INTRODUCTION
Basler Electric’s BE3-GPR Generator Protective Relay provides total
generator protection in a single package. Its microprocessor-based
design provides high accuracy, reliability, and repeatability. The BE3
GPR provides protection for paralleled generating systems or stand
-alone, isolated generating systems.
BE3-GPR setup and configuration can be performed using the provided
Windows®-based setup software or the front panel interface.
Because of the BE3-GPR’s low sensing input burdens, no dedicated PTs
or CTs are required. all current sensing inputs are isolated.

A set of Form C (SPDT) output contacts are provided for each protection
function and the internal diagnostics function.
The enclosure for the BE3-GPR is dust- and moisture-resistant.
Metal case construction enhances the BE3-GPR’s resistance to
electromagnetic interference.
FEATURES
BE3-GPR features include protection functions, contact inputs, internal
diagnostics, front panel indicators, and communication capabilities.
Protection Functions
BE3-GPR protection functions include:
• Overcurrent (51): style selectable as either three-phase or neutral
ground fault
• Phase balance (47)
• Loss of excitation (40)
• Sync-check (25)
• Overfrequency (81O)
• Underfrequency (two 81U elements)
• Reverse power (32R)
• Dead bus
Contact Inputs
Four continuously monitored contact inputs accept switch inputs or
jumpers and perform the following functions.
Trip Reset. Clears all tripped functions when auto reset is disabled.
Program Enable. Enables setting changes to be made at the front panel.
Failsafe Enable. Changes output contact operation to failsafe mode
(output relays are energized during
normal, non-tripped conditions).
Output Enable. Disables the output contacts. This feature prevents
nuisance tripping during generator buildup.
Internal Diagnostics
Internal diagnostics are provided by a watchdog timer. The watchdog
timer monitors for proper firmware execution and microprocessor
operation. If an internal operating error occurs, the Watchdog Timer
(WDT Fail) output contacts change state to annunciate the problem.
Front Panel Indicators
Front panel indicators consist of a liquid crystal display (LCD) and a
Sync LED indicator. The front panel LCD serves as the main user
interface and displays all information necessary for programming
and interpreting BE3-GPR actions.
The Sync LED lights to indicate that the generator is synchronized with
the bus. The Sync LED also lights when a dead bus condition exists.
Communication
An RS-232 serial port enables communication between the BE3-GPR
and a PC operating the BE3-GPR communication software.
BE3-GPR communication enables relay configuration and real-time metering
of power system parameters.