8507-BI-DP BIM and 8701-CA-BI Carrier
PROFIBUS DP Bus Interface Module and Carrier
The 8507-BI-DP Bus Interface Module (BIM) provides the communications
link between the PAC8000 series I/O modules and a PROFIBUS-DP host.
High-speed acquisition of data from the modules and LAN operation speeds
of up to 12 Mbaud allow the host to respond rapidly to changes in process
conditions.
The BIM gathers data from the I/O modules and makes it available to the
host upon request. It is a slave tothe PROFIBUS master. As well as cyclic
data exchange, which is required for reading input and writing output data,
the BIM supports PROFIBUS Extended Diagnostics for status information.

The BIM(s) must be used with an 8701-CA-BI Redundant BIM Carrier, described
on page 4.
Redundant BIMs can be used for critical applications. Each BIM in the redundant
pair operates in parallel, continually checking status to enable the backup BIM to
monitor the health of the primary BIM.
8507-BI-DP Bus Interface Module
For details on the installation and operation of the BIM, refer to the PAC8000 I/O
- PROFIBUS DP BIM Instruction Manual, INM8507.
Features
support for up to 24 I/O modules
redundant operation
extended diagnostics for module and channel status
PROFIBUS network speeds of up to 12 Mbaud
non-volatile memory for configuration
configurable via PROFIBUS host
HART Pass-through support to monitor/configure HART devices
Configuration/Reset of IP address
Parameterization
The 8507-BI-DP supports parameterization from the PROFIBUS master.
The configuration is created in a PROFIBUS configurator using details provided in
a GSD file. This method is fast and enables a configuration to be built based upon
“logical” modules which represent the physical modules. Modules are added one
at a time to the configuration.
The configuration is passed from the PROFIBUS master to the BIM at the start of
communication. If the system is stopped and re-started, or if the node goes through
a cold start cycle, the configuration file is retransmitted to the BIM.
Standard and Extended Diagnostics
The PROFIBUS BIM supports Standard and Extended Diagnostics. While the Standard
Diagnostics provide standard PROFIBUS status information, the Extended Diagnostics
provide detailed information relating to the status of the BIM, the health of the modules
and the status of I/O channels. Depending on the I/O module type, events such as high
and low alarm, open circuit and line fault are detected.
Extended Diagnostic messages are generated on detection of any anomalies in I/O
modules. Use of the diagnostic capability requires suitable support in the host application.
For hosts unable to use diagnostic data in the control algorithm, it is possible to map the
diagnostic data into the input dataframe.

8701-CA-BI Redundant BIM Carrier
For details on the installation and operation of the BIM Carrier, refer to the PAC8000 I/O
- PROFIBUS DP BIM Instruction Manual, INM8507.
Features
accommodates two Bus Interface Modules
supports PROFIBUS-DP
provides dual PROFIBUS network connections
can be used with DIN rail or panel mounting