Correctly configuring protection with confidence has never been easier
than with the BE1-11. The BE1-11 Protection System is designed with
many features to address issues with reliability arising from the
complexity of programming. With BESTspace™ files, multiple BESTlogic™Plus
preprogrammed logic schemes, and associated application notes, you can
be confident that you have the protection you need.

A single firmware that can apply across a variety of applications, including
Feeder, Intertie, Motor, Generator, Transformer and DC Power protection
applications. See the product bulletin for functions available in each style.
Product Features & Benefits
• Entering protection settings with confidence is easy with BESTCOMSPlus®
software that provides intuitive settings with graphs, built-in error checking,
and summary screens.
• Complex protection is easy to configure and understand with preprogrammed
schemes, drag-and-drop logic, user labels, and notes provided by BESTlogic™Plus.
• The Offline Simulator in BESTlogic™Plus helps identify and troubleshoot the
logic without the expensive need for physical hardware.
• Adaptable coordination for difficult applications is made possible by 24
industry-standard timing curves and near infinite user-defined curves.
• Meet your modern communications needs with 10/100Mbit copper or 100Mbit
fiber-optic Ethernet with IEC 61850. DNP, or Modbus®.
• Connection is easy, even when using multiple large wires, with large screw
terminals for all terminations.
• Get the information you need for system analysis with distance-to-fault,
oscillography, demand metering, power quality, breaker monitoring, and other
data provided by the BE1-11.
• Easily navigate settings and metering with the intuitive Human Machine
Interface (HMI) menu and large LCD display.
• Customize displayed information to meet different application needs with
user-definable indicators and labels.
• Direct control of internal logic using Select-and-Operate buttons available
on the front panel.
• Fully configurable analog outputs can be used to drive analog meters.
Easily assigned trip points can be scaled by the user to reflect measured
parameters.
• Up to 14 combined alarm and trip temperature monitoring points are possible
using an optional RTD module.
• Reduce installation costs and improve reliability by mounting an optional RTD
module near the point of measurement to minimize cable lengths.