Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

ABB Advant Controller 31 40 & 50 Series

From:ABB | author:Mr.Chen | Time :2024-12-31 | 917 view: | 🔊 Click to read aloud ❚❚ | Share:

General setup rules

An ABB AC 31 system always includes an AC 31 central unit. There are three types of central units:

- The 40 series central unit, with a local inputs / outputs extensions interface

- The 50 series central unit, with a local inputs / outputs extensions interface

and a CS 31 bus interface

- The 90 series central unit, with a CS 31 bus interface

Each central unit incorporates a specific number of binary inputs / outputs and occasionally

analog. It is possible, depending on the central unit, to increase the number of inputs / outputs,

to add input / output extensions connected directly to the central units or remote input / output

units via the CS 31 twisted pair.



Central units with extensions

The 40 and 50 series. It’s possible to increase the number of inputs / outputs of the basic

central unit by adding up to 6 local extension units of either type, binary or analog (Figure 1-1).

2.2. Central units with CS 31 bus

The 50 and 90 series. It’s possible to increase the number of inputs / outputs of the basic

central unit by adding remote units. The central unit controlling the system is called the

MASTER central unit. The maximum bus length is 500 m without an amplifier and 2000 m with

3 amplifiers (1 NCB or NCBR unit enables bus amplification for 500 m).

The master central unit can manage up to 31 connection points called SLAVES, such as:

- A remote unit with extension possibilities: a maximum of 6 extension units comprising of a

maximum of 8 analog input channels and 8 analog output channels

- A simple remote unit (without extension) with analog or binary inputs / outputs

- A remote TCAD display

- An ABB NCSA-01 variable speed drive interface

- A high speed counter unit

- A central unit (50 series with extension possibilities, 90 series and the previous 30 series)

- Or any other device which disposes of a CS 31 communication (see Figure 1-2).

Comment:

A slave fitted solely with binary channels occupies 1 connection point.

A slave fitted with binary and analog channels occupies 2 connection points of the available 31.

The maximum number of remote ANALOG units depends on the MASTER central unit:

- 50 series: - a maximum of 31 remote analog input units

- a maximum of 31 remote analog output units

- a maximum of 15 extensible remote units (ICMK14F1) with analog input / output

extensions + 1 remote analog input / output unit (15 x 2 + 1 = 31)

- or a mixed binary / analog configuration within the previous limits

- 90 series: - a maximum of 12 remote analog input units

- a maximum of 12 remote analog output units

- or a maximum of 12 slaves with analog extensions

Operation of the 40 and 50 series central units

3.1. Functional diagram

The 40 and 50 series central units memory is composed of two distinct areas:

- A SRAM memory where the user program and data is loaded.

- A Flash EPROM memory which contains:

- a backup of the user program with the program constants,

- the configuration data,

- and the system program protected against access from the user program.

An incorporated battery, which is available only in the 50 series, also enables the backup of

internal variables.

The user program is a set of universal functions conceived by the constructor to cover all

applications and ensure all the basic PLC functions. It is developed with the AC31GRAF

software. After being translated into instructions understable by the central unit it is loaded in

RUN or STOP mode into the SRAM and then saved from the SRAM to the Flash EPROM.

Thereby, at each program launch the user program, saved in the Flash EPROM, is copied to

the SRAM for processing by the microprocessor (Figure 1-3).

The structure of the system program memory, the user program, the inputs / outputs and

internal variables are described in the annex (mapping).

Program execution

The central unit microprocessor ensures the cyclic execution of the system as shown in

Figure 1-4.

The internal processing:

- PLC monitoring and control

- and processing requests from the terminal operator,

is executed in parallel with the previously described cycle.

The main program is processed sequentially. It may call up to a maximum of 12 sub-programs.

