A-B Remote I/O Communication Interface Module How to Identify Module Functions

From:A-B | author:Mr.Chen | Time :2024-07-22 | 948 view: | 🔊 Click to read aloud ❚❚ | Share:

ControlLogix AutoMax DCSNet and AutoMax

Remote I/O Communication Interface Modules

Identifying Module Functions

Refer to the following diagram to identify the hardware components of the 56AMXN/B module.

The module has

- Labels that identify the AutoMax DCSNet scanner and remote I/O

- A 4-character scrolling display (XXXX)

- 3 LEDs labelled NET, CLX, and OK to indicate network status, connection to the ControlLogix processor, and its own internal status

- A 9-pin D-type connector for connection to a DCS or remote I/O network

- Switches on the top of the module to set the mode of operation, number of drop-downs, and depth of drop-downs

Switches to set network type and node address

The switches on the top of the module must be used to set the network type, dropdown number, and dropdown depth before installing the module.

The two switches on the left set the dropdown depth and the two switches on the right set the dropdown number.

The following table shows how to set the switches for each mode of operation.

For example, to configure the 56AMXN/B as a DCS slave with a dropdown number of 17 and a dropdown depth of 5. set the switches from left to right to 0. 5. 1. and 7.

Any other setting is invalid and causes the module to enter the Fingerwheel Test mode. In Fingerwheel Test mode, the display shows the current switch settings.

It will not exit the thumbwheel test mode until power is removed.

In the Thumb Wheel Test Mode, the 56AMXN/B initially displays ‘Thumb Test Mode’ on the 4-character display, the

The display switch is set for 5 seconds, then the display resumes showing ‘Thumb Test Mode’.

For DCS slave operation, if the air drop number and air drop depth are individually valid but combined produce an invalid melt

If the drop number and drop depth are valid individually, but the combination produces an invalid drop number (e.g., drop number 55.), the module will display the drop number in the 4-character display,

then the module will display an error message on the 4-character display, but will not enter the thumbwheel test mode.

but will not enter the thumbwheel test mode.

Determining Module Slot Location

The following figure shows the slot numbering for a 4-slot chassis. Slot 0 is the first slot

Always the leftmost slot in the rack (first slot to the right of the power supply).

You can use any size ControlLogix chassis and install modules in any slot.

You can also install multiple 56AMXN/B modules in the same chassis. The number of modules the power supply can hold (i.e., the power supply's rating).

Installing or Removing Modules When the Power Supply is Connected

56AMXN hardware versions prior to O-57677-1 do not support the removal and insertion of modules while powered on.

Hardware versions can be identified by looking for a sticker with part number

O-57677-1 or later stickers (near the serial number - you do not need to disassemble the 56AMXN module.

(You do not need to disassemble the 56AMXN to find the sticker). Modules without stickers are hardware version O-57677 and do not support removal and insertion while powered on.

For modules with hardware version O-57677-1 and above, you can install or remove the module with the chassis powered on if the following precautions are followed.

Wiring the AutoMax Network Connector

Connect the module to the coaxial network cable using the 612574-36R step-down cable and passive tap changer M/N 57C380 provided by Rockwell Automation Systems Business Unit.

The cable is down-turned and has a ferrite to reduce EMI. it must be used for CE applications. You can also use the drop cable 612403-036R, but it points upward.

The drop cable is a 3 ft long multi-core cable with a 9-pin D-shell connector on each end. One end connects to the connector on the module and the other end connects to the passive splitter.

The passive splitter has two BNC connectors for connecting the coaxial cable to the termination load.

The network coaxial cable must be connected to the splitter at the physical end of the network using a 75-ohm termination load. There should be and only two terminators on the network.

For DCS, the network cable can be either RG-59/U or RG-11/U. For remote I/O, the cable must be RG-59/U.

Powering Up the Rack

Turn on the rack power.

