DESCRIPTION

BE1-87T Transformer Differential Relays provide primary protection for power transformers and are

available in either Single-Phase or Three-Phase configurations. The solid-state BE1-87T compares the

currents entering and leaving the protected transformer. If a fault is detected, the relay initiates a trip

signal to isolate the power transformer. This limits damage to the transformer and minimizes the impact

on the power system.

BE1-87T relays use three types of restraint:

• Percentage of through-current

• Second harmonic

• Fifth harmonic

Selectivity in differential relaying is based on the ability to distinguish between internal and external faults.

This is achieved by comparing the currents into and out of a power transformer. Comparing these

currents often requires more than two inputs. For example:

• Power transformers may have a significant portion (greater than 10 %) of the current flowing in a

third or tertiary winding.

• Power transformers can have multiple breakers for a given winding (e.g., ring bus or breaker

and-a-half bus).

BE1-87T relays are available with up to five restraint inputs for the single-phase unit and up to three

restraint inputs per phase for the three-phase unit.

APPLICATION

In general, power transformers have different values of current flowing through their primary, secondary,

and tertiary windings. These currents have specific phase relationships depending upon the connections

of the individual windings (e.g., wye/delta). As inputs to a differential relay, these currents must be

compensated or scaled so that the relay can compare the inputs and determine when an unbalance

exists. Under ideal operating conditions, the scaled vector sum of these currents is zero.

Because it is practically impossible to match the magnitudes of these detected currents from the various

power windings using standard CT ratios, the currents are matched within the relay by scaling each of the

applied currents by an appropriate factor called a Tap Setting. This is set by means of the front panel

INPUT dials. By selecting suitable tap ratios, the applied currents are scaled within the relay to achieve

the desired balance for normal operating conditions. BE1-87T relays offer a range of available tap settings

for inputs between 0.4 A to 1.78 A (Sensing Input Range Options 2 and 4 for a 1 A CT) or 2.0 to 8.9 A

(Sensing Input Range Options 1 and 3 for a 5 A CT). These settings are independently adjustable in

increments of 0.02 A for Sensing Input Range Options 2 and 4. or 0.1 A for Sensing Input Range Options

1 and 3. These small increments allow more precise scaling of the applied currents and usually eliminate

the need for installing auxiliary ratio-matching CTs.

Single-Phase

BE1-87T Single-Phase relays require phase angle compensation to be accomplished externally by proper

connection of the system CT secondaries. A wye/delta transformer requires that the CT secondaries be

connected in delta for the wye winding and in wye for the delta winding. This type of connection also

eliminates the zero-sequence component of current which could cause a false trip (operation) during

external ground fault conditions on the wye system.

Three-Phase

BE1-87T Three-Phase relays can provide zero-sequence filtering and compensation for phase shifts

introduced by the connections of the power transformer. This 30° Phase Shift compensation (either ±30°

or no compensation) is field selectable. Additionally, this feature allows sharing the transformer differential

relay CTs with other relays or instrumentation.

BE1-87T relays use the highest input current (in per unit values) to operate on maximum restraint. The

relay does not have a conventional operate winding in the internal magnetics. Operating current is

developed within the electronics of the relay.

Percentage Restraint

A primary concern in differential relay applications is security against high current levels caused by faults

outside the protected zone. Inevitable differences in the saturation characteristics between current

transformers require a compensating decrease in relay sensitivity. It is also necessary to be able to adjust

