programmable electronic related systems; SIL 2
capability for single transmitter use, SIL 3 capability
for dual transmitter use.
Reliability Data different depending on hardware and
software revision.
For details, refer to Functional Safety Data Sheet.
(Document number: TI 01C25A05-01EN or TI
01C25A05-21EN for option code SLT )
The document can be downloaded from the website
of Yokogawa.