Basic functions
Basic functions are reinforced so that R3132/3162 can be used in various fields. For example, the internal automatic calibration function guarantees the total level accuracy of ±1.5dB, level correction factor can be stored in the internal memory, DDS is employed to improve frequency reading accuracy, and frequency span error is lowered to less than 1%.
The R3132/3162 offer wider dynamic range and lower 2nd and 3rd distortion by improving 1dB compression point.
As a result of increasing the sweep repetition cycles by improving the synthesized local oscillator, 20 traces/second (typ.) data rewriting becomes possible, enabling far more real-time waveform measurement.
high speed GPIB increase, the throughput of automatic measurement.
For many applications
For EMI precompliance measurement, 6-dB bandwidth filters for 9kHz, 120kHz and 1MHz as well as QP detector are equipped as standard. Optional 200Hz narrow RBW filter can be added.
For high-speed time domain measurement function which is indispensable for mobile communications, optional 50µs sweep is effective.
By using the double-screen display function, you can specify the rising/falling edge of TDMA waveform and display the magnified image.
The R3132/3162 series spectrum analyzer has ACP and OBW operation function indispensable for evaluating the transmission characteristic of radio system.
With various other functions such as AUTO TUNE, 1Hz resolution frequency counter, dBc/Hz, %AM, and PASS/FAIL test by limit value, the R3132/3162 series can easily perform several types of measurements.
Even for signals which are lower in level than the average noise level, the preamplifier ensures level calibrated, high-accuracy measurement.
For measuring the attenuation characteristic of filters or the frequency characteristic of cables, etc., built-in tracking generator is available as option. Because the output level can be set in a wide range, it is possible to measure amplifier gain, frequency response, etc.
Easy-operation interface
The high-resolution, 6.5-inch TFT color LCD realizes easy-to-see display of data. VGA output is provided for external display.
Measured waveform data and setting condition can be saved in or recalled from the internal memory. Using the floppy disc drive which is equipped as standard, you can manage more number of measurement data. Text data or Bitmap data on floppy disc are also useful for making documents on a personal computer.
As the hard-copy function is provided to ESC/P. ESC/P-R and PCL, measured data can be printed out on general-purpose printers.
GPIB and RS232 are equipped as standard.
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com