  • Eaton 1023843 Power Board B20098140711 A5
  • Eaton PDG23F0125VFFJ Power Defense molded case circuit breaker
  • Eaton 9130 1KVA Marine Filter Pn 1029424 Rev 002 220/230/240VAC 50/60Hz 1603
  • Eaton/Dynamatic 15-871-6 AF5000+ Power Supply Board P-CTR 158716
  • EATON D80JE22A PNEUMATIC TIMER SER.A2
  • Eaton - Cutler Hammer PXM1000MB15-1 PXM 1000 METER; DISPLAY; 5A; 100-415AC/1
  • Eaton Cutler Hammer IQDP-4000 IQ DP-4000 66D2040G03
  • Eaton F801 8 Segment Redundant Fieldbus Power Supply
  • Eaton PXM-4KUPG Power Xpert Meter 4000 to 6000 license upgrade key
  • Eaton PX-PMBC Panel mounting bracket assembly required for reduced graphic display rear clearance
  • Eaton PX-PMBB Panel mounting bracket assembly for retrofitting a graphic display to an IQ analyzer cutout
  • Eaton PX-PMBA Panel mounting bracket assembly for back-to-back meter to graphic display mounting
  • Eaton PXMCE-B Communications expansion card: Ethernet 100FX, 10/100T, RS-485, RS-232
  • Eaton PXMIO-B Digital I/O card: 8 digital input, 2 solid-state output, 3 relay output
  • Eaton PXD-MMG Graphic display module
  • Eaton PXM4051A1AB Power Xpert meter 4000
  • Eaton / Cutler Hammer PXM4000 PXM4051A1BB
  • Basler Electric BE1-59-A4E-E1C-A0N0F / BE159A4EE1CA0N0F Over Voltage Relay
  • Basler Electric SR4A-2B05A3E Static Voltage Regulator SR4A2B05A3E
  • Basler Electric 9-0723-00-130 / 9072300130
  • Basler Electric BE1-79MA10A6JC0L0F / BE179MA10A6JC0L0F
  • Basler Electric CBS-377 CURRENT BOOST SYSTEM PART NO 91096001
  • Basler Electric SR4A1B05A3A Static Voltage Regulator 480v-ac 62.5v-dc 10va
  • Basler Electric BE159N A7ED1JC0S0F Solid State BE159N-0 Protective Relay
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K2EW6MB1N0F
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50 Style G4EA1RG0N0F
  • Basler Electric BE1A-25-M1G-A6T-N4V1F Sync-Check Relay
  • Basler Electric SR8A2B10B1A STATIC VOLTAGE REGULATOR
  • BASLER TIME OVERCURRENT RELAY BE1-51A SOLID STATE 1 PH
  • Basler Electric SSR 125-12 STATIC VOLTAGE REGULATOR 9185900102
  • Westinghouse 2374A07G03 Power Supply Basler Electric 90-73900-102
  • 9400200117 - Basler Electric - CONTROL POWER UNIT - 12/24VDC 20WATT
  • Basler Electric Static Voltage Regulator SR32A2B05B3E
  • Basler Electric SR8A2B06B3A Static Voltage Regulator / SR8A2BO6B3A
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY B1EZIPB1N0F
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50-51B-219
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EW6MB0N0F
  • Basler Electric SBO226 Excitation Support System
  • Basler Electric SBO225 Excitation Support System
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EZ1PA0N0F
  • Basler Electric MOC3502 | 90-72300-116 MOTOR POTENTIOMETER
  • Woodward 1751-6058 4 Channel MPU Transformer Module
  • Basler Electric 2D80367G23 DXCB De-Excitation Module 1200V 5000A Excite
  • Basler Electric SSR 63-12-9185900101 Static Voltage Regulator
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K1EW5MB0N0F
  • Basler Electric MODEL SSR 125-12NF STATIC VOLTAGE REGULATOR 9 1859 00 106
  • Basler Electric Breaker Protection Relay BE1-BPR 9272000315
  • Basler Electric SBO224 Excitation Support System
  • Basler Electric SSR 63-12 Static Voltage Regulator 9 1859 00 101 46534AB
  • Basler Electric AEM-2020 ANALOG EXPANSION MODULE
  • Basler Electric BE 25231-001 Transformer BE25231001
  • Basler Electric PSS-100-Y5 Power Sys Stabilizer dampening oscillations 0.1-5.0Hz
  • Basler Electric BE1-87G-S1A-A1C-A0N0 Variable Percentage Differential Relay
  • Basler Electric SR8A-2B06B3E Static Voltage Regulator SR8A2B06B3E
  • Basler Electric SOLID STATE FREQUENCY CONTROLLER SCP-210 /SCP210 P/No:9095400100
  • Basler Electric BE1-59-A3E-A1J-N1N3F / BE159A3EA1JN1N3F Over Voltage Relay
  • Basler Electric SBO223 Excitation Support System
  • Basler Electric P/N 9 2011 11 100 BRACKET MOUNTED TERMINAL UNIT
  • Basler Electric P/N 9 2011 11 100 BRACKET MOUNTED TERMINAL UNIT
  • Basler Electric voltage regulator P/n: 9 1606 00 101
  • Basler Electric Current Boost System | Model No. CBS-377 P/N 9109600102
  • Basler Electric 8650C72 Exciter Control Module Pcb Board Rev 5
  • Basler Electric 9252000258 Be1-50/51b Overcurrent Relay
  • Basler Electric SR8A-2B01B3A Static Voltage Regulator SR8A2B01B3A
  • Basler Electric SR4A-2B01B3E Static Voltage Regulator SR4A2B01B3E
  • Basler Electric 9017709102 PC Board
  • Basler Electric 9066800102 Excitation Support Systems 9066800-102
  • Beckhoff ELX3152-0090 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELX3158 | EtherCAT Terminal, 8-channel analog input, current, 4…20 mA
  • Beckhoff ELX3152 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3704-1001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0020 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3702-0101 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3702-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3604-0002 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3604-0000 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0032 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0030 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0002 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0000 | EtherCAT Terminal, 2-channel analog input
  • Beckhoff ELM3544-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3542-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • ENOTEC GAS ANALYZER SYSTEM OXITEC 5000 SME-53310000
  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch