Mechanical description
• Locking door with polycarbonate window.
• Latching front panel assembly swings forward for convenient
internal access.
• Smooth box surfaces are provided for locally cutting conduit
entrance holes exactly where required.
• Modules are power-limited except as noted, such as relay
modules.

• The battery compartment at the bottom, has space for two
batteries, up to 18 Ah. You can mount batteries within the cabinet
without interfering with module space. Charger capacity is up to
33 Ah. For information about batteries greater than 18 Ah and
external battery cabinets, see Module and accessories selection
information.
• Cabinet assembly design has been seismic tested and is certified
to IBC and CBC standards also to ASCE 7 categories A through
F, requires battery brackets. For more information, refer to data
sheet S2081-0019.
• Seismically compliant under the State of California Statewide
Office of Housing and Development (OSHPD) Special Seismic
Certification (SSC) program guidelines. Refer to Simplex Seismic
Application Guide 579-1213 and Battery Brackets for Seismic Activity
Applications S2081-0019 for details.
IDNet 2 addressable device control
The 4007ES Hybrid provides an IDNet 2 addressable initiating device
signaling line circuit (SLC) that supervises wiring connections and
the individual device communications status on the SLC. With 2
wire IDNet 2 SLCs, initiation, monitoring, and control devices such as
manual fire alarm stations, TrueAlarm sensors, control relays, and
sprinkler waterflow switches can communicate their identity and
status and receive fire alarm system control. Additional addressable
interface modules include circuit isolators, conventional IDC zone
adapters, and interface to other system circuits such as fans,
dampers, and elevator controls.
IDNet 2 addressable device operation
Each addressable device on the IDNet 2 communication channel
is continuously interrogated for status condition such as: normal,
off-normal, alarm, supervisory, or trouble. Both Class B and
Class A operation is available. Sophisticated poll and response
communication techniques ensure supervision integrity and enables
T-tapping of the circuits for Class B operation. Devices with LEDs
pulse the LED to indicate receipt of a communications poll and can
be turned on steady from the panel. With addressable devices,
the location and status of the connected device is monitored,
logged, and displayed on the operator interface LCD. For precise
identification, each device has its own 40-character custom label.