  • Beckhoff ELM3602-0030 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0002 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0000 | EtherCAT Terminal, 2-channel analog input
  • Beckhoff ELM3544-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3542-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • ENOTEC GAS ANALYZER SYSTEM OXITEC 5000 SME-53310000
  • Autronica Repeater panel BU-BV-420G2
  • Autronica Maritime gas alarm control panel kit BS-420MG
  • Autronica SD CARD REPLACEMENT IN BC-440, BC-420, BS-420, BS-430 AND BU-BV-420
  • Autronica Operator panel BS-430G2
  • Autronica Controller rack unit BC-440G2
  • Autronica Controller BC-420G2
  • Autronica Fire and gas alarm control panel BS-420G
  • Autronica AutroSafe 4 integrated fire and gas (IFG) panels
  • Autronica POWER CABINET BP-405
  • Autronica Fire brigade loop panel BU-110
  • Autronica Information loop panel BV-110
  • Autronica Repeater Panel BU-BV-420
  • Autronica Operator Panel BS-430
  • Autronica Controller rack unit BC-440
  • Autronica Controller BC-420
  • Autronica MARITIME STD. SOLUTIONS BS-420M (CABINETS AND MOUNTING PLATES)
  • Autronica FIRE ALARM CONTROL PANEL BS-420
  • Autronica Mimic cabinet BUR-200, for maritime installations
  • Autronica MIMIC DRIVER BUR-200
  • Autronica INFORMATION PANEL BV-210
  • Autronica FIRE BRIGADE PANEL BU-210
  • Autronica BS-211 REPEATER PANEL
  • Autronica BS-200M FIRE ALARM CONTROL PANEL
  • Autronica FIRE ALARM CONTROL PANEL - BS-200
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO (MATURE)
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature, thermocouple
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • HIMA H6200A DIN rail Safety Analog Isolation Module Transmitter Circuit
  • Eaton CORPORATION IQMESIIN1 METER
  • Eaton DT223UGK Heavy duty double-throw non-fused safety switch
  • Eaton 5884-1400 6-Digit Dual Preset Control W/ Batch Control
  • Eaton 1023843 Power Circuit Board 94V
  • EATON ES4P-221-DRXD1 24VDC NSMP
  • Eaton DH222NWK heavy duty fusible safety switch
  • Eaton Touch Panel 10.1 inch XV-303-10-C00-A00-1C
  • Eaton RDF200J-3 Bussmann series RDF fused rotary disconnect switch
  • EATON CORPORATION A200M2CACD A200 NEMA Motor Control
  • Eaton SPD160208Y3J Surge Protection Device
  • EATON CORPORATION SPD160208Y3K SURGE SUPPRESSOR
  • EATON DILM400/22 (RA250) 200KW Coil Voltage/Coil 110-250V 40-60Hz/DC
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • EATON CORPORATION D820MPM HMI
  • EATON PXG900 Power Xpert Insight Gateway 900
  • Eaton Durant 5882-7 Digital Counter loc2D3
  • EATON AXCELIS 1220-0012-0002 DISK VACUUM DI CONTROLLER
  • Eaton 1383B-6501 80 Series Photoelectric Sensor Head
  • Eaton FDC2100L Series C molded case switch
  • Eaton XV-430-10TVB-1-10 139902 Touch Panel
  • Eaton FD3200L circuit breaker
  • Eaton Touch Screen Control Panel X-152-D6-10TVRC-10
  • EATON VICKERS EEA-PAM-523-A-32 02-326001 POWER AMPLIFIER
  • Saacke Seavis HMI 03 EATON XV-102-B6-35TQR-1AL-PLC HMI Touch Panel
  • EATON MTL E05016 DIGITAL INPUT EUROCARD E05516-2134
  • Eaton HFD3150 3P 150A 600VAC Circuit Breaker
  • Eaton HMIVU06CUNB1 HMi Operator Interface, RS-232, 5.6"
  • Cutler-Hammer/ Eaton Panelmate PowerPro 5785 with cables LCD monitor
  • Eaton D100CA40 40 I/O Micro PLC 115VAC Input Triac Output
  • EATON CUTLER HAMMER 66D2032GX1 MP-3000 PROTECTION RELAY
  • EATON R9L3200FJ Rotary Disconnect Switch
  • EATON CORPORATION E51CLT16PCU Switch
  • Aerotech Modular System Control Console
  • Aerotech TV Series Transformers
  • Aerotech TM5 Transformer Module (500 watts)
  • Aerotech TM3 Transformer Module
  • Aerotech UFM Noise Filter Module
  • Aerotech MFM10-2 Motor filter module
  • Aerotech MFM10-1 Motor filter module
  • Aerotech MPG Handwheel Pendant
  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3246-0000 | EtherCAT Terminal, 6-channel analog input, temperature
  • Beckhoff ELM3244-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3148-0000 | EtherCAT Terminal, 8-channel analog input, multi-function
  • Beckhoff ELM3146-0000 | EtherCAT Terminal, 6-channel analog input, multi-function
  • Beckhoff ELM3144-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckwith Electric M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-3919A Graphic Display Unit/ Human Machine Interface
  • Beckwith Electric M-4172 Digital Motor Bus Transfer System
  • Beckwith Electric M-3904B Remote Monitoring Module
  • Beckwith Electric M-3410A Intertie/Generator Protection Relay
  • Beckwith Electric B-1612 Adapter
  • Beckwith Electric B-1652 Adapter
  • Beckwith Electric B-1685 Adapter
  • Beckwith Electric M-2035 Analog to Digital Interface Module
  • Beckwith Electric B-2291 Digital Input Guard
  • Beckwith Electric M-2406 Recloser Control Adapter Chassis
  • Beckwith Electric M-3908 Universal Contact Input Adapter
  • Beckwith Electric M-3801D IPS Plot Software
  • Beckwith Electric M-7651A D-PAC
  • Beckwith Electric M-2979 Recloser Control Cabinet
  • Beckwith Electric M-0359 SYNCROCLOSER MOD512
  • Beckwith Electric M-2001C-6ELFA Tap Changer Controller Voltage Regulator Control
  • Beckwith Electric M-0124 TERMINAL BOARD ADAPTER PLATE 13 POS
  • Beckwith Pride M-0296C 3ph Programmable Relay
  • Beckwith Electric M-0388 Syncrocloser Check Relay
  • M-0170A AC Current Relay Beckwith Electric
  • Beckwith Electric Intertie Protection M-3520 Instruction Manual
  • M-3311 M-3311 7113 BECKWITH ELECTRIC TRANSFORMER PROTECTION RELAY
  • Pride M-0296b 3 phase Programmable Relay Beckwith Electric Co
  • Beckwith Electric M3310 Integrated Transformer Protection Panel
  • Beckwith M-0145 First Customer Protector
  • Beckwith Electric M-0296C 3 phase Programmabel Relay
  • Beckwith Electric M-0389 VOLTAGE VERIFIER
  • M-3425 M-3425-A1DE BECKWITH ELECTRIC GENERATOR PROTECTION RELAY SL
  • Beckwith Electric M-0420 Multifunction Relay Protection Module 48VDC
  • M-3430 M-3430M0D515 BECKWITH ELECTRIC GENERATOR PROTECTION RELAY