  • Beckhoff EL3692-0030 | EtherCAT Terminal, 2-channel analog input, resistance
  • Beckhoff EL3692 | EtherCAT Terminal, 2-channel analog input, resistance
  • Beckhoff EL3681-0030 | EtherCAT Terminal, 1-channel analog input, multimeter
  • Beckhoff EL3681 | EtherCAT Terminal, 1-channel analog input, multimeter
  • Beckhoff EL3632 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer, 16 bit, 50 ksps
  • Beckhoff EL3621-0020 | EtherCAT Terminal, 1-channel analog input
  • Beckhoff EL3612-0020 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff EL3612 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff EL3602-0020 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3602-0010 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3602-0002 | EtherCAT Terminal, 2-channel analog input
  • Beckhoff EL3602 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3483-0060 | EtherCAT Terminal, 3-channel analog input, mains monitor
  • Beckhoff EL3483 | EtherCAT Terminal, 3-channel analog input, mains monitor
  • Beckhoff EL3475-0200 | EtherCAT Terminal, 12-channel analog input, 4-port, multi-function
  • Beckhoff EL3475 | EtherCAT Terminal, 12-channel analog input, 4-port, multi-function
  • Beckhoff EL3453-0120 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3453-0100 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3453-0090 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3453-0030 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3453-0020 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3453 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3446-0011 | EtherCAT Terminal, 6-channel analog input, current
  • Beckhoff EL3446 | EtherCAT Terminal, 6-channel analog input, current
  • Beckhoff EL3444 | EtherCAT Terminal, 4-channel analog input, current, 10 A AC/DC
  • Beckhoff EL3443-0020 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3443-0013 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3443-0011 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3443-0010 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3443 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3423 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3403-0333 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3403-0111 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3403-0100 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3403-0026 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3403-0010 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff EL3403 | EtherCAT Terminal, 3-channel analog input, power measurement
  • Beckhoff ED3362-0100 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ED3362 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ED3361-0100 | EtherCAT Terminal, 1-channel analog input, measuring bridge
  • Beckhoff ED3361 | EtherCAT Terminal, 1-channel analog input, measuring bridge
  • Beckhoff EL3356-0090 | EtherCAT Terminal, 1-channel analog input, measuring bridge
  • Beckhoff EL3356-0030 | EtherCAT Terminal, 1-channel analog input, measuring bridge
  • Beckhoff EL3356-0020 | EtherCAT Terminal, 1-channel analog input, measuring bridge
  • Beckhoff EL3356-0010 | EtherCAT Terminal, 1-channel analog input, measuring bridge
  • Beckhoff EL3356 | EtherCAT Terminal, 1-channel analog input, measuring bridge
  • Beckhoff EL3351 | EtherCAT Terminal, 1-channel analog input, measuring bridge
  • Beckhoff EL3318 | EtherCAT Terminal, 8-channel analog input, temperature
  • Eaton MPNC4N3LEAXX2F Magnum low voltage power circuit breaker
  • Eaton MPN6503HEAXX2Q Magnum low voltage power circuit breaker
  • Eaton SPN6204XEAXX2F Magnum low voltage power circuit breaker
  • ABB Vishay ESTA Phao 4/3 50uF 4kV 301kVAr 3-Phase Power Capacitor 3BHL000359P0001
  • Basler Electric Directional Power Relay BE1-320/UD3FE1PC0N0F
  • Basler Electric BE1-87T Transformer Differential Relay E1EA1KD0S0F
  • Basler Electric BE1-87T Power Solid State Relay E1E A1K C0N1F
  • Basler Electric BE1-87TE1EA1JC0S0F Transformer Differential Relay Module
  • Basler Electric KR7F VOLTAGE REGULATOR 9116200100
  • Basler Electric AEC63-7 ANALOG EXCITATION CONTROLLER
  • Basler Electric BE1-81O/UT3EE1KA7N1F / BE181OUT3EE1KA7N1F Digital Frequency Relay
  • Basler Electric BE1-BPR Breaker Protection Relay
  • Basler Electric SSR 125-9 1256 00 102 Static Voltage Regulator
  • Basler Electric MVC 112 Manual Voltage Control
  • Basler Electric 9321000102 Power System Products
  • Basler Electric RA-70-MDCT7 / RA70MDCT7 Microprocessor-Based Reference Adjuster
  • ACA1300-60GM | Basler Electric | Gige Camera, 12VDC, 2W, (UPP)
  • Basler Electric 6427C85G01 / 6427C85G01
  • Basler Electric 6965D05G01 / 6965D05G01
  • Basler Electric BE1-5127R M1E Z1P B0C0F / BE15127RM1EZ1PB0C0F Time Overcurrent Relay
  • Basler Electric BE127 A3EC1JA0N5F Under Voltage Relay
  • Basler Electric BE1-11-G6D1M1J1P0E000 / BE111G6D1M1J1P0E000 Protection System delivers
  • Basler Electric B3E-E1P-A0N0F Solid State Protective Relay
  • Basler Electric P/N: 9 1210 00 106 MANUAL VOLTAGE CONTROL 120/240VAC 50-320Hz
  • Beckhoff EL3314-0092 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3314-0090 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3314-0090 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3314-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3314-0010 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3314-0002 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3314 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3312 | EtherCAT Terminal, 2-channel analog input, temperature
  • Beckhoff EL3311 | EtherCAT Terminal, 1-channel analog input, temperature, thermocouple
  • Beckhoff EL3255 | EtherCAT Terminal, 5-channel analog input, potentiometer
  • Beckhoff ED3274 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3218 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff EL3214-0090 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3214 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3208-0010 | EtherCAT Terminal, 8-channel analog input, temperature, RTD (Pt1000, NTC), 16 bit
  • Beckhoff EL3208 | EtherCAT Terminal, 8-channel analog input, temperature, RTD (Pt100), 16 bit
  • Beckhoff EL3204-0200 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff EL3204-0162 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff EL3204 | EtherCAT Terminal, 4-channel analog input, temperature, RTD (Pt100), 16 bit
  • Beckhoff EL3202-0030 | EtherCAT Terminal, 2-channel analog input, temperature
  • Beckhoff EL3202-0020 | EtherCAT Terminal, 2-channel analog input, temperature
  • Beckhoff EL3202-0010 | EtherCAT Terminal, 2-channel analog input, temperature
  • Beckhoff EL3202 | EtherCAT Terminal, 2-channel analog input, temperature
  • Beckhoff EL3201-0030 | EtherCAT Terminal, 1-channel analog input, temperature
  • Beckhoff EL3201-0020 | EtherCAT Terminal, 1-channel analog input, temperature
  • Beckhoff EL3201-0010 | EtherCAT Terminal, 1-channel analog input, temperature
  • Beckhoff EL3201 | EtherCAT Terminal, 1-channel analog input, temperature
  • Beckhoff EL3184 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff EL3182 | EtherCAT Terminal, 2-channel analog input, current, 0/4…20 mA
  • Beckhoff EL3174-0090 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff EL3174-0042 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff EL3174-0032 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff EL3174-0030 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff EL3174-0002 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff EL3164 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff EL3162 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3161 | EtherCAT Terminal, 1-channel analog input, voltage
  • Beckhoff EL3154 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff EL3152 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff EL3151 | EtherCAT Terminal, 1-channel analog input, current
  • Beckhoff EL3144 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff EL3142-0010 | EtherCAT Terminal, 2-channel analog input
  • Basler Electric PRP320 Motor Pull-out Relay
  • Basler Electric SSE-N 250-9 KW Shunt Exciter Regulator Assembly
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50-51B-107
  • Basler Electric MVC 108 9 0370 00 102 Manual Voltage Controller ID: M32054
  • Basler Electric BE1-46N-G1E-B8P-B0N0F / BE146NG1EB8PB0N0F Negative Sequence Overcurrent Relay
  • Basler Electric UFOV 260 A Under Frequency / Over Voltage Protective Module
  • Basler Electric LEROY SOMER DECS-100 9287500132 DIGITAL EXCITATION CONTROL SYSTE
  • Basler Electric BE1-25 M1EA6OA5S0F SYNC-CHECK RECLOSING RELAY
  • Basler Electric SCA1300-32GM CCD CAMERA HF35HA-1B LENS WITH CYLINDER ENCLOSU
  • Basler Electric BA1-27 A3GC2JA0N5F / BA127A3GC2JA0N5F
  • Basler Electric 9261500101 Radio Frequency Interface
  • Basler Electric 9 2849 00 101 Decs Power Module
  • Basler Electric 9 2007 00 100 Current Boost System Cbs 305
  • Basler Electric 90 88800 102 VERI SYNC RELAY PRS 250